User Manual

- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
3.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of
Industrial Ethernet Switch is used for two DC redundant power
inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an
electric shock.
1. Insert positive and negative DC power wires into contacts 1 and
2 for POWER 1, or contacts 5 and 6 for POWER 2.
Max. fault loading: 24V, 1A
V1+ V1- V2+ V2-
PWR1
PWR2Fault
DC Input: 12-48V
, 2A max.
AC Input: 24V
, 1A max.
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
4. Installation
This section describes the functionalities of the Industrial Ethernet
Switch’s components and guides you to installing it on the DIN rail
and wall. Please read this chapter completely before continuing.
Note
This following pictures show how to install the device.
However, the device in the picture is not ISW-1600T
or IFGS-1822TF.
4.1 DIN-rail Mounting Installation
2
1
Note
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. The power input range is 12V ~ 48V DC and
supports 24V AC.
3. Use one power input when using 24V AC.
3.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial Ethernet Switch will detect the fault status of the power
failure and then forms an open circuit. The following illustration
shows an application example for wiring the fault alarm contacts.
1 2 3 4 5 6
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V DC,1A
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting
5. Customer Support
Thank you for purchasing PLANET products. You can browse our
online FAQ resource on PLANET web site rst to check if it could
solve your issue. If you need more support information, please
contact PLANET switch support team.
PLANET online FAQ:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2019.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
FCC Warning
This equipment has been tested and found to comply with the
regulations for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with this user’s guide, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at his own
expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product
may cause radio interference, in which case the user may be
required to take adequate measures.
WEEE Warning
To avoid the potential eects on the environment and
human health as a result of the presence of hazardous
substances in electrical and electronic equipment, end
users of electrical and electronic equipment should
understand the meaning of the crossed-out wheeled bin symbol. Do
not dispose of WEEE as unsorted municipal waste and have to
collect such WEEE separately.