1. Package Contents
Thank you for purchasing PLANET Industrial 4-port Gigabit 802.3bt
PoE++ Injector Hub, IPOE-470/IPOE-470-12V. In the following sections,
the term “Industrial PoE++ Injector Hub” means the IPOE-470 or
IPOE-470-12V.
Open the box of the Industrial PoE++ Injector Hub and carefully unpack
it. The box should contain the following items:
Industrial PoE++ Injector Hub x 1 User’s Manual x 1
DIN-rail Kit x 1 RJ45 Dust Caps x 8 Wall-mount Kit x 1
If any of these are missing or damaged, please contact your dealer
immediately.
DIP Switch
Per PoE port
O: BT/PoH – 802.3bt PoE++/PoH + Legacy 95W
PoE output
ON: Force - 60w PoE output
Dimensions 50 x 87.8 x 135 mm (W x D x H)
Weight 537g 679g
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
LED Indicator
System:
Power 1 (Green)
Power 2 (Green)
Fault (Red)
PoE Usage:
80W/160W/240W (Amber)
802.3bt PoE++ Port:
PoE-in-use x 1 (Amber)
ESD Protection 6KV
Surge Protection 6KV
Network Cable
Twisted-pair cable up to 100 meters (328ft)
10BASE-T: 4-pair UTP Cat. 3, 4, 5, 5e, 6
100BASE-TX: 4-pair UTP Cat. 5, 5e, 6
1000BASE-T: 4-pair UTP Cat. 5e, 6
Power over Ethernet
PoE Standard
IEEE 802.3bt PoE++, 4-pair type 4 PSE
Backward compatible with IEEE 802.3at PoE+ PSE
PoE Power
Supply Type
802.3bt PoE++/PoH/Force End-span + Mid-span
802.3at PoE+ End-span/Mid-span
DIP Switch Mode Function
BT /PoH
This mode makes the PoE++ Injector Hub operate
as 802.3bt PoE++ type 4 PSE and PoH (Power
over HD-BASE-T) PSE with Legacy function.
Force
This mode makes the PoE++ Injector Hub operate
as 4-pair 60-watt force PoE PSE.
Note
1. After adjusting the DIP switch, the PoE++ Injector Hub
will stop and then work again.
2. Before connecting the “Data + Power” output port to
powered device (PD), make sure that it accepts PoE
input via DIP switch setting to prevent damage.
3. The legacy detection is to identify the PD devices that
do not fully follow the IEEE 802.3af/at/bt standard and
their unique electrical signatures to enable the PoE
injector to provide the power to those PD devices.
3.3 Device Top Panel
The upper panels of the Industrial PoE++ Injector Hubs consist of one
terminal block connector within two power inputs.
Max. fault loading: 24V, 1A
V1+
V2+
PWR1
PWR2Fault
DC Input:
48-54V , 5A max.
1 2 3 4 5 6
Max. fault loading: 24V, 1A
V1+
V2+
PWR1
PWR2Fault
DC Input:
12-54V , 6A max.
1 2 3 4 5 6
Figure 3: IPOE-470 Top View Figure 4: POE-470-12V Top View
3. Hardware Introduction
3.1 Device Front Panel
The front panels of the Industrial PoE++ Injector Hubs consist of
Ethernet interfaces and LED indicators.
Front View
P1
P2 Fault
80W
160W
240W
PoE
Usage
1
DATA
2
3
4
IPOE-470
POE++
Force
ON
BT/PoH
OFF
PoE
Mode
DIPON
1
2
3
4
P1
P2 Fault
80W
160W
240W
PoE
Usage
1
DATA
2
3
4
IPOE-470-12V
POE++
Force
ON
BT/PoH
OFF
PoE
Mode
DIPON
1
2
3
4
Figure 1:
IPOE-470 Front View
Figure 2:
IPOE-470-12V Front View
2.ProductSpecications
Model IPOE-470 IPOE-470-12V
Hardware Specications
Copper Ports
4-pair 10/100/1000BASE-T RJ45
Data input port 1 to Port 4
Data + PoE output port 1 to Port 4
Connector
Removable 6-pin terminal block
Pins 1 and 2 for Power 1
Pins 5 and 6 for Power 2
Pins 4 and 4 for fault alarm
Data Rate 10/100/1000Mbps
Power
Requirements
48~54V DC,
redundant power with
reverse polarity protection
12~54V DC,
redundant power with
reverse polarity protection
Power
Consumption
(Ethernet Full
Loading)
System ON without
loading
48V DC: 1.92 watts/
6.6BTU
54V DC: 2.16 watts/
7.4BTU
Full loading
48V DC: 241 watts/
822.3BTU
54V DC: 244 watts/
832.6BTU
Power
Consumption
(Ethernet Full
Loading)
System ON without
loading
12V DC: 2.52 watts/
8.6BTU
24V DC: 3.6 watts/
12.3BTU
48V DC: 3.36 watts/
11.5BTU
54V DC: 3.24 watts/
11.1BTU
Full loading
12V DC: 72 watts/
245.7BTU
24V DC: 131 watts/
447BTU
48V DC: 249 watts/
849.6BTU
54V DC: 251 watts/
856.5BTU
Power Pin
Assignment
Pair 1 End-span: 1/2(-), 3/6(+)
Pair 2 Mid-span: 4/5(+), 7/8(-)
802.3bt/PoH: 1/2(-), 3/6(+), 4/5(+), 7/8(-)
PoE Power
Output
Max. 90 watts to 802.3bt PoE++ PD
Max. 95 watts to PoH PD
Max. 60 watts to force-powered PD
Max. 36 watts to 802.3at PoE+ PD
PoE Power
Budget (max.)
120W@48V DC input
240W@52V-54V DC input
60W@12V-23V DC input
120W@24V-47V DC input
240W@48-54V DC input
Number of
devices that can
be powered
4
Standards Conformance
Regulatory
Compliance
FCC Part 15 Class A, CE
Stability Testing
IEC 60068-2-32 (free fall)
IEC 60068-2-27 (shock)
IEC 60068-2-6 (vibration)
Standards
Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab Gigabit Ethernet
IEEE 802.3at Power over Ethernet Plus
IEEE 802.3bt Power over Ethernet Plus Plus
Environment
Temperature
Operating: -40~75 degrees C
Storage: -40~75 degrees C
Humidity
Operating: 5~90% (non-condensing)
Storage: 5~90% (non-condensing)
System LEDs
LED Color Function
P1 Green Lights to indicate DC power input 1 has power.
P2 Green Lights to indicate DC power input 2 has power.
Fault Red
Lights to indicate either power 1 or power 2 has
no power.
PoE Usage Amber
80W, 160W, 240W
Lights to indicate the system consumes over 80-
/160-/240-watt PoE power budget.
Blinks to indicate the system consumes less than
80-/160-/240-watt PoE power budget.
802.3bt PoE++ TP Interface LEDs
LED Color Function
802.3bt
PoE++
PoE-in-Use
Amber
Lights to indicate that the port is providing PoE
in-line power to remote powered device.
O to indicate that the port is not providing PoE
in-line power to remote powered device.
3.2 DIP Switch Information
To meet the demand of various powered devices consuming stable PoE
power, the PoE++ Injector Hub provides one DIP switch for three PoE
operation mode options as shown in the following table.
Force
ON
BT/PoH
OFF
PoE
Mode
DIPON
1
2
3
4
3.4 Wiring the Power Inputs
The terminal block connector on the top panel of Industrial PoE++
Injector Hub is used for two DC redundant power inputs. Please follow
the steps below to insert the power wire.
Caution
When performing any of the procedures like inserting the
wires or tightening the wire-clamp screws, make sure the
power is OFF to prevent from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1 and 2 for
POWER 1, or contacts 3 and 4 for POWER 2.
Max. fault loading: 24V, 1A
V1+
V2+
PWR1
PWR2Fault
DC Input:
48-54V , 5A max.
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
1 2 3 4 5 6
V1+ V1- V2+ V2-
Power 1 Power 2 Power 2
Figure 5: PWR1 & PWR2 pins of terminal block