2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
Note
The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
Note
1. The DC power input range is 12V ~ 48V DC.
2. When the DC power input range is 12V, the PoE
budget is 60W; When the DC power input range
is 24V, the PoE budget is 90W; When the DC
power input range is 48V, the PoE budget is
120W.
To avoid damage, please use the Industrial PoE+
Switch under its specification.
3. Installation
This section describes the functionalities of the Industrial
PoE+ Switch’s components and guides how to install it on the
DIN-rail and wall. Basic knowledge of networking is assumed.
Please read this chapter completely before continuing.
Note
The installation procedures of the ISW-504PT and
ISW-514PTF are the same as they are shown
below.
3.1 DIN-rail Mounting Installation
2.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires,
the Industrial PoE+ Switch will detect the fault status of the
power failure and then forms an open circuit. The following
illustration shows an application example for wiring the fault
alarm contacts.
1 2 3 4 5 6
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be
in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A
currents.
3.2 Wall-mount Plate Mounting
3.3 Side Wall-mount Plate Mounting
4. Troubleshooting
This chapter contains information to help you solve issues. If
the Industrial PoE+ Switch is not functioning properly, make
sure the Industrial PoE+ Switch was set up according to
instructions in this manual.
The per port LED is not lit
Solution:
Check the cable connection of the Industrial PoE+ Switch.
Per port LED is lit, but the trac is irregular
Solution:
Check whether the attached device is not set to dedicated full
duplex. Some devices use a physical or software switch to
change duplex modes. Auto-negotiation may not recognize this
type of full-duplex setting.
Why the Industrial POE+ Switch doesn’t connect to
the network
Solution:
Check each port LED on the Industrial PoE+ Switch. Try
another port on the Industrial PoE+ Switch. Make sure the
cable is installed properly and the right type. Turn o the
power. After a while, turn on the power again.
I connected a PoE powered device to the Industrial
POE+ Switch, why it could not be powered on
Solution:
1. Please check the cable type of the connection from Indus-
trial POE+ Switch (port 1 to port 4) to the other end. The
cable should be an 8-wire UTP, Category 5e or above,
EIA568 cable within 100 meters. A cable with only 4-wire,
short loop or over 100 meters will aect the power supply.
2. Please check and assure the PoE powered device is fully
complied with IEEE 802.3at standard.
5. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at the PLANET Web site rst to
check if it could solve your issue. If you need more support
information, please contact PLANET PoE support team.
FAQ:
https://www.planet.com.tw/en/support/faq?method=category&c1=3
support:
support_switch@planet.com.tw