1. Package Contents
Before starting installing the Converter, verify the following parts
in the package:
● MediaConverterChassisx1
● User'sManualx1
● MountingAccessory(for10/19”ChassisShelf)x1
● RubberFeetx4
● ACPowerCordx1
If any of these are missing or damaged, please contact your
dealer immediately; if possible, retain the carton including the
original packing material, and use them again to repack the
productincasethereisaneedtoreturnittousforrepair.
3. Media Converter Chassis Front Panel
Figures 3-1, 3-2 and 3-3 show a front panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
Figure 3-1 MC-700 Front Panel
Figure 3-2 MC-1500 Front Panel
Figure 3-3 MC-1500R / 1500R48 Front Panel
6. Installing the Media Converter Chassis
6.1 Installing Media Converter Chassis to 10/19-inch
Wire Closet Rack
» Placefourscrewsthroughmountingearsoneachside.
» Locate Converter Chassis at 10/19-inch mounting rails and
screwupthefrontbrackets.
» Set Main power switch at “OFF” position before connecting
thepowercord.
Figure 6-1 InstallingMediaChassisinWireClosetRails
5. Media Converter Chassis Rear Panel
Figure 5-1, 5-2 and 5-3 show a rear panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
TherearpaneloftheMC-700comeswithonefan,oneON/OFF
switch and a power inlet that accept 100~240V AC, 50/60Hz
powerinput.
Figure 5-1 MC-700 Rear Panel
The rear panel of the MC-1500 comes with two fans, one
ON/OFF switch and a power inlet that accept 100~240V AC,
50/60Hzpowerinput.
Figure 5-2 MC-1500 Rear Panel
2. Product Features
● Highquality10"
/
19”Rack-mountableChassisinstallation
● Supportsuptoseven(7)/fteen(15)hot-swappablemedia
converters
● Onefan brings the air-ow for system cooling,and LED indi-
catorsforsystemandfanstatus(MC-700)
● Two fans bring the air-ow for an effective system cooling,
and LED indicators for system and fan status (MC-1500 /
1500R/1500R48)
● Thepowerslotatrearpanelforredundantpowersupportwith
option of 100~240V AC or -48V DC supplies (MC-1500R /
1500R48)
● Baypowerisolationtoensureeachbayiselectricallyisolated
from each other
● Supportsmultipleconverters with 10/100/1000Mbps, copper,
ber,single/multi-modeST/SC/SFPconnectors
● Reduces the effort of converter maintenance and manage-
ment,anddiagnosesthestatusatonetime
● Cost-effective,easytoinstall
4. LED Indicators
MC-700
Printing
LED
Status
Description
PWR
ON Thechassisispowered.
OFF
Thechassisisnotpoweredorpower
fails,iftheACoutletiswith100~240V
ACvoltage.Pleaseconsultyourlocal
dealerifpowerfails.
Fan
ON Thefanisfunctional.
OFF
Thefanisnotpoweredorit
malfunctionsifthefanLEDremainsoff
whilepowerison.Pleaseconsultyour
localdealertoreplacethefan.
MC-1500 Series
Printing
LED
Status
Description
PWR
ON Thechassisispowered.
OFF
Thechassisisnotpoweredorpower
fails.
FanA/
FanB
ON Thefanisfunctional.
OFF
Thefanisnotpoweredoritmalfunctions
ifthefanLEDremainsoffwhilepower
ison.Pleaseconsultyourlocaldealer
toreplacethefan.
TherearpaneloftheMC-1500R/1500R48.
Figure 5-3 MC-1500R / 1500R48 Rear Panel
Note
1. TheMC-1500Risshippedwithone100~240V
ACpowersupplymodule(MC-15RPS130).
2. TheMC-1500R48isshippedwithone-48VDC
powersupplymodule(MC-15RPS48).
Power
Notice
1. Thedeviceisapower-requireddevice,
meaning,itwillnotworktillitispowered.
Ifyournetworksshouldbeactiveallthe
time,pleaseconsiderusingaproperUPS
(UninterruptedPowerSupply)foryourdevice.
Itwillpreventyoufromnetworkdatalossor
networkdowntime.
2. Insomeareas,installingasurgesuppression
devicemayalsohelptoprotectyourchassis
frombeingdamagedbyunregulatedsurgeor
currenttotheconverterorthepoweradapter.
Rack Mount Instructions
A)ElevatedOperatingAmbient-Ifinstalledinaclosedormulti-
unit rack assembly, the operating ambient temperature of
the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum
ambienttemperature(Tma)speciedbythemanufacturer.
B)Reduced Air Flow - Installation of the equipment in a rack
shouldbesuch thattheamount ofairow requiredforsafe
operationoftheequipmentisnotcompromised.
C)Mechanical Loading - Mounting of the equipment in the rack
should be such that a hazardous condition is not achieved
duetounevenmechanicalloading.
D)Circuit Overloading - Consideration should be given to the
connection of the equipment to the supply circuit and the
effect that overloading of the circuits might have on over-
current protection and supply wiring. Appropriate consider-
ation of equipment nameplate ratings should be used when
addressingthisconcern.
E)Reliable Earthing - Reliable earthing of rack-mounted equip-
ment should be maintained. Particular attention should be
given to supply connections other than direct connections to
thebranchcircuit(e.g.useofpowerstrips)."