1. Package Contents
Before starting installing the Converter, verify the following parts
in the package:
● MediaConverterChassisx1
● User'sManualx1
● MountingAccessory(for10/19”ChassisShelf)x1
● RubberFeetx4
● ACPowerCordx1
If any of these are missing or damaged, please contact your
dealer immediately; if possible, retain the carton including the
original packing material, and use them again to repack the
productincasethereisaneedtoreturnittousforrepair.
3. Media Converter Chassis Front Panel
Figures 3-1, 3-2 and 3-3 show a front panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
Figure 3-1 MC-700 Front Panel
Figure 3-2 MC-1500 Front Panel
Figure 3-3 MC-1500R / 1500R48 Front Panel
6. Installing the Media Converter Chassis
6.1 Installing Media Converter Chassis to 10/19-inch
Wire Closet Rack
» Placefourscrewsthroughmountingearsoneachside.
» Locate Converter Chassis at 10/19-inch mounting rails and
screwupthefrontbrackets.
» Set Main power switch at “OFF” position before connecting
thepowercord.
Figure 6-1 InstallingMediaChassisinWireClosetRails
5. Media Converter Chassis Rear Panel
Figure 5-1, 5-2 and 5-3 show a rear panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
TherearpaneloftheMC-700comeswithonefan,oneON/OFF
switch and a power inlet that accept 100~240V AC, 50/60Hz
powerinput.
Figure 5-1 MC-700 Rear Panel
The rear panel of the MC-1500 comes with two fans, one
ON/OFF switch and a power inlet that accept 100~240V AC,
50/60Hzpowerinput.
Figure 5-2 MC-1500 Rear Panel
2. Product Features
● Highquality10"
/
19”Rack-mountableChassisinstallation
● Supportsuptoseven(7)/fteen(15)hot-swappablemedia
converters
● Onefan brings the air-ow for system cooling,and LED indi-
catorsforsystemandfanstatus(MC-700)
● Two fans bring the air-ow for an effective system cooling,
and LED indicators for system and fan status (MC-1500 /
1500R/1500R48)
● Thepowerslotatrearpanelforredundantpowersupportwith
option of 100~240V AC or -48V DC supplies (MC-1500R /
1500R48)
● Baypowerisolationtoensureeachbayiselectricallyisolated
from each other
● Supportsmultipleconverters with 10/100/1000Mbps, copper,
ber,single/multi-modeST/SC/SFPconnectors
● Reduces the effort of converter maintenance and manage-
ment,anddiagnosesthestatusatonetime
● Cost-effective,easytoinstall
4. LED Indicators
MC-700
Printing
LED
Status
Description
PWR
ON Thechassisispowered.
OFF
Thechassisisnotpoweredorpower
fails,iftheACoutletiswith100~240V
ACvoltage.Pleaseconsultyourlocal
dealerifpowerfails.
Fan
ON Thefanisfunctional.
OFF
Thefanisnotpoweredorit
malfunctionsifthefanLEDremainsoff
whilepowerison.Pleaseconsultyour
localdealertoreplacethefan.
MC-1500 Series
Printing
LED
Status
Description
PWR
ON Thechassisispowered.
OFF
Thechassisisnotpoweredorpower
fails.
FanA/
FanB
ON Thefanisfunctional.
OFF
Thefanisnotpoweredoritmalfunctions
ifthefanLEDremainsoffwhilepower
ison.Pleaseconsultyourlocaldealer
toreplacethefan.
TherearpaneloftheMC-1500R/1500R48.
Figure 5-3 MC-1500R / 1500R48 Rear Panel
Note
1. TheMC-1500Risshippedwithone100~240V
ACpowersupplymodule(MC-15RPS130).
2. TheMC-1500R48isshippedwithone-48VDC
powersupplymodule(MC-15RPS48).
Power
Notice
1. Thedeviceisapower-requireddevice,
meaning,itwillnotworktillitispowered.
Ifyournetworksshouldbeactiveallthe
time,pleaseconsiderusingaproperUPS
(UninterruptedPowerSupply)foryourdevice.
Itwillpreventyoufromnetworkdatalossor
networkdowntime.
2. Insomeareas,installingasurgesuppression
devicemayalsohelptoprotectyourchassis
frombeingdamagedbyunregulatedsurgeor
currenttotheconverterorthepoweradapter.
Rack Mount Instructions
A)ElevatedOperatingAmbient-Ifinstalledinaclosedormulti-
unit rack assembly, the operating ambient temperature of
the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum
ambienttemperature(Tma)speciedbythemanufacturer.
B)Reduced Air Flow - Installation of the equipment in a rack
shouldbesuch thattheamount ofairow requiredforsafe
operationoftheequipmentisnotcompromised.
C)Mechanical Loading - Mounting of the equipment in the rack
should be such that a hazardous condition is not achieved
duetounevenmechanicalloading.
D)Circuit Overloading - Consideration should be given to the
connection of the equipment to the supply circuit and the
effect that overloading of the circuits might have on over-
current protection and supply wiring. Appropriate consider-
ation of equipment nameplate ratings should be used when
addressingthisconcern.
E)Reliable Earthing - Reliable earthing of rack-mounted equip-
ment should be maintained. Particular attention should be
given to supply connections other than direct connections to
thebranchcircuit(e.g.useofpowerstrips)."