Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port 10/100TX PoE Extender LRP-104CET User’s Manual
Table of Contents 1. Package Contents.................................................................................. 3 2. Application Diagram............................................................................... 4 2.1 Point to Multi-point......................................................................... 4 2.1.1 LRP-101CH to LRP-104CET..................................................... 4 2.1.2 LRP-101UH to LRP-104CET.................................................... 5 2.
1. Package Contents Thank you for purchasing PLANET Industrial 1-Port Long Reach PoE+ 4-Port 10/100TX PoE Extender, LRP-104CET. In the following section, the term “LRP Extender” means the LRP-104CET. Open the box of the LRP Extender and carefully unpack it.
2. Application Diagram PLANET Long Reach PoE solution is designed to extend IP Ethernet transmission and inject power simultaneously into a remote 802.3af/at PoE compliant powered device (PD) beyond the 100 meters distance limit of Ethernet. The solution works in pairs for point to point and point to multipoint connectivity. The LRP-104CET supports two ways as power source to inject 802.3af/at PoE to remote standard PDs (Powered Devices).
Local Power 110-240V AC LRP-104CET Long Reach PoE Extender AC-to-DC Adapter 60W/48~56V DC IN DC P1 Ext. Fault PWR P2 PoE Power Usage 10W 20W 30W 40W 120W/24-48V DC Power Supply 1 2 3 4 ON Port PoE ON OFF 1 ON OFF 2 ON OFF 3 ON OFF 4 Long Reach Power over Ethernet Cat5e/6 LRP IN LNK LRP-101CH Long Reach PoE Injector 802.3af/802.
2.2 Multi-Point to Multi-Point Remote power LRP Power through BNC with DC 56V input or Local Power with External DC input (DC 24V~48V) 2.2.1 LRP-822CS/LRP-1622CS to LRP-104CET Remote LRP Power LRP-822CS Power over Coaxial LRP-104CET 802.3at PoE+ Long Reach PoE Extender P1 P2 PoE IP Camera Ext.
3. Hardware Introduction 3.1 Physical Dimensions LRP-104CET LRP Extender dimensions (W x D x H): 135 x 87.8 x 56mm Top View Rear View DC1 + Fault DC2 + Mounting Kit Input DC 24-48V Mounting Kit Side View DIN-Rail Kit Side View Front View P1 P2 Ext.
3.2 Front Panel The front panel of the LRP Extender consists of 1BNC female/RJ45 connector and 4 10/100BASE-TX RJ45 ports. The LED Indicators are also located on the RJ45 ports of LRP-104CET P1 P2 Ext. Fault PWR PoE Power Usage 10W 20W 30W 40W 1 2 3 4 ON Port 1 2 3 4 PoE ON OFF ON OFF ON OFF ON OFF PWR LRP IN LNK Long Reach PoE Extender 1 2 3 4 LNK ACT PoE In-use LRP-104CET Figure 3-2: LRP-104CET Front Panel 3.
3.4 LED Indicators External Power Supply LED Color P1 Green Lights to indicate power 1 has power. Function P2 Green Lights to indicate power 2 has power. FAULT Red Lights to indicate either power 1 or power 2 has no power. PoE Usage LED Color Function 10W Green Lights to indicate the power usage is ≥ 10W. 20W Green Lights to indicate the power usage is ≥ 20W. 30W Green Lights to indicate the power usage is ≥ 30W. 40W Green Lights to indicate the power usage is ≥ 40W.
3.5 PoE DIP Switch Indication The LRP Extender provides an adjustable switch that can be used to control the operation of the PoE output.
4. Hardware Specifications Model LRP-104CET Hardware Specifications Ethernet Interface Long Reach PoE Interface Copper Ports Four 10/100BASE-TX RJ45 auto-MDI/ MDI-X PoE Injector Ports Four ports with 802.3at/af PoE injector function with Port-1 to Port-4 Functionality Four DIP switches to control PoE output on or off with Port-1 to Port-4 PoE Standards Compliance IEEE 802.
Long Reach PoE Interface 12 Cabling Coaxial cable: 75 ohm RG-6/U cable, less than12Ω/1000 ft RG-59/U cable, less than 30Ω/1000 ft. Cat. 3, 4, 5, 5e UTP cable (100 meters, max.) EIA/TIA-568 100-ohm STP (100 meters, max.) Maximum Distance Max. 200m with PoE+ output (656ft.) Max. 400m with PoE output (1,312ft.) Max. 1000m without PoE output (3,280ft.) Max. 100m with PoE+ output (328ft.) Max. 400m with PoE output (1,312ft.
3 x LED for External power supply: LED Indicator 4 x LED for PoE Usage: Green: DC Power 1 Green: DC Power 2 Red: Power Fault Green: 10W/20W/30W/40W 2 x LED for Long Reach PoE In: Green: PWR 2 x LED for each RJ45 interface (Port-1 and Port-4) Green: 10/100Mbps LNK/ACT Green: LNK Orange: PoE-in-use Installation DIN rail kit and wall mount kit Dimensions (W x D x H) 135 x 87.
Environment Temperature Operating: -20~70 degrees C Storage: -20~70 degrees C Humidity Operating: 5~95% (non-condensing) Storage: 5~95% (non-condensing) Performance 802.
5. Installation Precautions The LRP-104CET supports two ways as power source to inject 802.3af/at PoE to remote standard PDs. zz Remote LRP Power from LRP Injector/switch over coaxial/UTP cable zz Local DC power from power supply through LRP-104CET’s terminal block 5.1 Installation Precautions of Remote Power by Coaxial Cable When installing LRP PoE over coaxial injector, it only can work with PLANET LRP Extender, the LRP-104CET or LRP-101CE.
5.3 Installation Precautions of Local Power Installation of LRP injector or LRP switch. If you need to increase the PoE power budget of the LRP-104CET, you must use an external DC power supply. The 6-contact terminal block connector on the upper panel of LRP Extender is used for two DC redundant power inputs. Please follow the steps below to insert the power wire.
1. The wire gauge for the terminal block should be in the range between 12 and 24 AWG. Note 2. The DC power input range is 24V ~ 48V DC. 5.4 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the LRP Extender will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
6. Installation This section describes the functionalities of the LRP Extender’s components and guides you to how to install it. Basic knowledge of networking is expected. Please read this chapter completely before continuing. Note Before installation, please consider the distance and watts value demand for PD devices. The LRP-104CET output capacity and upload / download performance depends on the length of coaxial cable and UTP cable.
Installation Instructions Step 1. Connect the LRP Injector (LRP-101CH) and LRP (LRP-104CET) to ends of BNC terminated coaxial cable. Extender Stick the “Warning Sticker” on the coaxial cable. Step 2. Connect Cat5/6 UTP cable to LRP-101CH and IEEE 802.3at compliant PoE Switch or PoE Injector. If the PoE switch or PoE injector is powered on already, then the PWR LED of LRP-101CH and LRP-104CET should be lit up immediately. Step 3. Connect Cat5/6 UTP cable to LRP-104CET and IEEE 802.
Installation Instructions Step 1. Connect the LRP Injector (LRP-101CH) and LRP (LRP-104CET) to ends of BNC terminated coaxial cable. Extender Stick the “Warning Sticker” on the coaxial cable. Step 2. Connect Cat5/6 UTP cable to LRP-101CH and non-PoE switch or workstation. Step 3. Connect 48~56V DC power adapter to LRP-101CH power socket, then the PWR LED of LRP-101CH and LRP-104CET should be lit up immediately. Step 4. Connect Cat5/6 UTP cable to LRP-104CET and IEEE 802.
LRP Switch Functions LRP Extender LRP-822CS/LRP-1622CS LRP-104CET Power Input Power cord with AC 100~240V, 50/60Hz, auto-sensing BNC with DC power over coaxial input Power Output BNC with DC power over coaxial output RJ45 with 802.3at/af PoE output Installation Instructions Step 1. Connect the LRP Switch (LRP-822CS/LRP-1622CS) and LRP Extender (LRP-104CET) to ends of BNC terminated coaxial cable. Step 2.
LRP Injector Functions LRP-101UH LRP Extender LRP-104CET Power Input RJ45 with 802.3at/af PoE input UTP with DC power over UTP input Power Output UTP with DC power over UTP output RJ45 with 802.3at/af PoE output Installation Instructions Step 1. Remove the “Danger – No Ethernet” label stuck on the RJ45 LRP port of LRP-101UH. Step 2. Connect the LRP Injector (LRP-101UH) and LRP Extender (LRP-104CET) to ends of RJ45 terminated long UTP/twisted-pair cable. Warning 1.
Type 2 LRP-101UH with 48~56V power adapter and LRP-104CET with PoE power output Remote LRP Power over UTP 110-240V AC LRP-104CET Long Reach PoE Extender P1 P2 Ext. Fault PWR PoE Power Usage 10W 20W 30W 40W 1 2 3 4 ON AC-to-DC Adapter 60W~120W/48~56V DC IN PWR LRP IN Long Reach Power over Ethernet LNK Long Reach PoE Extender Ethernet Switch Port PoE ON OFF 1 ON OFF 2 ON OFF 3 ON OFF 4 Cat5e/6 1 LRP-101UH Long Reach PoE Injector Power over UTP 2 3 802.3af/802.
Note 1. PoE output capacity is based on different DC Power Input / PoE Input. 2. The LRP-101UH has two power input options; only one mode is available at one time. PoE power input cannot be used if power input of DC 52V or 56V is selected. 6.3 Applications of LRP Injector or LRP Switch powered by External DC power supply The LRP-104CET can be powered via External DC 24~48V input. You can refer to Section 5.3 for Installation Precautions of Local Power.
Functions LRP Extender LRP-101CH LRP-104CET RJ45 with 802.3at/af PoE input External DC 24~48V Power adapter with 48~56V DC in power input Power Input Power Output Warning LRP Injector BNC with DC power over coaxial output RJ45 with 802.3at/af PoE output After the power over coaxial injector is enabled, the center pin of the coaxial cable has electricity. Please do not touch the center pin.
After the power over coaxial injector is enabled, the center pin of the coaxial cable has electricity. Please do not touch the center pin. Warning Type 3 LRP-101UH and LRP-104CET with PoE power output Local Power LRP-104CET Long Reach PoE Extender DC P1 P2 Ext. Fault PWR PoE Power Usage 10W 20W 30W 40W 1 2 3 4 ON PoE PWR Long Reach Power over Ethernet LRP IN LNK 1 LRP-101UH 802.3af/802.3at PoE Long Reach PoE Extender PoE Cat5e/6 802.3af / 802.
Appendix A: Networking Connection A.1 Switch’s RJ45 Pin Assignments 10/100Mbps, 10/100BASE-TX RJ45 Connector pin assignment Contact MDI Media Dependent Interface MDI-X Media Dependent Interface-Cross PoE 1 Tx + (transmit) Rx + (receive) Positive (VCC+) 2 Tx - (transmit) Rx - (receive) Positive (VCC+) 3 Rx + (receive) Tx + (transmit) Negative (VCC-) 4, 5 6 7, 8 Not used Rx - (receive) Tx - (transmit) Not used Not used Negative (VCC-) Not used A.
There are 8 wires on a standard UTP/STP cable and each wire is color-coded.