Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Injector/Extender LRP-201-KIT User’s Manual
Copyright Copyright © 2018 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of PLANET.
FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications.
Table of Contents 1. Introduction................................................................................................... 5 1.1 Package Contents.................................................................................... 5 1.2. Introduction of Long Reach Power over Ethernet........................................ 6 1.3 Product Features..................................................................................... 6 1.4 Product Specifications..........................................
1. Introduction Thank you for purchasing PLANET Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Kit. The descriptions of the two models are as follows: LRP-201HT Industrial 1-Port 10/100/1000T Ultra PoE PD + 1-Port Coax/UTP Long Reach PoE Injector LRP-201ET Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Extender “Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Kit” mentioned in this manual represents the above two models. 1.
1.2. Introduction of Long Reach Power over Ethernet PLANET LRP-201-KIT PoE over Coaxial/UTP Extender is designed to extend IP Ethernet transmission by injecting power over an existing coaxial, UTP or telephone wire for distance up to 600m (1900ft) to PoE IP camera, PoE wireless AP and any 802.3at/bt complied powered device (PD). It is a perfect solution for sending IP video links and power to remotely-installed PoE IP cameras that are beyond the Ethernet 100-meter distance limit.
zz Power and Ethernet data transmission over coaxial up to 600m zz Power and Ethernet data transmission over UTP up to 400m zz Power and Ethernet data transmission over telephone wire up to 300m zz Complies with IEEE 802.
PoE Budget PoE Mode Ethernet Interface - 100/100/1000Mbps Cabling Cat.
Maximum Distance Coaxial - Max. 200m - Max. 400m - Max. 600m UTP - Max. 100m - Max. 200m - Max. 300m - Max. 400m with PoE++ output (656ft.) with PoE+ output (1312ft.) with PoE output (1,968ft.) with with with with PoE++ output (328ft.) PoE+ output (656ft.) PoE output (984ft.) PoE output (1,312ft.
Enclosure Metal case Installation DIN-rail kit or wall-mount ear Dimensions (W x D x H) 135 x 87.8 x 32mm Weight 520g Power Requirements 510g RJ45 PoE Input: BNC Power over 802.3at/bt 48~54V DC, Coaxial Input: 40~54V 2.5A max. DC, 1.8A max. DC Input: 48~54V DC, RJ45 Power over 2.5A max. Ethernet Input: 40~54V DC, 1.8A max. Standards Conformance Standards Compliance Regulatory Compliance IEEE IEEE IEEE IEEE IEEE 802.3 10BASE-T Ethernet 802.3u 100BASE-TX Fast Ethernet 802.
2. Hardware Description 2.1 LRP-201HT 2.1.1 LRP-201HT Physical Dimensions PoE In 10/100/1000T LNK/ACT SYS Top View LRP-201HT LRP Out PAIR RJ45 BNC P2 FAULT P1 Front View PoE 30W 60W+ LRP-201HT dimensions (W x D x H): 135 x 87.8 x 32mm Bottom View V1+ V1- 1A@24V V2+ V2- PWR1 Fault Input DC 48~54V Reset PWR2 Side View Rear View DIN-Rail Kit Mounting Kit Mounting Kit 163.
2.1.2 LRP-201HT Front Panel and LED Indicators PoE In LRP-201HT 10/100/1000T LNK/ACT SYS PAIR LRP Out RJ45 BNC Injector P2 FAULT P1 PoE 30W 60W+ PoE Input Figure 2-1 shows the front panels of the LRP-201HT Figure 2-1: LRP-201HT Front Panel System LED Color P1 Green P2 Green FAULT Red SYS Green PAIR Green Function Lit: Power 1 is active. Off: Power 1 is inactive. Lit: Power 2 is active. Off: Power 2 is inactive. Lit: Indicates either power 1 or power 2 has no power. Off: No failure.
1000Mbps PoE In Slot LED Color LNK/ ACT Green PoE In Orange Function Lit: Indicates the link through that port is successfully established at 10/100/1000Mbps. Blinks: Indicates that the Switch is actively sending or receiving data over that port. Lit: Indicates the RJ45 port is receiving the PoE power. Button Button Function PAIR Press the PAIR button for 3 seconds to join another LRP extender.
2.2 LRP-201ET 2.2.1 LRP-201ET Physical Dimensions PoE-in-Use LRP-201ET 10/100/1000T LNK/ACT SYS RJ45 PAIR LRP In PWR Front View BNC zz LRP-201ET dimensions (W x D x H): 135 x 87.8 x 32mm Top View Bottom View Reset Side View Rear View DIN-Rail Kit Mounting Kit Mounting Kit 163.
2.2.2 LRP-201ET Front Panel and LED Indicators PoE-in-Use LRP-201ET 10/100/1000T LNK/ACT SYS PAIR RJ45 BNC LRP In PWR Extender Figure 2-4 shows the front panel of the LRP-201ET. Figure 2-4: LRP-201ET Front Panel System LED Color PWR Green SYS Green PAIR Green Function Lit: Indicates the power is on. Lit: Indicates the system is working. Off: Indicates the system is booting. Lit: Indicates the link is working between LRP-201-KIT. Off: Indicates the link is inactive.
3. Installation This section describes the functionalities of the Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Kit’s components and guides you to how to install it on the desktop. Basic knowledge of networking is expected. Please read this chapter completely before continuing. 3.1 Installation Precautions of Remote Power by Coaxial cable As the LRP-201HT is a power over coaxial injector, it only can work with PLANET power over coaxial extender, the LRP-201ET.
3.3 Installation Precautions of Local Power The 6-contact terminal block connector on the upper panel of LRP injector is used for two DC redundant power inputs. Please follow the steps below to insert the power wire. Note Caution 1. When an external power supply and Ultra PoE switch are connected at the same time, the LRP-201HT will give priority to higher voltage of power source. Both data and power are then transmitted to the LRP-201ET. 2.
3.4 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. When the wires are inserted, the LRP Extender will detect the fault status of the power failure and then form an open circuit. The following illustration shows an application example for wiring the fault alarm contacts. Fault Alarm Contacts Fault The Fault Alarm Contacts are energized (CLOSE) for normal operation and will OPEN when failure occurs 1.
3.6 Applications of LRP-201-KIT with coaxial cable Type 1: One LRP-201HT with PoE power input and one LRP-201ET with PoE power output The LRP Injector is powered via IEEE 802.3at/bt PoE. An IEEE 802.3at/bt compliant PoE PD will automatically be powered by the LRP Extender via UTP. LRP-201HT Long Reach PoE Injector P1 LRP-201ET Long Reach PoE Extender P2 FAULT PWR PoE 30W 60W+ PoE Input Injector Extender BNC BNC LRP Out LRP In RJ45 PAIR 802.
1. Before installation, please consider the distance and watts value demand for PD devices. The LRP-201-KIT PoE output capacity and upload / download performance depend on the length of coaxial cable. 2. As there are various resistance values in the category of RG-59/U or RG-6/U cable, the actual data rate will vary on the quality of the copper wire and environmental factors.
Step 3: Connect 48~54V DC power adapter to LRP-201HT power socket, then the PWR LED of LRP-201HT and LRP-201ET should light up immediately. Step 4: Connect Cat. 5e/6 UTP cable to LRP-201ET and IEEE 802.3at/bt complied PoE IP camera or PoE wireless AP.. 1. Before installation, please consider the distance and watts value demand for PD devices. The LRP-201-KIT PoE output capacity and upload / download performance depend on the length of coaxial cable. Note 2.
Installation Instructions Step 1: Remove the “Danger – No Ethernet” labels stuck on the RJ45 LRP port of LRP-201HT and LRP-201ET. Step 2: Connect the LRP Injector (LRP-201HT) and LRP Extender (LRP-201ET) to ends of RJ45 terminated long UTP/telephone wire cable. 1. Please do not connect any Ethernet device to LRP OUT Port of the LRP-201HT; otherwise, it will damage the Ethernet device. Warning 2.
Type 2: LRP-201HT with 48~54V power adapter and LRP-201ET with PoE power output LRP-201HT Long Reach PoE Injector 110-240V AC P1 LRP-201ET Long Reach PoE Extender P2 FAULT PWR PoE 30W 60W+ PoE Input AC-to-DC Adapter 75W/48~54V DC IN Injector Extender BNC BNC LRP Out LRP In RJ45 PAIR RJ45 SYS PAIR SYS Power over UTP Ethernet Switch 10/100/1000T LNK/ACT 802.3bt PoE 10/100/1000T LNK/ACT PoE IP Camera PoE Cat. 5e/6 PoE In LRP-201HT PoE-in-Use LRP-201ET Cat.
1. Before installation, please consider the distance and watts value demand for PD devices. The LRP-201-KIT PoE output capacity and upload / download performance depend on the length of UTP cable. Note 2. As there are various resistance values in the UTP/telephone wire, the actual data rate will vary on the quality of the copper wire and environmental factors. 3. PoE output capacity is based on different DC Power Input / PoE Input. 3.8 Mounting Installation 3.8.
1 2 Step 4: Lightly pull out the lower DIN-rail bracket first and lift it up to remove it from the track. 3.8.2 Wall-mount Plate Mounting To install the Industrial Ethernet Extender on the wall, please follow the instructions described below. Step 1: Remove the DIN-rail bracket from the Industrial Ethernet Extender by loosening the screws. Step 2: Place the wall-mount plate on the rear panel of the Industrial Ethernet Extender.
4. Troubleshooting This chapter contains information to help you solve issues. If the Long Reach PoE over Coaxial/UTP Extender Kit is not functioning properly, make sure the Long Reach PoE over Coaxial/UTP Extender Kit is set up according to instructions in this manual. The power sources that can be accepted by LRP-201HT are: 1. DC 54V power adapter. 2. DC 48V power adapter. 3. IEEE 802.3bt Ultra Power over Ethernet Switch. 4. IEEE 802.3at High Power over Ethernet Switch.
APPENDIX A: Networking Connection A.1 Switch’s RJ45 Pin Assignments 1000Mbps, 1000BASE-T PIN NO MDI MDI-X 1 BI_DA+ BI_DB+ 2 BI_DA- BI_DB- 3 BI_DB+ BI_DA+ 4 BI_DC+ BI_DD+ 5 BI_DC- BI_DD- 6 BI_DB- BI_DA- 7 BI_DD+ BI_DC+ 8 BI_DD- BI_DC- A.2 RJ45 Cable Pin Assignments The standard RJ45 receptacle/connector There are 8 wires on a standard UTP/STP cable and each wire is color-coded.
EC Declaration of Conformity For the following equipment: *Type of Product: Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Extender Industrial 1-Port 10/100/1000T Ultra PoE PD + 1-Port Coax/UTP Long Reach PoE Injector *Model Number: LRP-201ET/LRP-201HT * Produced by: Manufacturer’s Name : Manufacturer’s Address: Planet Technology Corp. 10F., No.96, Minquan Rd., Xindian Dist.