User’s Manual of LRP-422CST Trademarks Copyright © PLANET Technology Corp. 2015. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
User’s Manual of LRP-422CST TABLE OF CONTENTS 1. INTRODUCTION.................................................................................................................. 10 1.1 Packet Contents .........................................................................................................................................10 1.2 Product Description ...................................................................................................................................11 1.
User’s Manual of LRP-422CST 4.1 Main Web Page ...........................................................................................................................................52 4.1.1 Save Button .........................................................................................................................................................54 4.1.2 Configuration Manager ..........................................................................................................................
User’s Manual of LRP-422CST 4.3.11 SFP Module Information ..................................................................................................................................108 4.3.11.1 SFP Module Status ................................................................................................................................108 4.3.11.2 SFP Module Detail Status ...................................................................................................................... 110 4.
User’s Manual of LRP-422CST 4.7.2 IGMP Snooping .................................................................................................................................................174 4.7.2.1 IGMP Setting ...........................................................................................................................................178 4.7.2.2 IGMP Querier Setting ..........................................................................................................................
User’s Manual of LRP-422CST 4.8.5.2 Properties ................................................................................................................................................223 4.8.5.3 Telephony OUI MAC Setting....................................................................................................................225 4.8.5.4 Telephony OUI Port Setting .....................................................................................................................226 4.
User’s Manual of LRP-422CST 4.9.8.5 Rate Limit ................................................................................................................................................277 4.9.9 IP Source Guard ................................................................................................................................................279 4.9.9.1 Port Settings .............................................................................................................................
User’s Manual of LRP-422CST 4.13.4 IPv6 Ping Test..................................................................................................................................................338 4.14 RMON.......................................................................................................................................................339 4.14.1 RMON Statistics .............................................................................................................................
User’s Manual of LRP-422CST 1. INTRODUCTION Thank you for purchasing PLANET Industrial 4-port Coax + 2-port 10/100/1000T + 2-port 100/1000X SFP Long Reach PoE over Coaxial Managed Switch. “LRP Managed Switch” is used as an alternative name in this user’s manual. 1.1 Packet Contents Open the box of the LRP Managed Switch and carefully unpack it.
User’s Manual of LRP-422CST 1.2 Product Description PLANET Long Reach PoE Solution enables all enterprises and network service providers to set up an IP infrastructure in a remote location where 802.3af/at PoE compliant powered devices can receive both data and power via PLANET switches, and PLANET LRP extenders and injectors over a long distance but not limited to the normal 100 meters.
User’s Manual of LRP-422CST Multi-channel Long Reach Power over Ethernet To support the enterprises in easily building a multi-channel and centrally-controlled Long Reach PoE system, the LRP-422CST works with the Long Reach PoE Extenders, LRP-101CE, via its 4 BNC ports being the Long Reach PoE injectors for all connected LRP Extenders.
User’s Manual of LRP-422CST Daisy-chaining Multiple Nodes PLANET Long Reach PoE solution can easily build a power system for centrally-controlled IP cameras in a high availability network infrastructure. It gives users the flexibility to expand small area network with BNC T-connector for sharing four nodes per port when needed, making the LRP-422CST with 4 BNC Long Reach PoE Ports an ideal support for up to 16 IP cameras.
User’s Manual of LRP-422CST Scheduled Power Recycling The LRP-422CST allows each of the connected PoE IP cameras or PoE wireless access points via the LRP-101CE Long Reach PoE Extender to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or wireless AP crash resulting from buffer overflow.
User’s Manual of LRP-422CST Robust Layer 2 Features The LRP-422CST can be programmed for advanced switch management functions such as dynamic port link aggregation, 802.1Q VLAN and Q-in-Q VLAN, Multiple Spanning Tree Protocol (MSTP), Loop and BPDU Guard, IGMP Snooping, and MLD Snooping. Via the link aggregation, the LRP-422CST allows the operation of a high-speed trunk to combine with multiple ports such as an 8Gbps fat pipe, and supports fail-over as well.
User’s Manual of LRP-422CST Flexibility and Long-distance Extension Solution The LRP-422CST provides two Gigabit TP interfaces supporting 10/100/1000BASE-T RJ45 copper to be connected with surveillance network devices such as NVR, Video Streaming Server or NAS to facilitate surveillance management.
User’s Manual of LRP-422CST 1.3 How to Use This Manual This User Manual is structured as follows: Section 2, INSTALLATION The section explains the functions of the Switch and how to physically install the LRP Managed Switch. Section 3, SWITCH MANAGEMENT The section contains the information about the software function of the LRP Managed Switch. Section 4, WEB CONFIGURATION The section explains how to manage the LRP Managed Switch by Web interface.
User’s Manual of LRP-422CST Layer 2 Features ■ Prevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex) ■ High performance Store and Forward architecture, broadcast storm control and runt/CRC filtering that eliminates erroneous packets to optimize the network bandwidth ■ Supports VLAN IEEE 802.1Q tagged VLAN Provider Bridging (VLAN Q-in-Q, IEEE 802.
User’s Manual of LRP-422CST IEEE 802.
User’s Manual of LRP-422CST 1.5 Product Specifications Model LRP-422CST Hardware Specifications Copper Ethernet Interfaces Fiber Optic 2 x 10/100/1000BASE-T RJ45 Auto-negotiation/Auto-MDI/MDI-X 2 x 100/1000BASE-X SFP slot Supports 100/1000Mbps dual mode and DDM Jumbo Frame 10Kbytes with GE1 to GE4 Connectivity 4 x BNC female connectors Long Reach PoE over coaxial PSE (Power Source Equipment) BNC center pole : DC+/Hi BNC shield : DC -/Lo Power Output Per port 48~56V DC, 36 watts (max.
User’s Manual of LRP-422CST Extender Console 1 x RS232-to-RJ45 serial port (115200, 8, N, 1) Switch Architecture Store-and-Forward Switch Fabric 8.8Gbps/non-blocking Address Table 8K entries Shared Data Buffer 4.1 megabits Flow Control Reset Button IEEE 802.
User’s Manual of LRP-422CST Up to 256 multicast groups MLD Snooping MLD (v1/v2) Snooping, up to 256 multicast groups Access Control List IPv4/IPv6 IP-based ACL/MAC-based ACL 8 mapping IDs to 8 level priority queues - Port number - 802.1p priority QoS - 802.1Q VLAN tag - DSCP field in IP packet Traffic classification based, strict priority and WRR IEEE 802.
User’s Manual of LRP-422CST IEEE 802.1p Class of Service IEEE 802.1Q VLAN tagging IEEE 802.1X Port Authentication Network Control IEEE 802.
User’s Manual of LRP-422CST 2. INSTALLATION This section describes the hardware features and installation of the LRP Managed Switch with DIN-rail or wall mount. For easier management and control of the LRP Managed Switch, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators. Before connecting any network device to the LRP Managed Switch, please read this chapter completely. 2.1 Hardware Description 2.1.
User’s Manual of LRP-422CST 2.1.2 Front Panel ■ Long Reach PoE BNC Interface BNC female port, 5C2V/RG6 75Ω coaxial cable: Up to 1 kilometer. ■ Gigabit TP Interface 10/100/1000BASE-T Copper, RJ45 Twisted-pair: Up to 100 meters. ■ 100/1000BASE-X SFP Slots Each of the SFP (Small Form-factor Pluggable) slots supports dual-speed, 1000BASE-SX/LX or 100BASE-FX - For 1000BASE-SX/LX SFP transceiver module: From 550 meters (multi-mode fiber) to 10/30/50/70/120 kilometers (single-mode fiber).
User’s Manual of LRP-422CST provides rich diagnostic information including IP Address setting, factory reset, port management, link status and system setting. Users can use the attached DB9 to RJ45 console cable in the package and connect to the console port on the device. After the connection, users can run any terminal emulation program (Hyper Terminal, ProComm Plus, Telix, Winterm and so on) to enter the startup screen of the device.
User’s Manual of LRP-422CST Blinking To indicate that the switch is actively sending or receiving data over that port. 1000 Orange Lights To indicate that the port is operating at 1000Mbps. Lights If LNK/ACT LED lights up, it indicates that the port is operating at 10/100Mbps. Off If LNK/ACT LED is off, it indicates that the port is linkdown.
User’s Manual of LRP-422CST ■ 1000BASE-SX/LX SFP Interfaces (GE3 to GE4) LED Color LNK/ACT Green Function Lights 1000 Orange To indicate the link through that port is successfully established. Blinking To indicate that the switch is actively sending or receiving data over that port. Lights To indicate that the port is operating at 1000Mbps. Lights If LNK/ACT LED lights up, it indicates that the port is operating at 100Mbps. Off If LNK/ACT LED is off, it indicates that the port is link down. 2.
User’s Manual of LRP-422CST LRP-422CST Positive (+) Pin Negative (-) Pin Pin 1/5 Pin 2/6 1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG. 2. When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock. 2.1.5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle (3 & 4) of the terminal block connector as the picture shows below.
User’s Manual of LRP-422CST 2.2 Installing the LRP Managed Switch This section describes how to install your LRP Managed Switch and make connections to the LRPl Managed Switch. Please read the following topics and perform the procedures in the order being presented. To install your LRP Managed Switch on a desktop or shelf, simply complete the following steps. In this paragraph, we will describe how to install the LRP Managed Switch and the installation points attended to it. 2.2.1 Installation Steps 1.
User’s Manual of LRP-422CST 2.2.2 DIN-rail Mounting This section describes how to install the LRP Managed Switch. There are two methods to install the LRP Managed Switch -DIN-rail mounting and wall-mount plate mounting. Please read the following topics and perform the procedures in the order being presented. Follow all the DIN-rail installation steps as shown in the example. Step 1: Screw the DIN-rail on the LRP Managed Switch. Step 2: Lightly slide the DIN-rail into the track.
User’s Manual of LRP-422CST 32
User’s Manual of LRP-422CST Step 3: Check whether the DIN-rail is tightly on the track. Please refer to the following procedures to remove the LRP Managed Switch from the track. Step 4: Lightly remove the DIN-rail from the track. 2.2.3 Wall-mount Plate Mounting To install the LRP Managed Switch on the wall, please follow the instructions below. Follow all the DIN-rail installation steps as shown in the example.
User’s Manual of LRP-422CST Step 1: Remove the DIN-rail from the LRP Managed Switch. Use the screwdriver to loosen the screws to remove the DIN-rail. Step 2: Place the wall-mount plate on the rear panel of the LRP Managed Switch. Step 3: Use the screwdriver to screw the wall-mount plate on the LRP Managed Switch. Step 4: Use the hook holes at the corners of the wall-mount plate to hang the LRP Managed Switch on the wall. Step 5: To remove the wall-mount plate, reverse the steps above.
User’s Manual of LRP-422CST 2.2.4 Cabling 10/100/1000BASE-T All 10/100/1000BASE-T ports come with auto-negotiation capability. They automatically support 1000BASE-T, 100BASE-TX and 10BASE-T networks. Users only need to plug a working network device into one of the 10/100/1000BASE-T ports, and then turn on the LRP Managed Switch. The port will automatically run in 10Mbps, 20Mbps, 100Mbps or 200Mbps and 1000Mbps or 2000Mbps after negotiating with the connected device.
User’s Manual of LRP-422CST 2.2.5 Installing the SFP transceiver The sections describe how to insert an SFP transceiver into an SFP slot. The SFP transceivers are hot-pluggable and hot-swappable. You can plug in and out the transceiver to/from any SFP port without having to power down the LRP Managed Switch as Figure 2-1 shows. Follow all the installation and removal of SFP transceiver steps as shown in the example.
User’s Manual of LRP-422CST MFB-TF20 100 LC Single Mode 20km 1550nm -40 ~ 75 degrees C Fast Ethernet Transceiver (100BASE-BX, Single Fiber Bi-directional SFP) Distance Wavelength (TX) Wavelength (RX) Operating Temp.
User’s Manual of LRP-422CST MGB-TLB40 1000 WDM(LC) Single Mode 40km 1550nm 1310nm -40 ~ 75 degrees C MGB-TLA60 1000 WDM(LC) Single Mode 60km 1310nm 1550nm -40 ~ 75 degrees C MGB-TLB60 1000 WDM(LC) Single Mode 60km 1550nm 1310nm -40 ~ 75 degrees C It is recommended to use PLANET SFP on the LRP Managed Switch. If you insert an SFP transceiver that is not supported, the LRP Managed Switch will not recognize it.
User’s Manual of LRP-422CST Figure 2-2 How to Pull Out the SFP Transceiver Never pull out the module without lifting up the lever of the module and turning it into a horizontal position. Directly pulling out the module could damage the module and the SFP module slot of the LRP Managed Switch.
User’s Manual of LRP-422CST 2.2.6 Installing the Long Reach PoE Communication The sections describe how to insert a coaxial cable into a BNC female port. You can plug in and out the coaxial cable to/from any BNC female port without having to power down the LRP Managed Switch.
User’s Manual of LRP-422CST Figure 2-3 How to insert the coaxial cable from LRP Managed Switch 4. Enable Long Reach Power over Ethernet function for the all LRP ports from WebUI 5. Check the LNK LED of the Long Reach Power over Ethernet interface on the front of the LRP Managed Switch. Ensure that the Long Reach Power over Ethernet interface is operating correctly. Remove the connected the Coaxial Cable 1. Make sure there is no network activity anymore. 2.
User’s Manual of LRP-422CST 3. Loosen the BNC male connector gently. 4. Pull out the coaxial cable gently. Figure 2-4 How to pull out the coaxial cable from LRP Managed Switch Never pull out the coaxial cable without disabling Long Reach Power over Ethernet function for the port from WebUI. Directly pulling out the coaxial cable could damage the Long Reach Ethernet coaxial extender and the BNC female connector of the LRP Managed Switch.
User’s Manual of LRP-422CST 1. The package contains eight warning stickers, which should be stuck on the coaxial cable connector before using PLANET LRP Managed Switch and LRP extender. If connected with non-PLANET LRP series extender equipment, it might cause damage to the equipment. 2. After the LRP PoE port is enabled, the pin center of the coaxial cable has electricity. Do not touch the pin center or connect this end to any non- PLANET LRP equipment.
User’s Manual of LRP-422CST 3. SWITCH MANAGEMENT This chapter explains the methods that you can use to configure management access to the LRP Managed Switch. It describes the types of management applications and the communication and management protocols that deliver data between your management device (workstation or personal computer) and the system. It also contains information about port connection options.
User’s Manual of LRP-422CST 3.2 Management Access Overview The LRP Managed Switch gives you the flexibility to access and manage it using any or all of the following methods: An administration console Web browser interface An external SNMP-based network management application The administration console and Web browser interface support are embedded in the LRP Managed Switch software and are available for immediate use. Each of these management methods has their own advantages.
User’s Manual of LRP-422CST 3.3 Administration Console The administration console is an internal, character-oriented, and command line user interface for performing system administration such as displaying statistics or changing option settings. Using this method, you can view the administration console from a terminal, personal computer, Apple Macintosh, or workstation connected to the LRP Managed Switch's console port.
User’s Manual of LRP-422CST You can change these settings, if desired, after you log on. This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port.
User’s Manual of LRP-422CST 3.5 SNMP-based Network Management You can use an external SNMP-based application to configure and manage the LRP Managed Switch, such as SNMP Network Manager, HP Openview Network Node Management (NNM) or What’s Up Gold. This management method requires the SNMP agent on the switch and the SNMP Network Management Station to use the same community string. This management method, in fact, uses two community strings: the get community string and the set community string.
User’s Manual of LRP-422CST If there are two LAN cards or above in the same administrator PC, choose a different LAN card by using the “Select Adapter” tool. 3. Press the “Refresh” button for the currently connected devices in the discovery list as the screen shows below: Figure 3-1-7: Planet Smart Discovery Utility Screen 1. This utility shows all necessary information from the devices, such as MAC Address, Device Name, firmware version and Device IP Subnet address.
User’s Manual of LRP-422CST 4. WEB CONFIGURATION This section introduces the configuration and functions of the Web-based management. About Web-based Management The LRP Managed Switch offers management features that allow users to manage the LRP Managed Switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer. The Web-based Management supports Internet Explorer 8.0.
User’s Manual of LRP-422CST 2. When the following login screen appears, please enter the default username "admin" with password “admin” (or the username/password you have changed via console) to login the main screen of LRP Managed Switch. The login screen in Figure 4-1-2 appears. Figure 4-1-2 Login screen Default User Name: admin Default Password: admin After entering the username and password, the main screen appears as Figure 4-1-3.
User’s Manual of LRP-422CST Now, you can use the Web management interface to continue the switch management or manage the LRP Managed Switch by Web interface. The Switch Menu on the left of the web page lets you access all the commands and statistics the LRP Managed Switch provides. It is recommended to use Internet Explore 8.0 or above to access LRP Managed Switch. The changed IP address takes effect immediately after clicking on the Save button.
User’s Manual of LRP-422CST State Disabled Down Link LRP Ports RJ45 Ports SFP Ports Main Menu Using the onboard Web agent, you can define system parameters, manage and control the LRP Managed Switch, and all its ports, or monitor network conditions. Via the Web-Management, the administrator can set up the LRP Managed Switch by selecting the functions those listed in the Main Function. The screen in Figure 4-1-5 appears.
User’s Manual of LRP-422CST 4.1.1 Save Button This save button allows save the running / startup / backup configuration or reset switch in default parameter. The screen in Figure 4-1-6 appears. Figure 4-1-6 Save Button Screenshot The page includes the following fields: Object Description Save Configuration to Click to save the configuration. For more detailed information, please refer to FLASH Restore to Default chapter 4.1.2 Click to reset switch in default parameter.
User’s Manual of LRP-422CST configuration file, which is called configuration save. To prevent illicit file upload and easier configuration, switch mandates the name of running configuration file to be running-config. Startup Configuration Refers to the configuration sequence used in switch startup. Startup configuration file stores in nonvolatile storage, corresponding to the so-called configuration save. If the device supports multi-config file, name the configuration file to be .
User’s Manual of LRP-422CST 3. Press the “Apply” button to save running configuration to start up configuration.
User’s Manual of LRP-422CST 4.2 System Use the System menu items to display and configure basic administrative details of the LRP Managed Switch. Under System the following topics are provided to configure and view the system information. This section has the following items: ■ System Information The switch system information is provided here. ■ IP Configurations Configure the switch-managed IP information on this page. ■ IPv6 Configuration Configure the switch-managed IPv6 information on this page.
User’s Manual of LRP-422CST The page includes the following fields: Object Description System Name Display the current system name System Location Display the current system location System Contact Display the current system contact MAC Address The MAC address of this LRP Managed Switch. IP Address The IP address of this LRP Managed Switch. Subnet Mask The subnet mask of this LRP Managed Switch. Gateway The gateway of this LRP Managed Switch.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Mode Indicates the IP address mode operation. Possible modes are: Static: Enable NTP mode operation. When enabling NTP mode operation, the agent forwards and transfers NTP messages between the clients and the server when they are not on the same subnet domain. DHCP: Enable DHCP client mode operation. Enable the DHCP client by checking this box. If DHCP fails and the configured IP address is zero, DHCP will retry.
User’s Manual of LRP-422CST Object Description DHCP State Display the current DHCP state. IP Address Display the current IP address. Subnet Mask Display the current subnet mask. Gateway Display the current gateway. DNS Server 1/2 Display the current DNS server. 4.2.3 IPv6 Configuration The IPv6 Configuration includes Auto Configuration, IPv6 Address and Gateway. The configured column is used to view or change the IPv6 configuration.
User’s Manual of LRP-422CST Gateway Provide the IPv6 gateway address of this switch. DHCPv6 Client To enable this LRP Managed Switch to accept a configuration from a Dynamic Host Configuration Protocol version 6 (DHCPv6) server. By default, the LRP Managed Switch does not perform DHCPv6 client actions. DHCPv6 clients request the delegation of long-lived prefixes that they can push to individual local hosts. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.2.4 User Configuration This page provides an overview of the current users and privilege type. Currently the only way to login as another user on the Web server is to close and reopen the browser. After the setup is completed, please press the “Apply” button to take effect. Please login Web interface with a new user name and password; the screens in Figure 4-2-6 & Figure 4-2-7 appear.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Username Display the current username Password Type Display the current password type Privilege Type Display the current privilege type Modify Click to modify the local user entry : Delete the current user 4.2.5 Time Settings 4.2.5.1 System Time Configure SNTP on this page. SNTP is an acronym for Simple Network Time Protocol, a network protocol for synchronizing the clocks of computer systems.
User’s Manual of LRP-422CST Object Description Enable SNTP Enabled: Enable SNTP mode operation. When enabling SNTP mode operation, the agent forwards and transfers SNTP messages between the clients and the server when they are not on the same subnet domain. Disabled: Disable SNTP mode operation. Manual Time To set time manually. Year - Select the starting Year. Month - Select the starting month. Day - Select the starting day. Hours - Select the starting hour.
User’s Manual of LRP-422CST Month - Select the starting month. Hours - Select the starting hour. Minutes - Select the starting minute. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.2.5.2 SNTP Server Settings The SNTP Server Configuration screens in Figure 4-2-10 & Figure 4-2-11 appear. Figure 4-2-10 SNTP Setup Page Screenshot The page includes the following fields: Object Description SNTP Server Address Type the IP address or domain name of the SNTP server Server Port Type the port number of the SNTP Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.2.6 Log Management The LRP Managed Switch log management is provided here. The local logs allow you to configure and limit system messages that are logged to flash or RAM memory. The default is for event levels 0 to 3 to be logged to flash and levels 0 to 6 to be logged to RAM.
User’s Manual of LRP-422CST Figure 4-2-13 Logging Information Page Screenshot The page includes the following fields: Object Description Logging Service Display the current logging service status 4.2.6.2 Local Log The switch system local log information is provided here. The local Log screens in Figure 4-2-14 & Figure 4-2-15 appear. Figure 4-2-14 Local Log Target Setting Page Screenshot The page includes the following fields: Object Description Target The target of the local log entry.
User’s Manual of LRP-422CST notice: Notice level of the normal but significant conditions for local log. info: Informational level of the informational messages for local log. debug: Debug level of the debugging messages for local log. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.2.6.3 Remote Syslog Configure remote syslog on this page. The Remote Syslog page allows you to configure the logging of messages that are sent to syslog servers or other management stations. You can also limit the event messages sent to only those messages below a specified level. The Remote Syslog screens in Figure 4-2-16 & Figure 4-2-17 appear.
User’s Manual of LRP-422CST crit: Critical level of the critical conditions for local log. error: Error level of the error conditions for local log. warning: Warning level of the warning conditions for local log. notice: Notice level of the normal but significant conditions for local log. info: Informational level of the informational messages for local log. debug: Debug level of the debugging messages for local log. Facility Local0~7: local user 0~7 Buttons : Click to apply changes.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Target The target of the log view entry. The following target types are supported: Buffered: Target the buffered of the log view. File: Target the file of the log view. Severity The severity of the log view entry. The following severity types are supported: emerg: Emergency level of the system unstable for log view. alert: Alert level of the immediate action needed for log view.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Target Display the current log target Severity Display the current log severity Category Display the current log category Total Entries Display the current log entries Figure 4-2-20 Logging Messages Page Screenshot The page includes the following fields: Object Description No.
User’s Manual of LRP-422CST 4.2.7 SNMP Management 4.2.7.1 SNMP Overview The Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of management information between network devices. It is part of the Transmission Control Protocol/Internet Protocol (TCP/IP) protocol suite. SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth.
User’s Manual of LRP-422CST 4.2.7.2 SNMP System Information Configure SNMP setting on this page. The SNMP System global setting screens in Figure 4-2-21 & Figure 4-2-22 appear. Figure 4-2-21 SNMP Global Setting Page Screenshot The page includes the following fields: Object Description Status Indicates the SNMP mode operation. Possible modes are: Enabled: Enable SNMP mode operation. Disabled: Disable SNMP mode operation. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.2.7.3 SNMP Community Configure SNMP Community on this page. The SNMP Community screens in Figure 4-2-23 & Figure 4-2-24 appear. Figure 4-2-23 Community Setting Page Screenshot The page includes the following fields: Object Description Community Name Indicates the community read/write access string to permit access to SNMP agent. The allowed string length is 0 to 16. Community Mode Indicates the SNMP community supported mode.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Community Name Display the current community type Group Name Display the current SNMP access group’s name View Name Display the current view name Access Right Display the current access type Delete : Delete the community entry 4.2.7.4 SNMP View Configure SNMPv3 view table on this page. The entry index keys are View Name and OID Subtree.
User’s Manual of LRP-422CST Buttons : Click to add a new view entry. Figure 4-2-23 SNMP View Table Status Page Screenshot The page includes the following fields: Object Description View Name Display the current SNMP view name Subtree OID Display the current SNMP subtree OID OID Mask Display the current SNMP OID mask View Type Display the current SNMP view type Action : Delete the view table entry.
User’s Manual of LRP-422CST 4.2.7.5 SNMP Access Group Configure SNMPv3 access group on this page. The entry index keys are Group Name, Security Model and Security Level. The SNMPv3 Access Group Setting screens in Figure 4-2-27 & Figure 4-2-28 appear. Figure 4-2-27 SNMPv3 Access Group Setting Page Screenshot The page includes the following fields: Object Description Group Name A string identifying the group name that this entry should belong to. The allowed string length is 1 to 16.
User’s Manual of LRP-422CST : Check to delete the entry.
User’s Manual of LRP-422CST 4.2.7.6 SNMP User Configure SNMPv3 users table on this page. Each SNMPv3 user is defined by a unique name. Users must be configured with a specific security level and assigned to a group. The SNMPv3 group restricts users to a specific read, write, and notify view. The entry index key is User Name. The SNMPv3 User Setting screens in Figure 4-2-29 & Figure 4-2-30 appear.
User’s Manual of LRP-422CST Encryption Protocol Indicates the privacy protocol that this entry should belong to. Possible privacy protocol are: None: None privacy protocol. DES: An optional flag to indicate that this user using DES authentication protocol. Encryption Key A string identifying the privacy pass phrase. The allowed string length is 8 to 16. Buttons : Click to add a new user entry.
User’s Manual of LRP-422CST 4.2.7.7 SNMPv1, 2 Notification Recipients Configure SNMPv1 and 2 notification recipients on this page. The SNMPv1, 2 Notification Recipients screens in Figure 4-2-31 & Figure 4-2-32 appear. Figure 4-2-31 SNMPv1, 2 Notification Recipients Page Screenshot The page includes the following fields: Object Description Server Address Indicates the SNMP trap destination address. It allows a valid IP address in dotted decimal notation ('x.y.z.w').
User’s Manual of LRP-422CST The page includes the following fields: Object Description Server Address Display the current server address SNMP Version Display the current SNMP version Notify Type Display the current notify type Community Name Display the current community name UDP Port Display the current UDP port Time Out Display the current time out Retries Display the current retry times Action : Delete the SNMPv1, 2 host entry. 4.2.7.
User’s Manual of LRP-422CST : Click to add a new SNMPv3 host entry. Figure 4-2-34 SNMPv3 Host Status Page Screenshot The page includes the following fields: Object Description Server Address Display the current server address Notify Type Display the current notify type User Name Display the current user name UDP Port Display the current UDP port Time Out Display the current time out Retries Display the current retry times Action : Delete the SNMPv3 host entry 4.2.7.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Engine ID An octet string identifying the engine ID that this entry should belong to. The string must contain an even number between 10 and 64 hexadecimal digits, but all-zeros and all-'F's are not allowed. Buttons : Click to apply changes.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Remote IP Address Indicates the SNMP remote engine ID address. It allows a valid IP address in dotted decimal notation ('x.y.z.w'). Engine ID An octet string identifying the engine ID that this entry should belong to.
User’s Manual of LRP-422CST 4.3 Port Management Use the Port Menu to display or configure the LRP Managed Switch's ports.
User’s Manual of LRP-422CST Disabled – Shut down the port manually. Speed Select any available link speed for the given switch port. Draw the menu bar to select the mode. Duplex Auto - Setup Auto negotiation. Auto-10M - Setup 10M Auto negotiation. Auto-100M - Setup 100M Auto negotiation. Auto-1000M - Setup 1000M Auto negotiation. Auto-10/100M - Setup 10/100M Auto negotiation. 10M - Setup 10M Force mode. 100M - Setup 100M Force mode. 1000M - Setup 1000M Force mode.
User’s Manual of LRP-422CST Object Description Port This is the logical port number for this row Description Click to indicate the port name Enable State Display the current port state Link Status Display the current link status Speed Display the current speed status of the port Duplex Display the current duplex status of the port Flow Control Configuration Display the current flow control configuration of the port Flow Control Status Display the current flow control status
User’s Manual of LRP-422CST Figure 4-3-2B Port Status Page Screenshot The page includes the following fields: Object Description Port This is the logical port number for this row Description Click to indicate the port name Enable State Display the current port state Link Status Display the current link status 4.3.3 Port Counters This page provides an overview of traffic and trunk statistics for all switch ports.
User’s Manual of LRP-422CST Mode Select port counters mode. Option: All Interface Ether-link RMON Figure 4-3-4 Interface Counters Page Screenshot Object Description Received Octets The total number of octets received on the interface, including framing characters. Received Unicast The number of subnetwork-unicast packets delivered to a higher-layer protocol.
User’s Manual of LRP-422CST Transmit Unknown The total number of packets that higher-level protocols requested is transmitted Unicast Packets to a subnetwork-unicast address, including those that were discarded or not sent. Transmit Discarded The number of inbound packets which is chosen to be discarded even though no Packets errors have been detected to prevent from being delivered to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.
User’s Manual of LRP-422CST frames received with frame-too-long or frame-too-short error. Single Collision Frames Multiple Collision Frames Deferred Transmissions Late Collision The number of successfully transmitted frames for which transmission is inhibited by exactly one collision. A count of successfully transmitted frames for which transmission is inhibited by more than one collision.
User’s Manual of LRP-422CST Figure 4-3-6 RMON Counters Page Screenshot Object Description Drop Events The total number of events in which packets were dropped due to lack of resources. Octets The total number of octets received and transmitted on the interface, including framing characters. Packets The total number of packets received and transmitted on the interface. Broadcast Packets The total number of good frames received that were directed to the broadcast address.
User’s Manual of LRP-422CST (excluding framing bits, but including FCS octets) and were otherwise well formed. Fragments The total number of frames received that were less than 64 octets in length (excluding framing bits, but including FCS octets) and had either an FCS or alignment error. Jabbers The total number of frames received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either an FCS or alignment error.
User’s Manual of LRP-422CST 4.3.4 Bandwidth Utilization The Bandwidth Utilization page displays the percentage of the total available bandwidth being used on the ports. Bandwidth utilization statistics can be viewed using a line graph. The Bandwidth Utilization screen in Figure 4-3-7 appears.
User’s Manual of LRP-422CST 4.3.5 Port Mirroring Configure port Mirroring on this page. This function provides monitoring of network traffic that forwards a copy of each incoming or outgoing packet from one port of a network switch to another port where the packet can be studied. It enables the manager to keep close track of switch performance and alter it if necessary.
User’s Manual of LRP-422CST Figure 4-3-9 Port Mirroring Settings Page Screenshot The page includes the following fields: Object Description Session ID Set the port mirror session ID. Possible ID are: 1 to 4. Monitor Session State Enable or disable the port mirroring function. Destination Port Select the port to mirror destination port. Allow-ingress Frames from ports that have either source (RX) or destination (TX) mirroring enabled are mirrored to this port.
User’s Manual of LRP-422CST Figure 4-3-10 Mirroring Status Page Screenshot The page includes the following fields: Object Description Session ID Display the session ID Destination Port This is the mirroring port entry Ingress State Display the ingress state Source TX Port Display the current TX ports Source RX Port Display the current RX ports 4.3.6 Jumbo Frame This page provides to select the maximum frame size allowed for the switch port.
User’s Manual of LRP-422CST Buttons : Click to apply changes. Figure 4-3-12 Jumbo Frame Information Page Screenshot The page includes the following fields: Object Description Jumbo Display the current maximum frame size Jumbo Frame is available for GE1~GE4 only.
User’s Manual of LRP-422CST 4.3.7 Port Error Disabled Configuration This page provides to set port error disable function. The Port Error Disable Configuration screens in Figure 4-3-13 & Figure 4-3-14 appear. Figure 4-3-13 Error Disabled Recovery Page Screenshot The page includes the following fields: Object Description Recovery Interval The period (in seconds) for which a port will be kept disabled in the event of a port error is detected (and the port action shuts down the port).
User’s Manual of LRP-422CST Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.3.8 Port Error Disabled This page provides disable that transitions a port into error disable and the recovery options. The ports were disabled by some protocols such as BPDU Guard, Loopback and UDLD. The Port Error Disable screen in Figure 4-3-15 appears.
User’s Manual of LRP-422CST For protected port group to be applied, the LRP Managed Switch must first be configured for standard VLAN operation.
User’s Manual of LRP-422CST Figure 4-3-16 Protected Ports Settings Page Screenshot The page includes the following fields: Object Description Port List Select port number from this drop-down list. Port Type Displays protected port types. - Protected: A single stand-alone VLAN that contains one promiscuous port and one or more isolated (or host) ports. This VLAN conveys traffic between the isolated ports and a lone promiscuous port.
User’s Manual of LRP-422CST 4.3.10 EEE What is EEE EEE is a power saving option that reduces the power usage when there is low or no traffic utilization. EEE works by powering down circuits when there is no traffic. When a port gets data to be transmitted all circuits are powered up. The time it takes to power up the circuits is named wakeup time. The default wakeup time is 17 us for 1Gbit links and 30 us for other link speeds.
User’s Manual of LRP-422CST Figure 4-3-19 EEE Enable Status Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port EEE State Display the current EEE state EEE is available for GE1~GE2 only. 4.3.11 SFP Module Information LRP Managed Switch has supported the SFP module with digital diagnostics monitoring (DDM) function, this feature is also known as digital optical monitoring (DOM).
User’s Manual of LRP-422CST The page includes the following fields: Object Description Port Select port number from this drop-down list Figure 4-3-21 Fiber Port Status Page Screenshot The page includes the following fields: Object Description OE-Present Display the current SFP OE-present LOS Display the current SFP LOS 109
User’s Manual of LRP-422CST 4.3.11.2 SFP Module Detail Status The SFP Module Detail Status screen in Figure 4-3-22 appears.
User’s Manual of LRP-422CST 4.4 Link Aggregation Port Aggregation optimizes port usage by linking a group of ports together to form a single Link Aggregated Groups (LAGs). Port Aggregation multiplies the bandwidth between the devices, increases port flexibility, and provides link redundancy. Each LAG is composed of ports of the same speed, set to full-duplex operations. Ports in a LAG can be of different media types (UTP/Fiber, or different fiber types) provided they operate at the same speed.
User’s Manual of LRP-422CST The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between Partner Systems that require high-speed redundant links. Link aggregation lets you group up to eight consecutive ports into a single dedicated connection. This feature can expand bandwidth to a device on the network. LACP operation requires full-duplex mode. For more detailed information, refer to the IEEE 802.3ad standard.
User’s Manual of LRP-422CST Figure 4-4-2 LAG Setting Page Screenshot The page includes the following fields: Object Description Load Balance Select load balance algorithm mode: Algorithm MAC Address: The MAC address can be used to calculate the port for the frame. IP/MAC Address: The IP and MAC address can be used to calculate the port for the frame. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.4.2 LAG Management This page is used to configure the LAG management. The LAG Management screens in Figure 4-4-4 & Figure 4-4-5 appear. Figure 4-4-4 LAG Management Page Screenshot The page includes the following fields: Object Description LAG Select LAG number from this drop-down list Name Indicates each LAG name Type Indicates the trunk type Static: Force aggregated selected ports to be a trunk group.
User’s Manual of LRP-422CST LAG The LAG for the settings contained in the same row Name Display the current name Type Display the current type Link State Display the link state Active Member Display the active member Standby Member Display the standby member Modify Click to modify LAG configuration 4.4.3 LAG Port Setting This page allows setting configuration for each LAG. The LAG Port Setting screens in Figure 4-4-6 & Figure 4-4-7 appear.
User’s Manual of LRP-422CST capability that is advertised to the link partner. When a fixed-speed setting is selected, that is what is used. The current RX column indicates whether pause frames on the port are obeyed. The current TX column indicates whether pause frames on the port are transmitted. The RX and TX settings are determined by the result of the last Auto-Negotiation. Check the configured column to use flow control. This setting is related to the setting for Configured Link Speed.
User’s Manual of LRP-422CST 4.4.4 LACP Setting This page is used to configure the LACP system priority setting. The LACP Setting screens in Figure 4-4-8 & Figure 4-4-9 appear. Figure 4-4-8 LACP Setting Page Screenshot The page includes the following fields: Object Description System Priority A value which is used to identify the active LACP. The LRP Managed Switch with the lowest value has the highest priority and is selected as the active LACP peer of the trunk group.
User’s Manual of LRP-422CST 4.4.5 LACP Port Setting This page is used to configure the LACP port setting. The LACP Port Setting screens in Figure 4-4-10 & Figure 4-4-11 appear. Figure 4-4-10 LACP Port Setting Page Screenshot The page includes the following fields: Object Description Port Select Select port number from this drop-down list to set LACP port setting. Priority The Priority controls the priority of the port.
User’s Manual of LRP-422CST Object Description Port Name The switch port number of the logical port Priority Display the current LACP priority parameter Timeout Display the current timeout parameter 4.4.6 LAG Status This page displays LAG status. The LAG Status screens in Figure 4-4-12 & Figure 4-4-13 appear.
User’s Manual of LRP-422CST Figure 4-4-13 LACP Information Page Screenshot The page includes the following fields: Object Description Trunk Display the current trunk ID Port Display the current port number PartnerSysId The system ID of link partner. This field would be updated when the port receives LACP PDU from link partner PnKey Port key of partner. This field would be updated when the port receives LACP PDU from link partner AtKey Port key of actor.
User’s Manual of LRP-422CST “Expired”. The contents could be true or false. If the contents are false, the web shows “_”; if the contents are true, the web shows “A”, “T”, “G”, “S”, “C”, “D”, “F” and “E” for each content respectively. PnState The partner state field of LACP PDU description. The field from left to right describes: “LACP_Activity”, “LACP_Timeout”, “Aggregation”, “Synchronization”, “Collecting”, “Distributing”, “Defaulted”, and “Expired”. The contents could be true or false.
User’s Manual of LRP-422CST 4.5 VLAN 4.5.1 VLAN Overview A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than the physical layout. VLAN can be used to combine any collection of LAN segments into an autonomous user group that appears as a single LAN. VLAN also logically segment the network into different broadcast domains so that packets are forwarded only between ports within the VLAN.
User’s Manual of LRP-422CST This section has the following items: Management VLAN Configures the management VLAN Create VLAN Creates the VLAN group Interface Settings Configures mode and PVID on the VLAN port Port to VLAN Configures the VLAN membership Port VLAN Membership Displays the VLAN membership Protocol VLAN Group Configures the protocol VLAN group Setting Protocol VLAN Port Configures the protocol VLAN port setting Setting GVRP Setting Configures GVRP global se
User’s Manual of LRP-422CST ■ IEEE 802.1Q Standard IEEE 802.1Q (tagged) VLAN are implemented on the Switch. 802.1Q VLAN require tagging, which enables them to span the entire network (assuming all switches on the network are IEEE 802.1Q-compliant). VLAN allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a VLAN will only be forwarded to the stations (over IEEE 802.
User’s Manual of LRP-422CST The Ether Type and VLAN ID are inserted after the MAC source address, but before the original Ether Type/Length or Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic Redundancy Check (CRC) must be recalculated. Adding an IEEE802.1Q Tag Dest. Addr. Src. Addr. Length/E. type Dest. Addr. Src. Addr. E. type Priority Tag CFI Data Old CRC Length/E.
User’s Manual of LRP-422CST ■ Assigning Ports to VLANs Before enabling VLANs for the switch, you must first assign each port to the VLAN group(s) in which it will participate. By default all ports are assigned to VLAN 1 as untagged ports. Add a port as a tagged port if you want it to carry traffic for one or more VLANs, and any intermediate network devices or the host at the other end of the connection supports VLANs.
User’s Manual of LRP-422CST 4.5.3 Management VLAN Configure Management VLAN on this page. The screens in Figure 4-5-1 & Figure 4-5-2 appear. Figure 4-5-1 Management VLAN Setting Page Screenshot The page includes the following fields: Object Description Management VLAN Provide the managed VLAN ID Buttons : Click to apply changes. Figure 4-5-2 Management VLAN State Page Screenshot The page includes the following fields: Object Description Management VLAN Display the current management VLAN.
User’s Manual of LRP-422CST 4.5.4 Create VLAN Create/delete VLAN on this page. The screens in Figure 4-5-3 & Figure 4-5-4 appear. Figure 4-5-3 VLAN Setting Page Screenshot The page includes the following fields: Object Description VLAN List Indicates the ID of this particular VLAN. VLAN Action This column allows users to add or delete VLAN s. VLAN Name Prefix Indicates the name of this particular VLAN. Buttons : Click to apply changes.
User’s Manual of LRP-422CST VLAN Type Display the current VLAN ID type Modify Click to modify VLAN configuration 4.5.5 Interface Settings This page is used for configuring the LRP Managed Switch port VLAN. The VLAN per Port Configuration Page contains fields for managing ports that are part of a VLAN. The port default VLAN ID (PVID) is configured on the VLAN Port Configuration Page. All untagged packets arriving to the device are tagged by the ports PVID.
User’s Manual of LRP-422CST A service provider’s customers may have specific requirements for their internal VLAN IDs and number of VLANs supported. VLAN ranges required by different customers in the same service-provider network might easily overlap, and traffic passing through the infrastructure might be mixed.
User’s Manual of LRP-422CST Figure 4-5-5 Edit Interface Setting Page Screenshot The page includes the following fields: Object Description Port Select Select port number from this drop-down list to set VLAN port setting. Interface VLAN Mode Set the port in access, trunk, hybrid and tunnel mode. Trunk means the port allows traffic of multiple VLANs. Access indicates the port belongs to one VLAN only. Hybrid means the port allows the traffic of multi-VLANs to pass in tag or untag mode.
User’s Manual of LRP-422CST TPID Configure the type (TPID) of the protocol of switch trunk port. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.5.6 Port to VLAN Use the VLAN Static Table to configure port members for the selected VLAN index. This page allows you to add and delete port members of each VLAN. The screen in Figure 4-5-7 appears. Figure 4-5-7 Port to VLAN Setting Page Screenshot The page includes the following fields: Object Description VLAN ID Select VLAN ID from this drop-down list to assign VLAN membership. Port The switch port number of the logical port.
User’s Manual of LRP-422CST Forbidden: Interface is forbidden from automatically joining the VLAN via GVRP. Excluded: Interface is not a member of the VLAN. Packets associated with this VLAN will not be transmitted by the interface. Tagged: Interface is a member of the VLAN. All packets transmitted by the port will be tagged, that is, carry a tag and therefore carry VLAN or CoS information. Untagged: Interface is a member of the VLAN.
User’s Manual of LRP-422CST 4.5.7 Port VLAN Membership This page provides an overview of membership status for VLAN users. The VLAN Membership Status screen in Figure 4-5-8 appears.
User’s Manual of LRP-422CST 4.5.8 Protocol VLAN Group Setting The network devices required to support multiple protocols cannot be easily grouped into a common VLAN. This may require non-standard devices to pass traffic between different VLANs in order to encompass all the devices participating in a specific protocol. This kind of configuration deprives users of the basic benefits of VLANs, including security and easy accessibility.
User’s Manual of LRP-422CST vary depending on the new frame type you selected. Protocol Value Valid value that can be entered in this text field depends on the option selected from the preceding Frame Type selection menu. (0x0600-0xFFFE) Valid values for frame type ranges from 0x0600-0xfffe Buttons : Click to apply changes.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Port Select port from this drop-down list to assign protocol VLAN port Group Select group ID from this drop-down list to protocol VLAN group VLAN VLAN ID assigned to the Special Protocol VLAN Group Buttons : Click to add protocol VLAN port entry.
User’s Manual of LRP-422CST 4.5.10 GVRP Setting GARP VLAN Registration Protocol (GVRP) defines a way for switches to exchange VLAN information in order to register VLAN members on ports across the network. VLANs are dynamically configured based on join messages issued by host devices and propagated throughout the network. GVRP must be enabled to permit automatic VLAN registration, and to support VLANs which extend beyond the local switch.
User’s Manual of LRP-422CST Object Description GVRP Controls whether GVRP is enabled or disabled on this switch. Join Timeout The interval between transmitting requests/queries to participate in a VLAN group. Range: 20-16375 centiseconds Default: 20 centiseconds Leave Timeout The interval a port waits before leaving a VLAN group. This time should be set to more than twice the join time.
User’s Manual of LRP-422CST The page includes the following fields: Object Description GVRP Status Display the current GVRP status Join Timeout Display the current join timeout parameter Leave Timeout Display the current leave timeout parameter LeaveAll Timeout Display the current leaveall timeout parameter 4.5.11 GVRP Port Setting The GVRP Port Setting/Status screens in Figure 4-5-15 & Figure 4-5-16 appear.
User’s Manual of LRP-422CST Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.5.12 GVRP VLAN The GVRP VLAN Database screen in Figure 4-5-17 appears. Figure 4-5-17 GVRP VLAN Database Status Page Screenshot The page includes the following fields: Object Description VLAN ID Display the current VLAN ID Member Ports Display the current member ports Dynamic Ports Display the current dynamic ports VLAN Type Display the current VLAN type 4.5.
User’s Manual of LRP-422CST Figure 4-5-18 GVRP Port Statistics Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Join Empty (Rx/Tx) Display the current join empty (TX/RX) packets Empty (Rx/Tx) Display the current empty (TX/RX) packets Leave Empty (Rx/Tx) Display the current leave empty (TX/RX) packets Join In (Rx/Tx) Display the current join in (TX/RX) packets Leave In (Rx/Tx) Display the current leave in (TX
User’s Manual of LRP-422CST Figure 4-5-19 GVRP Port Error Statistics Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port.
User’s Manual of LRP-422CST 4.5.14 VLAN setting example: - Separate VLANs - 802.1Q VLAN Trunk 4.5.14.1 Two Separate 802.1Q VLANs The diagram shows how the LRP Managed Switch handles Tagged and Untagged traffic flow for two VLANs. VLAN Group 2 and VLAN Group 3 are separated VLANs. Each VLAN isolates network traffic so only members of the VLAN receive traffic from the same VLAN members. The screen in Figure 4-5-20 appears and Table 4-5-2 describes the port configuration of the LRP Managed Switches.
User’s Manual of LRP-422CST Untagged packet entering VLAN 2 1. While [PC-1] transmits an untagged packet enters Port-1, the LRP Managed Switch will tag it with a VLAN Tag=2. [PC-2] and [PC-3] will receive the packet through Port-2 and Port-3. 2. [PC-4],[PC-5] and [PC-6] receive no packet. 3. While the packet leaves Port-2, it will be stripped away its tag becoming an untagged packet. 4. While the packet leaves Port-3, it will be kept as a tagged packet with VLAN Tag=2.
User’s Manual of LRP-422CST 2. Assign VLAN mode and PVID to each port: Port-1,Port-2 and Port-3 : VLAN Mode = Hybrid, PVID=2 Port-4,Port-5 and Port-6 : VLAN Mode = Hybrid, PVID=3 3. Assign Tagged/Untagged to each port: VLAN ID = 2: Port-1 & 2 = Untagged, Port-3 = Tagged, Port -4~6 = Excluded. VLAN ID = 3: Port-4 & 5 = Untagged, Port -6 = Tagged, Port-1~3 = Excluded.
User’s Manual of LRP-422CST 4.5.14.2 VLAN Trunking between Two 802.1Q Aware Switches In most cases, they are used for “Uplink” to other switches. VLANs are separated at different switches, but they need to access other switches within the same VLAN group. The screen in Figure 4-5-21 appears. Setup steps 1. Create VLAN Group 2 and 3 Add VLAN group 2 and group 3 2.
User’s Manual of LRP-422CST Port-1,Port-2 and Port-3 : VLAN Mode = Hybrid, PVID=2 Port-4,Port-5 and Port-6 : VLAN Mode = Hybrid, PVID=3 Port-7 : VLAN Mode = Hybrid, PVID=1 3. Assign Tagged/Untagged to each port: VLAN ID = 1: Port-1~6 = Untagged, Port -7 = Excluded. VLAN ID = 2: Port-1 & 2 = Untagged, Port-3 & 7 = Tagged, Port -4~6 = Excluded.
User’s Manual of LRP-422CST VLAN ID = 3: Port-4 & 5 = Untagged, Port -6 & 7= Tagged, Port-1~3 = Excluded.
User’s Manual of LRP-422CST 4.6 Spanning Tree Protocol 4.6.1 Theory The Spanning Tree Protocol can be used to detect and disable network loops, and to provide backup links between switches, bridges or routers. This allows the switch to interact with other bridging devices in your network to ensure that only one route exists between any two stations on the network, and provide backup links which automatically take over when a primary link goes down.
User’s Manual of LRP-422CST The port identifier of the transmitting port The switch sends BPDUs to communicate and construct the spanning-tree topology. All switches connected to the LAN on which the packet is transmitted will receive the BPDU. BPDUs are not directly forwarded by the switch, but the receiving switch uses the information in the frame to calculate a BPDU, and, if the topology changes, initiates a BPDU transmission.
User’s Manual of LRP-422CST From disabled to blocking Figure 4-6-1 STP Port State Transitions You can modify each port state by using management software. When you enable STP, every port on every switch in the network goes through the blocking state and then transitions through the states of listening and learning at power up. If properly configured, each port stabilizes to the forwarding or blocking state.
User’s Manual of LRP-422CST Parameter Description Default Value Bridge Identifier (Not user A combination of the User-set priority and the switch’s 32768 + MAC configurable MAC address.
User’s Manual of LRP-422CST Hello Time – The Hello Time can be from 1 to 10 seconds. This is the interval between two transmissions of BPDU packets sent by the Root Bridge to tell all other Switches that it is indeed the Root Bridge. If you set a Hello Time for your Switch, and it is not the Root Bridge, the set Hello Time will be used if and when your Switch becomes the Root Bridge. The Hello Time cannot be longer than the Max. Age. Otherwise, a configuration error will occur. Max.
User’s Manual of LRP-422CST Figure 4-6-2 Before Applying the STA Rules In this example, only the default STP values are used.
User’s Manual of LRP-422CST The switch with the lowest Bridge ID (switch C) was elected the root bridge, and the ports were selected to give a high port cost between switches B and C. The two (optional) Gigabit ports (default port cost = 20,000) on switch A are connected to one (optional) Gigabit port on both switch B and C. The redundant link between switch B and C is deliberately chosen as a 100 Mbps Fast Ethernet link (default port cost = 200,000).
User’s Manual of LRP-422CST Figure 4-6-4 Global Settings Page Screenshot The page includes the following fields: Object Description Enable Enable or disable the STP function. The default value is "Disabled". BPDU Forward Set the BPDU forward method. PathCost Method The path cost method is used to determine the best path between devices. Therefore, lower values should be assigned to ports attached to faster media, and higher values assigned to ports with slower media.
User’s Manual of LRP-422CST Figure 4-6-5 STP Information Page Screenshot The page includes the following fields: Object Description STP Display the current STP state BPDU Forward Display the current BPDU forward mode Cost Method Display the current cost method Force Version Display the current force version Configuration Name Display the current configuration name Configuration Revision Display the current configuration revision 4.6.
User’s Manual of LRP-422CST Object Description Port Select Select port number from this drop-down list. External Cost (0 = Controls the path cost incurred by the port. The Auto setting will set the path cost as appropriate by the physical link speed, using the 802.1D recommended Auto) values. Using the Specific setting, a user-defined value can be entered. The path cost is used when establishing the active topology of the network.
User’s Manual of LRP-422CST Port Type Link Type IEEE 802.1D-1998 IEEE 802.1w-2001 Ethernet Half Duplex 100 2,000,000 Full Duplex 95 1,999,999 Trunk 90 1,000,000 Half Duplex 19 200,000 Full Duplex 18 100,000 Trunk 15 50,000 Full Duplex 4 10,000 Trunk 3 5,000 Fast Ethernet Gigabit Ethernet Table 4-6-2 Recommended STP Path Costs Port Type Link Type IEEE 802.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Port The switch port number of the logical STP port. Admin Enable Display the current STP port mode status External Cost Display the current external cost. Edge Port Display the current edge port status. BPDU Filter Display the current BPDU filter configuration. BPDU Guard Display the current BPDU guard configuration. P2P MAC Display the current P2P MAC status. 4.6.
User’s Manual of LRP-422CST For MSTP operation, this is the priority of the CIST. Otherwise, this is the priority of the STP/RSTP bridge. Max Hops This defines the initial value of remaining Hops for MSTI information generated at the boundary of an MSTI region. It defines how many bridges a root bridge can distribute its BPDU information. Valid values are in the range 6 to 40 hops.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Priority Display the current CIST priority Max Hop Display the current max. hop Forward Delay Display the current forward delay Max. Age Display the current max. age Tx Hold Count Display the current Tx hold count Hello Time Display the current hello time 4.6.5 CIST Port Setting This page allows you to configure per port CIST priority and cost.
User’s Manual of LRP-422CST Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.6.6 MST Instance Configuration This page allows the user to configure MST Instance Configuration. The MST Instance Setting, Information and Status screens in Figure 4-6-12, Figure 4-6-13 & Figure 4-6-14 appear. Figure 4-6-12 MST Instance Setting Page Screenshot The page includes the following fields: Object Description MSTI ID Allow to assign MSTI ID. The range for the MSTI ID is 1-15. VLAN List (1-4096) Allow to assign VLAN list to special MSTI ID.
User’s Manual of LRP-422CST VLAN List Display the current VLAN list VLAN Count Display the current VLAN count Priority Display the current MSTI priority Figure 4-6-14 MST Instance Status Page Screenshot The page includes the following fields: Object Description MSTI ID Display the MSTI ID.
User’s Manual of LRP-422CST 4.6.7 MST Port Setting This page allows the user to inspect the current STP MSTI port configurations, and possibly change them as well. A MSTI port is a virtual port, which is instantiated separately for each active CIST (physical) port for each MSTI instance configured and applicable for the port. The MSTI instance must be selected before displaying actual MSTI port configuration options. This page contains MSTI port settings for physical and aggregated ports.
User’s Manual of LRP-422CST Figure 4-6-16 MST Port Status Page Screenshot The page includes the following fields: Object Description MSTI ID Display the current MSTI ID Port The switch port number of the logical STP port Identifier (Priority / Display the current identifier (priority / port ID) Port ID) Internal Path Cost Display the current internal path cost configuration / operation Conf/Oper Regional Root Bridge Display the current regional root bridge Internal Root Cost Displ
User’s Manual of LRP-422CST 4.6.8 STP Statistics This page displays STP statistics. The STP statistics screen in Figure 4-6-17 appears.
User’s Manual of LRP-422CST 4.7 Multicast This section has the following items: Properties Configures multicast properties IGMP Snooping Configures IGMP snooping settings IGMP Snooping Statistics Displays the IGMP snooping statistics MLD Snooping Configures MLD snooping settings MLD Snooping Statistics Displays the MLD snooping statistics Multicast Throttling Configures multicast throttling setting Setting Multicast Filter Configures multicast filter 4.7.
User’s Manual of LRP-422CST Figure 4-7-2 Properties Information Page Screenshot The page includes the following fields: Object Description Unknown Multicast Action Display the current unknown multicast action status Forward Method For IPv4 Display the current IPv4 multicast forward method Forward Method For IPv6 Display the current IPv6 multicast forward method 173
User’s Manual of LRP-422CST 4.7.2 IGMP Snooping The Internet Group Management Protocol (IGMP) lets host and routers share information about multicast groups memberships. IGMP snooping is a switch feature that monitors the exchange of IGMP messages and copies them to the CPU for feature processing. The overall purpose of IGMP Snooping is to limit the forwarding of multicast frames to only ports that are a member of the multicast group.
User’s Manual of LRP-422CST Figure 4-7-4 Multicast Flooding Figure 4-7-5 IGMP Snooping Multicast Stream Control 175
User’s Manual of LRP-422CST IGMP Versions 1 and 2 Multicast groups allow members to join or leave at any time. IGMP provides the method for members and multicast routers to communicate when joining or leaving a multicast group. IGMP version 1 is defined in RFC 1112. It has a fixed packet size and no optional data.
User’s Manual of LRP-422CST The states a computer will go through to join or to leave a multicast group are shown below: Figure 4-7-6 IGMP State Transitions IGMP Querier – A router, or multicast-enabled switch, can periodically ask their hosts if they want to receive multicast traffic. If there is more than one router/switch on the LAN performing IP multicasting, one of these devices is elected “querier” and assumes the role of querying the LAN for group members.
User’s Manual of LRP-422CST 4.7.2.1 IGMP Setting This page provides IGMP Snooping related configuration. Most of the settings are global, whereas the Router Port configuration is related to the current unit, as reflected by the page header. The IGMP Snooping Setting and Information screens in Figure 4-7-7, Figure 4-7-8 & Figure 4-7-9 appear. Figure 4-7-7 IGMP Snooping Page Screenshot The page includes the following fields: Object Description IGMP Snooping Status Enable or disable the IGMP snooping.
User’s Manual of LRP-422CST The page includes the following fields: Object Description IGMP Snooping Status Display the current IGMP snooping status. IGMP Snooping Version Display the current IGMP snooping version. IGMP Snooping V2 Report Display the current IGMP snooping v2 report suppression. Suppression Figure 4-7-9 IGMP Snooping Information Page Screenshot The page includes the following fields: Object Description Entry No.
User’s Manual of LRP-422CST 4.7.2.2 IGMP Querier Setting This page provides IGMP Querier Setting. The IGMP Querier Setting screens in Figure 4-7-10 & Figure 4-7-11 appear. Figure 4-7-10 IGMP VLAN Setting Page Screenshot The page includes the following fields: Object Description VLAN ID Select VLAN ID from this drop-down list. Querier State Enable or disable the querier state. The default value is "Disabled".
User’s Manual of LRP-422CST 4.7.2.3 IGMP Static Group Multicast filtering can be dynamically configured using IGMP Snooping and IGMP Query messages as described in above sections. For certain applications that require tighter control, you may need to statically configure a multicast service on the LRP Managed Switch. First add all the ports attached to participating hosts to a common VLAN, and then assign the multicast service to that VLAN group. - Static multicast addresses are never aged out.
User’s Manual of LRP-422CST The page includes the following fields: Object Description VLAN ID Display the current VLAN ID Group IP Address Display the current group IP address Member Ports Display the current member ports Modify Click to edit parameter 4.7.2.4 IGMP Group Table This page provides Multicast Database. The IGMP Group Table screen in Figure 4-7-14 appears.
User’s Manual of LRP-422CST 4.7.2.5 IGMP Router Setting Depending on your network connections, IGMP snooping may not always be able to locate the IGMP querier. Therefore, if the IGMP querier is a known multicast router/ switch connected over the network to an interface (port or trunk) on your LRP Managed Switch, you can manually configure the interface (and a specified VLAN) to join all the current multicast groups supported by the attached router.
User’s Manual of LRP-422CST Figure 4-7-16 Router Port Status Page Screenshot The page includes the following fields: Object Description VLAN ID Display the current VLAN ID Static Ports Display the current static ports Forbidden Ports Display the current forbidden ports Modify Click Click to edit parameter to delete the group ID entry 4.7.2.6 IGMP Router Table This page provides Router Table.
User’s Manual of LRP-422CST VLAN ID Display the current VLAN ID Port Display the current dynamic router ports Expiry Time (Sec) Display the current expiry time Figure 4-7-18 Static Router Table Page Screenshot The page includes the following fields: Object Description VLAN ID Display the current VLAN ID Port Mask Display the current port mask Figure 4-7-19 Forbidden Router Table Page Screenshot The page includes the following fields: Object Description VLAN ID Display the curren
User’s Manual of LRP-422CST 4.7.2.7 IGMP Forward All This page provides IGMP Forward All. The Forward All screen in Figure 4-7-20 appears.
User’s Manual of LRP-422CST Buttons : Click to apply changes. 4.7.3 IGMP Snooping Statics This page provides IGMP Snooping Statics. The IGMP Snooping Statics screen in Figure 4-7-20 appears.
User’s Manual of LRP-422CST Valid RX Display current valid RX Invalid RX Display current invalid RX Other RX Display current other RX Leave RX Display current leave RX Report RX Display current report RX General Query RX Display current general query RX Special Group Query Display current special group query RX RX Special Group & Display current special group & source query RX Source Query RX Leave TX Display current leave TX Report TX Display current report TX Gene
User’s Manual of LRP-422CST 4.7.4 MLD Snooping 4.7.4.1 MLD Setting This page provides MLD Snooping related configuration. Most of the settings are global, whereas the Router Port configuration is related to the current unit, as reflected by the page header. The MLD Snooping Setting, Information and Table screens in Figure 4-7-21, Figure 4-7-22 & Figure 4-7-23 appear.
User’s Manual of LRP-422CST Figure 4-7-22 MLD Snooping information Page Screenshot The page includes the following fields: Object Description MLD Snooping Status Display the current MLD snooping status MLD Snooping Version Display the current MLD snooping version MLD Snooping Report Display the current MLD snooping report suppression Suppression Figure 4-7-23 MLD Snooping Table Page Screenshot The page includes the following fields: Object Description Entry No.
User’s Manual of LRP-422CST Query Robustness Display the current query robustness Query Interval (sec.) Display the current query interval Query Max Response Display the current query max response interval Interval (sec.) Last Member Query count Display the current last member query count Last Member Query Display the current last member query interval Interval (sec) Immediate Leave Display the current immediate leave Modify Click to edit parameter 4.7.4.
User’s Manual of LRP-422CST Figure 4-7-25 MLD Static Groups Page Screenshot The page includes the following fields: Object Description VLAN ID Display the current VLAN ID Group IPv6 Address Display the current group IPv6 address Member Ports Display the current member ports Modify Click to edit parameter. 4.7.4.3 MLD Group Table This page provides MLD Group Table. The MLD Group Table screen in Figure 4-7-26 appears.
User’s Manual of LRP-422CST Member Port Display the current member port Type Member types displayed include Static or Dynamic, depending on selected options Life(Sec) Display the current life 4.7.4.4 MLD Router Setting Depending on your network connections, MLD snooping may not always be able to locate the MLD querier.
User’s Manual of LRP-422CST Figure 4-7-28 Router Port Status Page Screenshot The page includes the following fields: Object Description VLAN ID Display the current VLAN ID Static Ports Display the current static ports Forbidden Ports Display the current forbidden ports Modify Click Click to edit parameter to delete the group ID entry 4.7.4.5 MLD Router Table This page provides Router Table.
User’s Manual of LRP-422CST Object Description VLAN ID Display the current VLAN ID Port Display the current dynamic router ports Expiry Time (Sec) Display the current expiry time Figure 4-7-30 Static Router Table Page Screenshot The page includes the following fields: Object Description VLAN ID Display the current VLAN ID Port Mask Display the current port mask Figure 4-7-31 Forbidden Router Table Page Screenshot The page includes the following fields: Object Description VLAN I
User’s Manual of LRP-422CST 4.7.4.6 MLD Forward All This page provides MLD Forward All. The Forward All screen in Figure 4-7-32 appears.
User’s Manual of LRP-422CST Buttons : Click to apply changes. 4.7.5 MLD Snooping Statics This page provides MLD Snooping Statics. The MLD Snooping Statics screen in Figure 4-7-33 appears.
User’s Manual of LRP-422CST Valid RX Display the current valid RX Invalid RX Display the current invalid RX Other RX Display the current other RX Leave RX Display the current leave RX Report RX Display the current report RX General Query RX Display the current general query RX Special Group Query Display the current special group query RX RX Special Group & Display the current special group & source query RX Source Query RX Leave TX Display the current leave TX Report T
User’s Manual of LRP-422CST 4.7.6 Multicast Throttling Setting Multicast throttling sets a maximum number of multicast groups that a port can join at the same time. When the maximum number of groups is reached on a port, the switch can take one of two actions; either “deny” or “replace”. If the action is set to deny, any new multicast join reports will be dropped. If the action is set to replace, the switch randomly removes an existing group and replaces it with the new multicast group.
User’s Manual of LRP-422CST Figure 4-7-35 IGMP Port Max Groups Information Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Max Groups Display the current Max groups Action Display the current action 4.7.7 Multicast Filter In certain switch applications, the administrator may want to control the multicast services that are available to end users. For example, an IP/TV service is based on a specific subscription plan.
User’s Manual of LRP-422CST multicast group is permitted, the multicast join report is forwarded as normal. If a requested multicast group is denied, the multicast join report is dropped. When you have created a Multicast profile number, you can then configure the multicast groups to filter and set the access mode. Command Usage Each profile has only one access mode; either permit or deny.
User’s Manual of LRP-422CST Action Sets the access mode of the profile; either permit or deny. - Permit Multicast join reports are processed when a multicast group falls within the controlled range. - Deny When the access mode is set to, multicast join reports are only processed when the multicast group is not in the controlled range. Buttons : Click to add multicast profile entry.
User’s Manual of LRP-422CST 4.7.7.2 IGMP Filter Setting The Filter Setting and Status screens in Figure 4-7-38 & Figure 4-7-39 appear. Figure 4-7-38 Filter Setting Page Screenshot The page includes the following fields: Object Description Port Select Select port number from this drop-down list Filter Profile ID Select filter profile ID from this drop-down list Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.7.7.3 MLD Filter Setting The Filter Setting and Status screens in Figure 4-7-40 & Figure 4-7-41 appear. Figure 4-7-40 Filter Setting Page Screenshot The page includes the following fields: Object Description Port Select Select port number from this drop-down list Filter Profile ID Select filter profile ID from this drop-down list Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.8 Quality of Service 4.8.1 Understand QoS Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traffic. QoS enables you to assign various grades of network service to different types of traffic, such as multi-media, video, protocol-specific, time critical, and file-backup traffic. QoS reduces bandwidth limitations, delay, loss, and jitter.
User’s Manual of LRP-422CST 4.8.2 General 4.8.2.1 QoS Properties The QoS Global Setting and Information screen in Figure 4-8-1 & Figure 4-8-2 appear. Figure 4-8-1 QoS Global Setting Page Screenshot The page includes the following fields: Object Description QoS Mode Enable or disable QoS mode Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.8.2.2 QoS Port Settings The QoS Port Settings and Status screens in Figure 4-8-2 & Figure 4-8-3 appear.
User’s Manual of LRP-422CST Figure 4-8-3 QoS Port Status Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port CoS Value Display the current CoS value Remark CoS Display the current remark CoS Remark DSCP Display the current remark DSCP Remark IP Precedence Display the current remark IP precedence 208
User’s Manual of LRP-422CST 4.8.2.3 Queue Settings The Queue Table and Information screens in Figure 4-8-4 & Figure 4-8-5 appear. Figure 4-8-4 Queue Table Page Screenshot The page includes the following fields: Object Description Queue Display the current queue ID Strict Priority Controls whether the scheduler mode is "Strict Priority" on this switch port WRR Controls whether the scheduler mode is "Weighted" on this switch port Weight Controls the weight for this queue.
User’s Manual of LRP-422CST Figure 4-8-5 Queue Information Page Screenshot The page includes the following fields: Object Description Information Name Display the current queue method information Information Value Display the current queue value information 4.8.2.4 CoS Mapping The CoS to Queue and Queue to CoS Mapping screens in Figure 4-8-6 & Figure 4-8-7 appear.
User’s Manual of LRP-422CST Figure 4-8-7 CoS Mapping Page Screenshot The page includes the following fields: Object Description CoS Display the current CoS value Mapping to Queue Display the current mapping to queue Queue Display the current queue value Mapping to CoS Display the current mapping to CoS 211
User’s Manual of LRP-422CST 4.8.2.5 DSCP Mapping The DSCP to Queue and Queue to DSCP Mapping screens in Figure 4-8-8 & Figure 4-8-9 appear. Figure 4-8-8 DSCP to Queue and Queue to DSCP Mapping Page Screenshot The page includes the following fields: Object Description Queue Select Queue value from this drop-down list DSCP Select DSCP value from this drop-down list Buttons : Click to apply changes.
User’s Manual of LRP-422CST Figure 4-8-9 DSCP Mapping Page Screenshot The page includes the following fields: Object Description DSCP Display the current CoS value Mapping to Queue Display the current mapping to queue Queue Display the current queue value Mapping to DSCP Display the current mapping to DSCP 213
User’s Manual of LRP-422CST 4.8.2.6 IP Precedence Mapping The IP Precedence to Queue and Queue to IP Precedence Mapping screens in Figure 4-8-10 & Figure 4-8-11 appear. Figure 4-8-10 IP Precedence to Queue and Queue to IP Precedence Mapping Page Screenshot The page includes the following fields: Object Description Queue Select Queue value from this drop-down list IP Precedence Select IP Precedence value from this drop-down list Buttons : Click to apply changes.
User’s Manual of LRP-422CST Figure 4-8-11 IP Precedence Mapping Page Screenshot The page includes the following fields: Object Description IP Precedence Display the current CoS value Mapping to Queue Display the current mapping to queue Queue Display the current queue value Mapping to IP Display the current mapping to IP Precedence Precedence 215
User’s Manual of LRP-422CST 4.8.3 QoS Basic Mode 4.8.3.1 Global Settings The Basic Mode Global Settings and QoS Information screens in Figure 4-8-12 & Figure 4-8-13 appear. Figure 4-8-12 Basic Mode Global Settings Page Screenshot The page includes the following fields: Object Description Trust Mode Set the QoS mode Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.8.3.2 Port Settings The QoS Port Setting and Status screens in Figure 4-8-14 & Figure 4-8-15 appear. Figure 4-8-14 Basic Mode Global Settings Page Screenshot The page includes the following fields: Object Description Port Select port number from this drop-down list Trust Mode Enable or disable the trust mode Buttons : Click to apply changes.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Port The switch port number of the logical port Trust Mode Display the current trust type 4.8.4 Rate Limit Configure the switch port rate limit for the switch port on this page. 4.8.4.1 Ingress Bandwidth Control This page provides to select the ingress bandwidth preamble. The Ingress Bandwidth Control Setting and Status screens in Figure 4-8-16 & Figure 4-8-17 appear.
User’s Manual of LRP-422CST Figure 4-8-17 Ingress Bandwidth Control Status Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Ingress Rate Limit (Kbps) Display the current ingress rate limit 4.8.4.2 Egress Bandwidth Control This page provides to select the egress bandwidth preamble. The Egress Bandwidth Control Setting and Status screens in Figure 4-8-18 & Figure 4-8-19 appear.
User’s Manual of LRP-422CST Object Description Port Select port number from this drop-down list State Enable or disable the port rate policer. The default value is "Disabled". Rate (Kbps) Configure the rate for the port policer. The default value is "unlimited". Valid values are in the range 0 to 1000000. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.8.4.3 Egress Queue The Egress Queue Bandwidth Control Settings and Status screens in Figure 4-8-20 & Figure 4-8-21 appear. Figure 4-8-20 Egress Queue Bandwidth Settings Page Screenshot The page includes the following fields: Object Description Port Select port number from this drop-down list Queue Select queue number from this drop-down list State Enable or disable the port rate policer. The default value is "Disabled".
User’s Manual of LRP-422CST The page includes the following fields: Object Description Queue ID Display the current queue ID Rate Limit (Kbps) Display the current rate limit 4.8.5 Voice VLAN 4.5.8.1 Introduction to Voice VLAN Configure the switch port rate limit for the switch port on this page. Voice VLAN is specially configured for the user voice data traffic.
User’s Manual of LRP-422CST 4.8.5.2 Properties The Voice VLAN feature enables voice traffic to forward on the Voice VLAN, and then the switch can be classified and scheduled to network traffic. It is recommended that there are two VLANs on a port -- one for voice, one for data. Before connecting the IP device to the switch, the IP phone should configure the voice VLAN ID correctly. It should be configured through its own GUI. This page provides to select the ingress bandwidth preamble.
User’s Manual of LRP-422CST Buttons : Click to apply changes. Figure 4-8-23 Properties Page Screenshot The page includes the following fields: Object Description Voice VLAN State Display the current voice VLAN state. Voice VLAN ID Display the current voice VLAN ID. Remark CoS/802.1p Display the current remark CoS/802.1p. 1p Remark Display the current 1p remark. Aging Display the current aging time.
User’s Manual of LRP-422CST 4.8.5.3 Telephony OUI MAC Setting Configure VOICE VLAN OUI table on this Page. The Telephony OUI MAC Setting screens in Figure 4-8-24 & Figure 4-8-25 appear. Figure 4-8-24 Voice VLAN OUI Settings Page Screenshot The page includes the following fields: Object Description OUI Address A telephony OUI address is a globally unique identifier assigned to a vendor by IEEE. It must be 6 characters long and the input format is "xx:xx:xx" (x is a hexadecimal digit).
User’s Manual of LRP-422CST The page includes the following fields: Object Description OUI Address Display the current OUI address Description Display the current description Modify Click Click to edit voice VLAN OUI group parameter to delete voice VLAN OUI group parameter 4.8.5.4 Telephony OUI Port Setting The Voice VLAN feature enables voice traffic forwarding on the Voice VLAN, then the switch can classify and schedule network traffic.
User’s Manual of LRP-422CST Figure 4-8-27 Voice VLAN Port State Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port State Display the current state CoS Mode Display the current CoS mode 227
User’s Manual of LRP-422CST 4.9 Security This section is to control the access of the LRP Managed Switch, including the user access and management control. The Security page contains links to the following main topics: 802.1X DHCP Snooping RADIUS Server Dynamic ARP Inspection TACACS+ Server IP Source Guard AAA Port Security Access DoS Management Access Method Storm Control 4.9.1 802.1X Overview of 802.1X (Port-based) Authentication In the 802.
User’s Manual of LRP-422CST 4.9.1.1 Understanding IEEE 802.1X Port-based Authentication The IEEE 802.1X standard defines a client-server-based access control and authentication protocol that restricts unauthorized clients from connecting to a LAN through publicly accessible ports. The authentication server authenticates each client connected to a switch port before making available any services offered by the switch or the LAN. Until the client is authenticated, 802.
User’s Manual of LRP-422CST Authentication server—performs the actual authentication of the client. The authentication server validates the identity of the client and notifies the switch whether or not the client is authorized to access the LAN and switch services. Because the switch acts as the proxy, the authentication service is transparent to the client.
User’s Manual of LRP-422CST Figure 4-9-2 EAP Message Exchange Ports in Authorized and Unauthorized States The switch port state determines whether or not the client is granted access to the network. The port starts in the unauthorized state. While in this state, the port disallows all ingress and egress traffic except for 802.1X protocol packets. When a client is successfully authenticated, the port transitions to the authorized state, allowing all traffic for the client to flow normally.
User’s Manual of LRP-422CST 4.9.1.2 802.1X Setting This page allows you to configure the IEEE 802.1X authentication system. The IEEE 802.1X standard defines a port-based access control procedure that prevents unauthorized access to a network by requiring users to first submit credentials for authentication. One or more central servers, the backend servers, determine whether the user is allowed access to the network. These backend (RADIUS) servers are configured on the "Security→802.1X Access Control→802.
User’s Manual of LRP-422CST 4.9.1.3 802.1X Port Setting This page allows you to configure the IEEE 802.1X Port Setting. The 802.1X Port Setting screens in Figure 4-9-5 & Figure 4-9-6 appear. Figure 4-9-5 802.1X Port Setting Page Screenshot The page includes the following fields: Object Description Port Select port from this drop-down list Mode If NAS is globally enabled, this selection controls the port's authentication mode.
User’s Manual of LRP-422CST switch port or if a supplicant is no longer attached. Reauthentication Period Determines the period, in seconds, after which a connected client must be reauthenticated. This is only active if the Reauthentication Enabled checkbox is checked. Valid values are in the range 30 to 65535 seconds. Quiet Period Sets time to keep silent on supplicant authentication failure. Supplicant Period Sets the interval for the supplicant to re-transmit EAP request/identify frame.
User’s Manual of LRP-422CST Object Description Port The switch port number of the logical port. Mode (pps) Display the current mode. Status (pps) Display the current status. Periodic Reauthentication Display the current periodic reauthentication. Reauthentication Period Display the current reauthentication period. Quiet Period Display the current quiet period. Supplicant Timeout Display the current supplicant timeout. Max. EAP Requests Display the current Max. EAP requests.
User’s Manual of LRP-422CST Figure 4-9-7 Guest VLAN Setting Page Screenshot The page includes the following fields: Object Description Guest VLAN ID This is the value that a port's Port VLAN ID is set to if a port is moved into the Guest VLAN. It is only changeable if the Guest VLAN option is globally enabled. Valid values are in the range [1~4094]. Guest VLAN Enabled A Guest VLAN is a special VLAN - typically with limited network access - on which 802.
User’s Manual of LRP-422CST : Click to apply changes.
User’s Manual of LRP-422CST 4.9.1.5 Authenticated Host The Authenticated Host Table screen in Figure 4-9-9 appears. Figure 4-9-9 Authenticated Host Table Page Screenshot The page includes the following fields: Object Description User Name Display the current user name Port Display the current port number Session Time Display the current session time Authentication Method Display the current authentication method MAC Address Display the current MAC address 4.9.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Retries Timeout is the number of seconds, in the range 1 to 10, to wait for a reply from a RADIUS server before retransmitting the request. Timeout for Reply Retransmit is the number of times, in the range 1 to 30, a RADIUS request is retransmitted to a server that is not responding. If the server has not responded after the last retransmit it is considered to be dead.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Server Definition Set the server definition Server IP Address of the RADIUS server IP/name Authentication Port The UDP port to use on the RADIUS Authentication Server. If the port is set to 0 (zero), the default port (1812) is used on the RADIUS Authentication Server. Acct Port The UDP port to use on the RADIUS Accounting Server.
User’s Manual of LRP-422CST Figure 4-9-12 Login Authentication List Page Screenshot The page includes the following fields: Object Description IP Address Display the current IP address Auth Port Display the current auth port Acct Port Display the current acct port Key Display the current key Timeout Display the current timeout Retries Display the current retry times Priority Display the current priority Dead Time Display the current dead time Usage Type Display the cur
User’s Manual of LRP-422CST 4.9.3 TACACS+ Server This page is to configure the RADIUS server connection session parameters. The RADIUS Settings screens in Figure 4-9-13, Figure 4-9-14 & Figure 4-9-15 appear. Figure 4-9-13 Guest VLAN Setting Page Screenshot The page includes the following fields: Object Description Key String The secret key with up to 63 characters long is shared between the TACACS+ server and the switch.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Server Definition Set the server definition Server IP Address of the TACACS+ server IP/name Server Port Network (TCP) port of TACACS+ server used for authentication messages. (Range: 1-65535; Default: 49) Server Key The key is shared between the TACACS+ Authentication Server and the switch.
User’s Manual of LRP-422CST 4.9.4 AAA Authentication, authorization, and accounting (AAA) provides a framework for configuring access control on the LRP Managed Switch. The three security functions can be summarized as follows: Authentication — Identifies users that request access to the network. Authorization — Determines if users can access specific services. Accounting — Provides reports, auditing, and billing for services that users have accessed on the network.
User’s Manual of LRP-422CST 4.9.4.1 Login List This page is to login list parameters. The authentication list screens in Figure 4-9-17 & Figure 4-9-18 appear. Figure 4-9-17 New Authentication List Screenshot The page includes the following fields: Object Description List Name Defines a name for the authentication list Method 1-4 Set the login authentication method: Empty / None / Local / TACACS+ / RADIUS / Enable Buttons : Click to add authentication list.
User’s Manual of LRP-422CST 4.9.4.2 Enable List This page is to login list parameters. The authentication list screens in Figure 4-9-19 & Figure 4-9-20 appear. Figure 4-9-19 New Authentication List Screenshot The page includes the following fields: Object Description List Name Defines a name for the authentication list Method 1-3 Set the login authentication method: Empty / None / Enable / TACACS+ / RADIUS Buttons : Click to add authentication list.
User’s Manual of LRP-422CST 4.9.5 Access This section is to control the access of the LRP Managed Switch, including the different access methods – Telnet, SSH, HTTP and HTTPs. 4.9.5.1 Console The Console Settings and Information screens in Figure 4-9-21 & Figure 4-9-22 appear.
User’s Manual of LRP-422CST Figure 4-9-22 Console Information Page Screenshot The page includes the following fields: Object Description Login Authentication List Display the current login authentication list Enable Authentication List Display the current enable authentication list Session Timeout Display the current session timeout Password Retry Count Display the current password retry count Silent Time Display the current silent time 248
User’s Manual of LRP-422CST 4.9.5.2 Telnet The Telnet Settings and Information screens in Figure 4-9-23 & Figure 4-9-24 appear.
User’s Manual of LRP-422CST Figure 4-9-24 Telnet Information Page Screenshot The page includes the following fields: Object Description Telnet Service Display the current Telnet service Login Authentication List Display the current login authentication list Enable Authentication List Display the current enable authentication list Session Timeout Display the current session timeout Password Retry Count Display the current password retry count Silent Time Display the current silent
User’s Manual of LRP-422CST 4.9.5.3 SSH Configure SSH on this page. This page shows the Port Security status. Port Security is a module with no direct configuration. Configuration comes indirectly from other modules -- the user modules. When a user module has enabled port security on a port, the port is set up for software-based learning.
User’s Manual of LRP-422CST Figure 4-9-26 SSH Information Page Screenshot The page includes the following fields: Object Description SSH Service Display the current SSH service Login Authentication List Display the current login authentication list Enable Authentication List Display the current enable authentication list Session Timeout Display the current session timeout Password Retry Count Display the current password retry count Silent Time Display the current silent time Cu
User’s Manual of LRP-422CST 4.9.5.4 HTTP The HTTP Settings and Information screens in Figure 4-9-27 & Figure 4-9-28 appear. Figure 4-9-25 HTTP Settings Page Screenshot7 The page includes the following fields: Object Description HTTP Service Disable or enable HTTP service Login Authentication List Select login authentication list from this drop-down list Session Timeout Set the session timeout value Buttons : Click to apply changes.
User’s Manual of LRP-422CST Object Description HTTP Service Display the current HTTP service Login Authentication List Display the current login authentication list Session Timeout Display the current session timeout 4.9.5.5 HTTPs The HTTPs Settings and Information screens in Figure 4-9-29 & Figure 4-9-30 appear.
User’s Manual of LRP-422CST Figure 4-9-30 HTTPs Information Page Screenshot The page includes the following fields: Object Description HTTPs Service Display the current HTTPs service Login Authentication List Display the current login authentication list Session Timeout Display the current session timeout 4.9.6 Management Access Method 4.9.6.1 Profile Rules The Profile Rule Table Setting and Table screens in Figure 4-9-31 & Figure 4-9-32 appear.
User’s Manual of LRP-422CST Management Method Indicates the host can access the switch from HTTP/HTTPs/telnet/SSH/SNMP/All interface that the host IP address matched the entry. Action An IP address can contain any combination of permit or deny rules. (Default: Permit rules)Sets the access mode of the profile; either permit or deny. Port Select port from this drop-down list IP-Source Indicates the IP address for the access management entry Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.9.6.2 Access Rules The access profile screens in Figure 4-9-33 & Figure 4-9-34 appear. Figure 4-9-33 Access Profile Page Screenshot The page includes the following fields: Object Description Access Profile Select access profile from this drop-down list Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.9.7 DHCP Snooping 4.9.7.1 DHCP Snooping Overview The addresses assigned to DHCP clients on unsecure ports can be carefully controlled using the dynamic bindings registered with DHCP Snooping. DHCP snooping allows a switch to protect a network from rogue DHCP servers or other devices which send port-related information to a DHCP server. This information can be useful in tracking an IP address back to a physical port.
User’s Manual of LRP-422CST If the global DHCP snooping is disabled, all DHCP packets are forwarded. If DHCP snooping is enabled globally, and also enabled on the VLAN where the DHCP packet is received, all DHCP packets are forwarded for a trusted port. If the received packet is a DHCP ACK message, a dynamic DHCP snooping entry is also added to the binding table.
User’s Manual of LRP-422CST The page includes the following fields: Object Description DHCP Snooping Indicates the DHCP snooping mode operation. Possible modes are: Enabled: Enable DHCP snooping mode operation. When DHCP snooping mode operation is enabled, the request DHCP messages will be forwarded to trusted ports and only allowed reply packets from trusted ports. Disabled: Disable DHCP snooping mode operation. Buttons : Click to apply changes.
User’s Manual of LRP-422CST The DHCP Snooping VLAN Setting screens in Figure 4-9-37 & Figure 4-9-38 appear. Figure 4-9-37 DHCP Snooping VLAN Setting Page Screenshot The page includes the following fields: Object Description VLAN List Indicates the ID of this particular VLAN. Status Indicates the DHCP snooping mode operation. Possible modes are: Enabled: Enable DHCP snooping mode operation.
User’s Manual of LRP-422CST 4.9.7.4 Port Setting Configures switch ports as trusted or untrusted. Command Usage A trusted interface is an interface that is configured to receive only messages from within the network. An untrusted interface is an interface that is configured to receive messages from outside the network or firewall. When DHCP snooping is enabled both globally and on a VLAN, DHCP packet filtering will be performed on any untrusted ports within the VLAN.
User’s Manual of LRP-422CST Figure 4-9-40 DHCP Snooping Port Setting Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Type Display the current type Chaddr Check Display the current chaddr check 263
User’s Manual of LRP-422CST 4.9.7.5 Statistics The DHCP Snooping Statistics screen in Figure 4-9-41 appears.
User’s Manual of LRP-422CST 4.9.7.6 Database Agent Overview of the DHCP Snooping Database Agent When DHCP snooping is enabled, the switch uses the DHCP snooping binding database to store information about untrusted interfaces. The database can have up to 8192 bindings. Each database entry (binding) has an IP address, an associated MAC address, the lease time (in hexadecimal format), the interface to which the binding applies, and the VLAN to which the interface belongs.
User’s Manual of LRP-422CST Object Description Database Type Select database type File Name The name of file image Remote Server Fill in your remote server IP address Write Delay Specify the duration for which the transfer should be delayed after the binding database changes. The range is from 15 to 86400 seconds. The default is 300 seconds (5 minutes). Timeout Specify when to stop the database transfer process after the binding database changes. The range is from 0 to 86400.
User’s Manual of LRP-422CST 4.9.7.7 Rate Limit After enabling DHCP snooping, the switch will monitor all the DHCP messages and implement software transmission. The DHCP Rate Limit Setting and Config screens in Figure 4-9-44 & Figure 4-9-45 appear.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Port The switch port number of the logical port Rate Limit (pps) Display the current rate limit 4.9.7.8 Option 82 Global Setting DHCP provides a relay mechanism for sending information about the switch and its DHCP clients to DHCP servers. Known as DHCP Option 82, it allows compatible DHCP servers to use the information when assigning IP addresses, or to set other services or policies for clients.
User’s Manual of LRP-422CST The page includes the following fields: Object Description State Set the option 2 (remote ID option) content of option 82 added by DHCP request packets. Default means the default VLAN MAC format. User-Define means the remote-id content of option 82 specified by users Buttons : Click to apply changes.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Port Select port from this drop-down list Enable Enable or disable option 82 function on port Allow Untrusted Select modes from this drop-down list. The following modes are available: Drop Keep Replace Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.9.7.10 Option 82 Circuit-ID Setting Set creation method for option 82, users can define the parameters of circuit-id suboption by themselves. Option 82 Circuit-ID Setting screens in Figure 4-9-50 & Figure 4-9-51 appear.
User’s Manual of LRP-422CST 4.9.8 Dynamic ARP Inspection Dynamic ARP Inspection (DAI) is a secure feature. Several types of attacks can be launched against a host or devices connected to Layer 2 networks by "poisoning" the ARP caches. This feature is used to block such attacks. Only valid ARP requests and responses can go through DUT. This page provides ARP Inspection related configuration. A Dynamic ARP prevents the untrusted ARP packets based on the DHCP Snooping Database. 4.9.8.
User’s Manual of LRP-422CST 4.9.8.2 VLAN Setting DAI VLAN Setting screens in Figure 4-9-54 & Figure 4-9-55 appear. Figure 4-9-54 DAI VLAN Setting Page Screenshot The page includes the following fields: Object Description VLAN ID Indicates the ID of this particular VLAN Status Enables Dynamic ARP Inspection on the specified VLAN Options: Enable Disable Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.9.8.3 Port Setting Configures switch ports as DAI trusted or untrusted and check mode. DAI Port Setting screens in Figure 4-9-54 & Figure 4-9-55 appear. Figure 4-9-56 DAI Port Setting Page Screenshot The page includes the following fields: Object Description Port Select port from this drop-down list Type Specify ARP Inspection is enabled on which ports.
User’s Manual of LRP-422CST Figure 4-9-57 DAI Port Setting Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Type Display the current port type Src-Mac Chk Display the current Src-Mac Chk status Dst-Mac Chk Display the current Dst-Mac Chk status IP Chk Display the current IP Chk status IP Allow Zero Display the current IP allow zero status 275
User’s Manual of LRP-422CST 4.9.8.4 Statistics Configures switch ports as DAI trusted or untrusted and check mode. DAI Port Setting screen in Figure 4-9-58 appears.
User’s Manual of LRP-422CST SIP Validation Failures Display the current SIP Validation failures DIP Validation Failures Display the current DIP Validation failures IP-MAC Mismatch Display the current IP-MAC mismatch failures Failures Buttons : Click to clear the statistics. : Click to refresh the statistics. 4.9.8.5 Rate Limit The ARP Rate Limit Setting and Config screens in Figure 4-9-59 & Figure 4-9-60 appear.
User’s Manual of LRP-422CST Figure 4-9-60 ARP Rate Limit Setting Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Rate Limit (pps) Display the current rate limit 278
User’s Manual of LRP-422CST 4.9.9 IP Source Guard IP Source Guard is a secure feature used to restrict IP traffic on DHCP snooping untrusted ports by filtering traffic based on the DHCP Snooping Table or manually configured IP Source Bindings. It helps prevent IP spoofing attacks when a host tries to spoof and use the IP address of another host.
User’s Manual of LRP-422CST 4.9.9.1 Port Settings IP Source Guard is a secure feature used to restrict IP traffic on DHCP snooping untrusted ports by filtering traffic based on the DHCP Snooping Table or manually configured IP Source Bindings. It helps prevent IP spoofing attacks when a host tries to spoof and use the IP address of another host. The IP Source Guard Port Setting and Information screens in Figure 4-9-61 & Figure 4-9-62 appear.
User’s Manual of LRP-422CST Figure 4-9-62 IP Source Guard Port Setting Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Status Display the current status Verify Source Display the current verify source Max Binding Entry Display the current max binding entry Current Binding Entry Display the current binding entry 281
User’s Manual of LRP-422CST 4.9.9.2 Binding Table The IP Source Guard Static Binding Entry and Table Status screens in Figure 4-9-63 & Figure 4-9-64 appear.
User’s Manual of LRP-422CST 4.9.10 Port Security This page allows you to configure the Port Security Limit Control system and port settings. Limit Control allows for limiting the number of users on a given port. A user is identified by a MAC address and VLAN ID. If Limit Control is enabled on a port, the limit specifies the maximum number of users on the port. If this number is exceeded, an action is taken. The action can be one of the four as described below.
User’s Manual of LRP-422CST remain shut down. There are three ways to re-open the port: 1) Disable and re-enable Limit Control on the port or the switch, 2) Click the Reopen button. Discard: If Limit + 1 MAC addresses is seen on the port, it will trigger the action that do not learn the new MAC and drop the package. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.9.11 DoS The DoS is short for Denial of Service, which is a simple but effective destructive attack on the internet. The server under DoS attack will drop normal user data packet due to non-stop processing the attacker’s data packet, leading to the denial of the service and worse can lead to leak of sensitive data of the server. Security feature refers to applications such as protocol check which is for protecting the server from attacks such as DoS.
User’s Manual of LRP-422CST The page includes the following fields: Object Description DMAC = SMAC Enable or disable DoS check mode by DMAC = SMAC Land Enable or disable DoS check mode by land UDP Blat Enable or disable DoS check mode by UDP blat TCP Blat Enable or disable DoS check mode by TCP blat POD Enable or disable DoS check mode by POD IPv6 Min Fragment Enable or disable DoS check mode by IPv6 min fragment ICMP Fragments Enable or disable DoS check mode by ICMP fragment
User’s Manual of LRP-422CST Figure 4-9-68 DoS Information Page Screenshot The page includes the following fields: Object Description DMAC = SMAC Display the current DMAC = SMAC status Land Attach Display the current land attach status UDP Blat Display the current UDP blat status TCP Blat Display the current TCP blat status POD Display the current POD status IPv6 Min Fragment Display the current IPv6 min fragment status ICMP Fragments Display the current ICMP fragment status
User’s Manual of LRP-422CST TCP Min Header Length Display the current TCP min header length TCP-SYN (SPORT < 1024) Display the current TCP syn status Null Scan Attack Display the current null scan attack status X-mas Scan Attack Display the current X-mas scan attack status TCP SYN-FIN Attack Display the current TCP syn-fin attack status TCP SYN-RST Attack Display the current TCP syn-rst attack status TCP Fragment (Offset = 1) Display the TCP fragment (offset = 1) status 4.9.11.
User’s Manual of LRP-422CST Figure 4-9-70 Port Security Setting Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port DoS Protection Display the current DoS protection 289
User’s Manual of LRP-422CST 4.9.12 Storm Control Storm control for the switch is configured on this page. There is an unknown unicast storm rate control, unknown multicast storm rate control, and a broadcast storm rate control. These only affect flooded frames, i.e. frames with a (VLAN ID, DMAC) pair not present on the MAC Address table. 4.9.12.1 Global Setting The Storm Control Global Setting and Information screens in Figure 4-9-71 & Figure 4-9-72 appear.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Unit Display the current unit Preamble & IFG Display the current preamble & IFG 4.9.12.2 Port Setting Storm control for the switch is configured on this page.
User’s Manual of LRP-422CST Buttons : Click to apply changes Figure 4-9-74 Storm Control Information Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Port State Display the current port state Broadcast (Kbps/pps) Display the current broadcast storm control rate Unknown Multicast Display the current unknown multicast storm control rate (Kbps/pps) Unknown Unicast Display the current unknown unicast storm control
User’s Manual of LRP-422CST 4.10 ACL ACL is an acronym for Access Control List. It is the list table of ACEs, containing access control entries that specify individual users or groups permitted or denied to specific traffic objects, such as a process or a program. Each accessible traffic object contains an identifier to its ACL. The privileges determine whether there are specific traffic object access rights.
User’s Manual of LRP-422CST Figure 4-10-2 ACL Table Page Screenshot The page includes the following fields: Object Description Delete Click to delete ACL name entry 4.10.2 MAC-based ACE An ACE consists of several parameters. Different parameter options are displayed depending on the frame type that you select. The MAC-based ACE screens in Figure 4-10-3 & Figure 4-10-4 appear.
User’s Manual of LRP-422CST The page includes the following fields: Object Description ACL Name Select ACL name from this drop-down list Sequence Set the ACL sequence Action Indicates the forwarding action of the ACE. Permit: Frames matching the ACE may be forwarded and learned. Deny: Frames matching the ACE are dropped. Shutdown: Port shutdown is disabled for the ACE. DA MAC Specify the destination MAC filter for this ACE. Any: No DA MAC filter is specified.
User’s Manual of LRP-422CST Buttons : Click to add ACE list.
User’s Manual of LRP-422CST 4.10.3 IPv4-based ACL This page shows the ACL status by different ACL users. Each row describes the ACE that is defined. It is a conflict if a specific ACE is not applied to the hardware due to hardware limitations. IPv4-based ACL screens in Figure 4-10-5 & Figure 4-10-6 appear. Figure 4-10-5 IPv4-based ACL Page Screenshot The page includes the following fields: Object Description ACL Name Create a name from IPv4-based ACL list Buttons : Click to add ACL name list.
User’s Manual of LRP-422CST 4.10.4 IPv4-based ACE An ACE consists of several parameters. Different parameter options are displayed depending on the frame type that you select. The IPv4-based ACE screens in Figure 4-10-7 & Figure 4-10-8 appear.
User’s Manual of LRP-422CST The page includes the following fields: Object Description ACL Name Select ACL name from this drop-down list. Sequence Set the ACL sequence. Action Indicates the forwarding action of the ACE. Permit: Frames matching the ACE may be forwarded and learned. Deny: Frames matching the ACE are dropped. Shutdown: Port shutdown is disabled for the ACE. Protocol Specify the protocol filter for this ACE. Any(IP): No protocol filter is specified.
User’s Manual of LRP-422CST Range: If you want to filter a specific source port range filter with this ACE, you can enter a specific source port range value. A field for entering a source port value appears. The allowed range is 0 to 65535. A frame that hits this ACE matches this source port value. Destination Port Specify the destination port for this ACE. Any: No specific destination port is specified (destination port status is "don't-care").
User’s Manual of LRP-422CST Set: TCP frames where the SYN field is set must be able to match this entry. Unset: TCP frames where the SYN field is set must not be able to match this entry. Don’t Care: Any value is allowed ("don't-care"). FIN Specify the TCP "No more data from sender" (FIN) value for this ACE. Set: TCP frames where the FIN field is set must be able to match this entry. Unset: TCP frames where the FIN field is set must not be able to match this entry.
User’s Manual of LRP-422CST Figure 4-10-8 IPv4-based ACE Table Page Screenshot The page includes the following fields: Object Description ACL Name Display the current ACL name Sequence Display the current sequence Action Display the current action Protocol Display the current protocol Source IP Address Display the current source IP address Source IP Address Display the current source IP address wildcard mask Wildcard Mask Destination IP Address Display the current destination
User’s Manual of LRP-422CST 4.10.5 IPv6-based ACL This page shows the ACL status by different ACL users. Each row describes the ACE that is defined. It is a conflict if a specific ACE is not applied to the hardware due to hardware limitations. IPv6-based ACL screens in Figure 4-10-9 & Figure 4-10-10 appear. Figure 4-10-9 IPv6-based ACL Page Screenshot The page includes the following fields: Object Description ACL Name Create a name from IPv6-based ACL list Buttons : Click to add ACL name list.
User’s Manual of LRP-422CST 4.10.6 IPv6-based ACE An ACE consists of several parameters. Different parameter options are displayed depending on the frame type that you select. The IPv6-based ACE screens in Figure 4-10-11 & Figure 4-10-12 appear.
User’s Manual of LRP-422CST The page includes the following fields: Object Description ACL Name Select ACL name from this drop-down list Sequence Set the ACL sequence Action Indicates the forwarding action of the ACE Permit: Frames matching the ACE may be forwarded and learned. Deny: Frames matching the ACE are dropped. Shutdown: Port shutdown is disabled for the ACE. Protocol Specify the protocol filter for this ACE Any(IP): No protocol filter is specified.
User’s Manual of LRP-422CST matches this source port value. Range: If you want to filter a specific source port range filter with this ACE, you can enter a specific source port range value. A field for entering a source port value appears. The allowed range is 0 to 65535. A frame that hits this ACE matches this source port value. Destination Port Specify the destination port for this ACE. Any: No specific destination port is specified (destination port status is "don't-care").
User’s Manual of LRP-422CST Don’t Care: Any value is allowed ("don't-care"). SYN Specify the TCP "Synchronize sequence numbers" (SYN) value for this ACE. Set: TCP frames where the SYN field is set must be able to match this entry. Unset: TCP frames where the SYN field is set must not be able to match this entry. Don’t Care: Any value is allowed ("don't-care"). FIN Specify the TCP "No more data from sender" (FIN) value for this ACE.
User’s Manual of LRP-422CST Buttons : Click to add ACE list Figure 4-10-12 IPv6-based ACE Table Page Screenshot The page includes the following fields: Object Description ACL Name Display the current ACL name Sequence Display the current sequence Action Display the current action Protocol Display the current protocol Source IP Address Display the current source IP address Source IP Address Display the current source IP address wildcard mask Wildcard Mask Destination IP Address
User’s Manual of LRP-422CST 4.10.7 ACL Binding This page allows you to bind the Policy content to the appropriate ACLs. The ACL Policy screens in Figure 4-10-13 & Figure 4-10-14 appear. Figure 4-10-13 ACL Binding Page Screenshot The page includes the following fields: Object Description Binding Port Select port from this drop-down list ACL Select Select ACL list from this drop-down list Buttons : Click to apply changes.
User’s Manual of LRP-422CST Figure 4-10-14 ACL Binding Table Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port MAC ACL Display the current MAC ACL IPv4 ACL Display the current IPv4 ACL IPv6 ACL Display the current IPv6 ACL Modify Click Click to edit ACL binding table parameter to delete ACL binding entry 310
User’s Manual of LRP-422CST 4.11 MAC Address Table Switching of frames is based upon the DMAC address contained in the frame. The LRP Managed Switch builds up a table that maps MAC addresses to switch ports for knowing which ports the frames should go to (based upon the DMAC address in the frame). This table contains both static and dynamic entries. The static entries are configured by the network administrator if the administrator wants to do a fixed mapping between the DMAC address and switch ports.
User’s Manual of LRP-422CST Figure 4-11-2 Statics MAC Status Page Screenshot The page includes the following fields: Object Description No. This is the number for entries MAC Address The MAC address for the entry VLAN The VLAN ID for the entry Port Display the current port Delete Click to delete static MAC status entry 4.11.2 MAC Filtering By filtering MAC address, the switch can easily filter the pre-configured MAC address and reduce the un-safety.
User’s Manual of LRP-422CST Buttons : Click to add new MAC filtering setting. Figure 4-11-4 Statics MAC Status Page Screenshot The page includes the following fields: Object Description No. This is the number for entries MAC Address The MAC address for the entry VLAN The VLAN ID for the entry Delete Click to delete static MAC status entry. 4.11.3 Dynamic Address Setting By default, dynamic entries are removed from the MAC table after 300 seconds.
User’s Manual of LRP-422CST Buttons : Click to apply changes. Figure 4-11-6 Dynamic Addresses Status Page Screenshot The page includes the following fields: Object Description Aging Time Display the current aging time 4.11.4 Dynamic Learned Dynamic MAC Table The Dynamically Learned MAC Table is shown on this page. The MAC Table is sorted first by VLAN ID and then by MAC address. The Dynamically Learned screens in Figure 4-11-6 & Figure 4-11-7 appear.
User’s Manual of LRP-422CST Buttons : Refreshes the displayed table starting from the "Start from MAC address" and "VLAN" input fields : Flushes all dynamic entries Figure 4-11-7 MAC Address Information Page Screenshot Object Description MAC Address The MAC address of the entry VLAN The VLAN ID of the entry Type Indicates whether the entry is a static or dynamic entry Port The ports that are members of the entry Buttons : Click to add dynamic MAC address to static MAC address.
User’s Manual of LRP-422CST 4.12 LLDP 4.12.1 Link Layer Discovery Protocol Link Layer Discovery Protocol (LLDP) is used to discover basic information about neighboring devices on the local broadcast domain. LLDP is a Layer 2 protocol that uses periodic broadcasts to advertise information about the sending device. Advertised information is represented in Type Length Value (TLV) format according to the IEEE 802.
User’s Manual of LRP-422CST Bridging: transmit LLDP PDU in the same VLAN. Flooding: transmit LLDP PDU for all port. Transmission Interval The switch is periodically transmitting LLDP frames to its neighbors for having the network discovery information up-to-date. The interval between each LLDP frame is determined by the Transmission Interval value. Valid values are restricted to 5 - 32768 seconds.
User’s Manual of LRP-422CST Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.12.3 LLDP Port Setting Use the LLDP Port Setting to specify the message attributes for individual interfaces, including whether messages are transmitted, received, or both transmitted and received. The LLDP Port Configuration and Status screens in Figure 4-12-3 & Figure 4-12-4 appear.
User’s Manual of LRP-422CST 802.3 MAC-PHY: When checked the "802.3 MAC-PHY" is included in LLDP information transmitted. 802.3 Link Aggregation: When checked the "802.3 Link Aggregation" is included in LLDP information transmitted. 802.3 Maximum Frame Size: When checked the "802.3 Maximum Frame Size" is included in LLDP information transmitted. Management Address: When checked the "Management Address" is included in LLDP information transmitted. 802.1 PVID: When checked the "802.
User’s Manual of LRP-422CST The VLAN Name TLV VLAN Selection and LLDP Port VLAN TLV Status screens in Figure 4-12-5 & Figure 4-12-6 appear. Figure 4-12-5 VLAN Name TLV Selection Page Screenshot The page includes the following fields: Object Description Port Select Select port from this drop-down list. VLAN Select Select VLAN from this drop-down list. Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.12.4 LLDP Local Device Use the LLDP Local Device Information screen to display information about the switch, such as its MAC address, chassis ID, management IP address, and port information. The Local Device Summary and Port Status screens in Figure 4-12-7 & Figure 4-12-8 appear.
User’s Manual of LRP-422CST Figure 4-12-8 Port Status Page Screenshot The page includes the following fields: Object Description Interface The switch port number of the logical port.
User’s Manual of LRP-422CST 4.12.5 LLDP Remote Device This page provides a status overview for all LLDP remote devices. The displayed table contains a row for each port on which an LLDP neighbor is detected. The LLDP Remote Device screen in Figure 4-12-9 appears.
User’s Manual of LRP-422CST 4.12.6 MED Network Policy Network Policy Discovery enables the efficient discovery and diagnosis of mismatch issues with the VLAN configuration, along with the associated Layer 2 and Layer 3 attributes, which apply for a set of specific protocol applications on that port. Improper network policy configurations are a very significant issue in VoIP environments that frequently result in voice quality degradation or loss of service.
User’s Manual of LRP-422CST Figure 4-12-10 Voice Auto Mode Configuration and Network Policy Configuration Page Screenshot The page includes the following fields: Object Description LLDP MED Policy for Set the LLDP MED policy for voice application mode Voice Application Network Policy Select network policy number for this drop down list Number Application Type Intended use of the application types: Voice - for use by dedicated IP Telephony handsets and other similar appliances supporting inter
User’s Manual of LRP-422CST policy for the guest voice signaling than for the guest voice media. This application type should not be advertised if all the same network policies apply as those advertised in the Guest Voice application policy. Softphone Voice - for use by softphone applications on typical data centric devices, such as PCs or laptops.
User’s Manual of LRP-422CST Buttons : Click to apply changes.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Port Select Select port from this drop-down list MED Enable Enable or disable MED configuration MED Optional TVLs Configures the information included in the MED TLV field of advertised messages. -Network Policy – This option advertises network policy configuration information, aiding in the discovery and diagnosis of VLAN configuration mismatches on a port.
User’s Manual of LRP-422CST Object Description Interface The switch port number of the logical port LLDP MED Status Display the current LLDP MED status Active Display the current active status Application Display the current application Location Display the current location Inventory Display the current inventory The MED Location Configuration and LLDP MED Port Location Table screens in Figure 4-12-14 & Figure 4-12-15 appear.
User’s Manual of LRP-422CST Figure 4-12-15 LLDP MED Port Location Table Page Screenshot The page includes the following fields: Object Description Port The switch port number of the logical port Coordinate Display the current coordinate Civic Address Display the current civic address ESC ELIN Display the current ESC ELIN 331
User’s Manual of LRP-422CST 4.12.8 LLDP Overloading The LLDP Port Overloading screen in Figure 4-12-16 appears.
User’s Manual of LRP-422CST 4.12.9 LLDP Statistics Use the LLDP Device Statistics screen to general statistics for LLDP-capable devices attached to the switch, and for LLDP protocol messages transmitted or received on all local interfaces. The LLDP Global and Port Statistics screens in Figure 4-12-17 & Figure 4-12-18 appear.
User’s Manual of LRP-422CST Figure 4-12-18 LLDP Port Statistics Page Screenshot The page includes the following fields: Object Description Port The port on which LLDP frames are received or transmitted TX Frame – Total The number of LLDP frames transmitted on the port RX Frame – Total The number of LLDP frames received on the port RX Frame – Discarded If an LLDP frame is received on a port, and the switch's internal table has run full, the LLDP frame is counted and discarded.
User’s Manual of LRP-422CST 4.13 Diagnostics This section provide the Physical layer and IP layer network diagnostics tools for troubleshoot. The diagnostic tools are designed for network manager to help them quickly diagnose problems between point to point and better service customers. Use the Diagnostics menu items to display and configure basic administrative details of the LRP Managed Switch.
User’s Manual of LRP-422CST Figure 4-13-1 Copper Test Page Screenshot The page includes the following fields: Object Description Port Select port from this drop-down list Buttons : Click to run the diagnostics Figure 4-13-2 Test Results Page Screenshot The page includes the following fields: Object Description Port The port where you are requesting Cable Diagnostics Channel A~D Display the current channel status Cable Length A~D Display the current cable length Result Display the
User’s Manual of LRP-422CST 4.13.2 Ping The ping and IPv6 ping allow you to issue ICMP ping packets to troubleshoot IP connectivity issues. The LRP Managed Switch transmits ICMP packets, and the sequence number and roundtrip time are displayed upon reception of a reply. 4.13.3 Ping Test This page allows you to issue ICMP ping packets to troubleshoot IP connectivity issues.
User’s Manual of LRP-422CST Be sure the target IP Address is within the same network subnet of the switch, or you have to set up the correct gateway IP address. 4.13.4 IPv6 Ping Test This page allows you to issue ICMPv6 PING packets to troubleshoot IPv6 connectivity issues. After you press “Apply”, 5 ICMPv6 packets are transmitted, and the sequence number and roundtrip time are displayed upon reception of a reply.
User’s Manual of LRP-422CST 4.14 RMON RMON is the most important expansion of the standard SNMP. RMON is a set of MIB definitions, used to define standard network monitor functions and interfaces, enabling the communication between SNMP management terminals and remote monitors. RMON provides a highly efficient method to monitor actions inside the subnets. MID of RMON consists of 10 groups.
User’s Manual of LRP-422CST Figure 4-14-1: RMON Statistics Detail Page Screenshot The page includes the following fields: Object Description Port Select port from this drop-down list Drop Events The total number of events in which packets were dropped by the probe due to lack of resources Octets The total number of octets of data (including those in bad packets) received on the network 340
User’s Manual of LRP-422CST Packets The total number of packets (including bad packets, broadcast packets, and multicast packets) received Broadcast Packets The total number of good packets received that were directed to the broadcast address Multicast Packets The total number of good packets received that were directed to a multicast address CRC/Alignment Errors The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 oc
User’s Manual of LRP-422CST 4.14.2 RMON Event Configure RMON Event table on this page. The RMON Event screens in Figure 4-14-2 & Figure 4-14-3 appear. Figure 4-14-2: RMON Event Configuration Page Screenshot The page includes the following fields: Object Description Select Index Select index from this drop-down list to create new index or modify index Index Indicates the index of the entry.
User’s Manual of LRP-422CST Buttons : Click to apply changes.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Select Index Select index from this drop-down list Index Indicates the index of the log entry Log Time Indicates Event log time Description Indicates the Event description 4.14.4 RMON Alarm Configure RMON Alarm table on this page. The RMON Alarm screens in Figure 4-14-5 & Figure 4-14-6 appear.
User’s Manual of LRP-422CST Index Indicates the index of the alarm entry Sample Port Select port from this drop-down list Sample Variable Indicates the particular variable to be sampled, the possible variables are: DropEvents: The total number of events in which packets were dropped due to lack of resources. Octets: The number of received and transmitted (good and bad) bytes. Includes FCS, but excludes framing bits.
User’s Manual of LRP-422CST Pkts256to511Octets: The total number of frames (including bad packets) received and transmitted where the number of octets fall within the specified range (excluding framing bits but including FCS octets). Pkts512to1023Octets: The total number of frames (including bad packets) received and transmitted where the number of octets fall within the specified range (excluding framing bits but including FCS octets).
User’s Manual of LRP-422CST Sample Interval Display the current interval Sample Type Display the current sample type Rising Threshold Display the current rising threshold Falling Threshold Display the current falling threshold Rising Event Display the current rising event Falling Event Display the current falling event Owner Display the current owner Action Click to delete RMON alarm entry 4.14.5 RMON History Configure RMON History table on this page.
User’s Manual of LRP-422CST Interval Indicates the interval in seconds for sampling the history statistics data. The range is from 1 to 3600, default value is 1800 seconds. Owner Specify an owner for the history Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.14.6 RMON History Log This page provides a detail of RMON history entries; screen in Figure 4-14-9 appears. Figure 4-14-9: RMON History Status Page Screenshot The page includes the following fields: Object Description History Index Select history index from this drop-down list Buttons : Click to apply changes.
User’s Manual of LRP-422CST 4.15 Power over Ethernet The LRP Managed Switch can easily build a power central-controlled IP phone system, IP camera system and AP group for the enterprise. Without the power-socket limitation, the LRP Managed Switch makes the installation of cameras or WLAN APs easier and more efficient.
User’s Manual of LRP-422CST 4.15.1 Long Reach Power over Ethernet Powered Device Long Reach Power over Ethernet Extenders Enterprise can extend IP Ethernet transmission and inject power over an existing coaxial cable for distance up to 1000m (3280ft) to PoE IP camera, 36 watts (max.) PoE wireless AP and any 802.3af/at complied powered device (PD).
User’s Manual of LRP-422CST In this mode, the port power is not turned on if the PD requests more available power. 4.15.3 Power over Ethernet Configuration This section allows the user to inspect and configure the current PoE configuration setting as screen in Figure 4-16-1 appears. Figure 4-16-1: PoE Configuration Screenshot The page includes the following fields: Object Description System PoE Admin Allows user to enable or disable PoE function.
User’s Manual of LRP-422CST Figure 4-16-2: Current Power Consumption Screenshot This section allows the user to inspect and configure the current PoE port settings as Figure 4-16-3 shows. Figure 4-16-3: Power over Ethernet Configuration Screenshot The page includes the following fields: Object Description PoE Mode There are three modes for PoE mode. Enable: enable PoE function. Disable: disable PoE function. Schedule: enable PoE function in schedule mode.
User’s Manual of LRP-422CST Power Used [W] Power Allocation The Power Used shows how much power the PD currently is using. It can limit the port PoE supply watts. Per port maximum value must be less than 30.8 watts. Total port values must be less than the Power Reservation value. Once power overload is detected, the port will auto shut down and keep in detection mode until PD’s power consumption is lower than the power limit value Buttons : Click to apply changes. 4.15.
User’s Manual of LRP-422CST The screen in Figure 4-16-4 appears. Figure 4-16-4: PoE Schedule Screenshot Please press the Add New Rule button to start setting PoE Schedule function.
User’s Manual of LRP-422CST which schedule profile could be applied to the PoE port. The page includes the following fields: Object Description Profile Set the schedule profile mode. Possible profiles are: Profile1 Profile2 Profile3 Profile4 Week Day Allows user to set week day for defining PoE function by enabling it on the day. Start Hour Allows user to set what hour PoE function does by enabling it. Start Min Allows user to set what minute PoE function does by enabling it.
User’s Manual of LRP-422CST 4.15.5 PoE Alive Check Configuration The PoE Switch can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and without response, the PoE Switch is going to restart PoE port power, and bring the PD back to work. It will greatly enhance the reliability and reduces administrator management burden. This page provides you with how to configure PD Alive Check. The screen in Figure 4-16-5 appears.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Mode Allows user to enable or disable per port PD Alive Check function. By default, all ports are disabled. Ping PD IP Address This column allows user to set PoE device IP address for system making ping to the PoE device. Please note that the PD’s IP address must be set to the same network segment with the PoE Switch.
User’s Manual of LRP-422CST 4.16 Maintenance Use the Maintenance menu items to display and configure basic configurations of the LRP Managed Switch. Under maintenance, the following topics are provided to back up, upgrade, save and restore the configuration. This section has the following items: ■ Factory Default You can reset the configuration of the switch on this page. ■ Reboot Switch You can restart the switch on this page. After restart, the switch will boot normally.
User’s Manual of LRP-422CST 4.16.2 Reboot Switch The Reboot page enables the device to be rebooted from a remote location. Once the Reboot button is pressed, user has to re-login the Web interface for about 60 seconds. The Reboot Switch screen in Figure 4-16-2 appears and click to reboot the system. Figure 4-16-2 Reboot Switch Page Screenshot 4.16.3 Backup Manager This function allows backup of the current image or configuration of the LRP Managed Switch to the local management station.
User’s Manual of LRP-422CST 4.16.4 Upgrade Manager This function allows reloading of the current image or configuration of the LRP Managed Switch to the local management station. The Upgrade Manager screen in Figure 4-16-4 appears. Figure 4-16-4 Upgrade Manager Page Screenshot The page includes the following fields: Object Description Upgrade Method Select upgrade method from this drop-down list. Server IP Fill in your TFTP server IP address.
User’s Manual of LRP-422CST 4.16.5 Dual Image This page provides information about the active and backup firmware images in the device, and allows you to revert to the backup image. The web page displays two tables with information about the active and backup firmware images. The Dual Image Configuration and Information screens in Figure 4-16-5 & Figure 4-16-6 appear.
User’s Manual of LRP-422CST The page includes the following fields: Object Description Flash Partition Display the current flash partition Image Name Display the current image name Image Size Display the current image size Created Time Display the created time 363
User’s Manual of LRP-422CST 5. SWITCH OPERATION 5.1 Address Table The Switch is implemented with an address table. This address table is composed of many entries. Each entry is used to store the address information of some nodes on the network, including MAC address, port no, etc. This information comes from the learning process of Ethernet Switch. 5.
User’s Manual of LRP-422CST 5.5 Auto-Negotiation The STP ports on the Switch have a built-in "Auto-negotiation". This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset). This is done by detecting the modes and speeds when both devices are connected. Both 10BASE-T and 100BASE-TX devices can connect with the port in either half- or full-duplex mode.
User’s Manual of LRP-422CST 6. TROUBLESHOOTING This chapter contains information to help you solve your issue. If the LRP Managed Switch is not functioning properly, make sure the LRP Managed Switch is set up according to instructions in this manual.
User’s Manual of LRP-422CST 4. If that device works, refer to the next step. 5.
User’s Manual of LRP-422CST APPENDIX A A.1 Switch's RJ45 Pin Assignments 1000Mbps, 1000BASE T Contact MDI MDI-X 1 BI_DA+ BI_DB+ 2 BI_DA- BI_DB- 3 BI_DB+ BI_DA+ 4 BI_DC+ BI_DD+ 5 BI_DC- BI_DD- 6 BI_DB- BI_DA- 7 BI_DD+ BI_DC+ 8 BI_DD- BI_DC- Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard. A.
User’s Manual of LRP-422CST The standard RJ45 receptacle/connector There are 8 wires on a standard UTP/STP cable and each wire is color-coded.