2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
Note
The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires,
the Industrial PoE+ Switch will detect the fault status of the
power failure and then forms an open circuit. The following
illustration shows an application example for wiring the fault
alarm contacts.
3. Installation
This section describes the functionalities of the Industrial PoE+
Switch’s components and guides you to installing it on the
DIN-rail and wall. Basic knowledge of networking is assumed.
Please read this chapter completely before continuing.
Note
The installation procedures of the ISW-504PT and
ISW-514PTF are the same as they are shown
below.
3.1 DIN-rail Mounting Installation
1 2 3 4 5 6
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be
in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A
currents.
2.6 Grounding the Device
Uses MUST complete grounding wired with the device;
otherwise, a sudden lightning could cause fatal damage to the
device. EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
WARRANTY.
3.2 Wall-mount Plate Mounting
3.3 Side Wall-mount Plate Mounting
4. Troubleshooting
This chapter contains information to help you solve issues. If
the Industrial PoE+ Switch is not functioning properly, make
sure the Industrial PoE+ Switch was set up according to
instructions in this manual.
What is the operating temperature of the device?
Solution:
The operating temperature is from -40 to 75 degrees C.
What is the IP code of the device?
Solution:
The device has a rugged IP40 metal housing
Per port LED is lit, but the trac is irregular
Solution:
Check whether the attached device is not set to dedicated full
duplex. Some devices use a physical or software switch to
change duplex modes. Auto-negotiation may not recognize this
type of full-duplex setting.
Why the Industrial PoE+ Switch doesn’t connect to
the network
Solution:
Check each port LED on the Industrial PoE+ Switch. Try
another port on the Industrial PoE+ Switch. Make sure the
cable is installed properly and the right type. Turn o the
power. After a while, turn on the power again.
I connected a PoE powered device to the Industrial
POE+ Switch, why it could not be powered on
Solution:
1. Please check the cable type of the connection from
Industrial POE+ Switch (port 1 to port 4) to the other
end. The cable should be an 8-wire UTP, Category 5e
or above, EIA568 cable within 100 meters. A cable with
only 4-wire, short loop or over 100 meters will aect the
power supply.
2. Please check and assure the PoE powered device is fully
complied with IEEE 802.3at standard.
5. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at the PLANET Web site rst to
check if it could solve your issue. If you need more support
information, please contact PLANET support team.
PLANET online FAQs:
https://www.planet.com.tw/en/support/
faq?method=category&c1=3
Support team mail address:
support@planet.com.tw