User Manual
26
Step 4: Power on the Industrial Fast Ethernet Switch. (Please refer
to the Wiring the Power Inputs section for power input) The
power LED on the Industrial Fast Ethernet Switch will light
up. Please refer to the LED Indicators section for meaning of
LED lights.
Step 5: Prepare the twisted-pair, straight through Category 5 cable
for Ethernet connection.
Step 6: Insert one side of Category 5 cables into the Industrial Fast
Ethernet Switch Ethernet port (RJ-45 port) and another side
of category 5 cables to the network devices’ Ethernet port
(RJ-45 port), ex: Switch, PC or Server. The UTP port (RJ-45)
LED on the Industrial Fast Ethernet Switch will light up when
the cable connected with the network device. Please refer to
the LED Indicators section for LED light meaning.
Note
Be sure the connected network devices support MDI/
MDI-X. If the network devices do not support MDI/MDI-
X, please use the crossover category 5 Cable to connect.
Step 7: Insert ber cable from the ISW-511 / 621 series or ISW-
511T / ISW-621T series to the ber network. TX, RX must
be paired at both ends. The optical port LED on the Industrial
Fast Ethernet Switch will light up when the cable connected
with network device. Please refer to the LED Indicators
section for LED light meaning.
Step 8: When all connections are set and the LEDs are light without
any issue mean that the installation is complete.