Industrial 802.
Table of Contents 1. Package Contents....................................................................... 3 2. Product Specifications................................................................. 4 3. Product Outlook......................................................................... 7 3.1 Product Outlook................................................................... 7 3.2 Industrial PoE++ Injector Upper Panel..................................10 3.3 Wiring the Power Inputs...................
1. Package Contents Thank you for purchasing PLANET IPOE-171 Single-port 802.3bt PoE++ Injector series. In the following section, the term “IPOE-171 Series” means the IPOE-171-60W or IPOE-171-95W. Model LAN Port Speed PoE Standard PoE Budget IPOE-171-60W 10M/100M/ 1G/2.5G/5Gbps IEEE 802.3at/bt 60 watts IPOE-171-95W 10M/100M/ 1G/2.5G/5Gbps IEEE 802.3at/bt 95 watts Please unpack the box of the device carefully, and the box should contain the following items: 802.
2. Product Specifications Product IPOE-171-60W IPOE-171-95W Hardware Specifications Interface Input Port 1 x RJ45 STP Data In Output Port 1 x RJ45 STP PoE (Data + Power) Out Input Power Terminal Block 1 Network Cable* Twisted-pair cable up to 100 meters (328ft) 10BASE-T: 4-pair UTP Cat. 3, 4, 5, 5e, 6, 6A 100BASE-TX: 4-pair UTP Cat. 5, 5e, 6, 6A 1G/2.5G: 4-pair UTP Cat. 5e, 6, 6A 5G: 4-pair UTP Cat.
Installation DIN-rail kit or wall-mount ear Alarm Provides one relay output for power failure Alarm Relay current carry ability: 1A @ DC 24V Enclosure IP30 slim type metal case Power over Ethernet PoE Standard IEEE 802.3bt Type 3 PSE IEEE 802.3bt Type 4 PSE PoE Power Output Budget DC 50~53V / 60-watt PoE via 4-pair DC 45~53V / 30-watt PoE via 2-pair DC via DC via Max. 60W@1m cable Max. 51W@100m cable -DC 24V~48V input: Max. 89.5W@1m cable Max. 75W@100m cable -DC 12V input: Max.
Regulatory Compliance FCC Part 15 Class A, CE Environment Operating Temperature -40 ~ 75 degrees C Storage Temperature -40 ~ 85 degrees C Operating Humidity 5 ~ 90%, relative humidity, non-condensing Storage Humidity 5 ~ 90%, relative humidity, non-condensing 1. As IEEE 802.3bt device provides high power, please use high-quality network cable and RJ45 connector. Caution 6 2. The maximum PoE output power depends on the cable length, the quality of cable, and DC input voltage.
3. Product Outlook 3.1 Product Outlook P1 P2 Alarm P1 P2 Alarm 20W 40W 60W+ 30W 60W 90W+ PoE Power Usage PoE Power Usage 10/100/1G/2.5G/5G 10/100/1G/2.5G/5G Ethernet Ethernet Standard Legacy Standard 10/100/1G/2.5G/5G PoE in-Use Legacy 10/100/1G/2.5G/5G PoE in-Use Ethernet+DC Ethernet+DC 802.3bt PoE++ 802.
PoE-inAmber Use Lights to indicate the device is providing PoE power. Monitor DC input voltage: When user powers on IPOE-171-60W, the injector will detect the DC input voltage and then PoE Usage LED will flash three times. 20W: Flashing three times means the DC input voltage is 48~50.9V. 40W: Flashing three times means the DC input voltage is 51~52.9V. PoE Usage Amber Monitor power usage: 20W: 1. Off to indicate the PoE usage is less than 9W. 2.
30W: 1. Off to indicate the PoE usage is less than 14W. 2. Blinks to indicate that the PoE usage is around 15W to 29W. 3. Lights to indicate the PoE usage is more than 30W. PoE Usage Amber 60W: 1. Blinks to indicate that the PoE usage is around 45W to 59W. 2. Lights to indicate the PoE usage is more than 60W. 90W+: 1. Blinks to indicate that the PoE usage is around 75W to 89W. 2. Lights to indicate the PoE usage is at the maximum.
3.2 Industrial PoE++ Injector Upper Panel The upper panel of the IPOE-171 series has one terminal block connector where there are two DC power inputs. Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 V2+ V1+ PWR1 Alarm PWR2 DC Input: 48-54V , 2A max. Figure 3: IPOE-171-60W upper panel. Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 V2+ V1+ PWR1 Alarm PWR2 DC Input: 12-54V , 6A max. Figure 4: IPOE-171-95W upper panel. 3.
Step 2: Tighten the wire-clamp screws for preventing the wires from loosening. 1 2 Power 1 + - 3 4 Alarm 5 6 Power 2 + - Figure 6: PWR1 & PWR2 Pins of Terminal Block. 1. The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG. Note 2. As the DC input connector of the IPOE-171 series is polarity protected, connecting Positive/Negative DC power wires to the wrong pins will not damage the unit.
3.4 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. After inserting the wires, the IPOE-171 series will detect the fault status of the power failure and then form an open circuit. The following illustration shows an application example for wiring the fault alarm contacts. Figure 7: Fault Pin of Terminal Block. 1. The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG. Note 2.
4. Mounting Installation This section describes how to install the industrial device and make connections to it. Please read the following sections and perform the procedures in the order being presented. Note In the installation steps below, this manual uses PLANET Industrial Switch as an example. The steps for PLANET Industrial Slim-type Switch, Industrial Media/Serial Converter and Industrial PoE devices are similar. 4.1 DIN-rail Mounting Installation 1 2 4.
4.3 Side Wall-mount Plate Mounting * The above pictures are for illustration only. 4.4 Grounding the Device Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device. Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 V2+ V1+ PWR1 Earth Ground 14 Alarm PWR2 DC Input: 12-54V , 6A max.
5. Hardware Installation The following section describes the hardware features of the IPOE-171 series. Before connecting any network device to it, please read this chapter carefully. 5.1 Before Installation Before your installation, it is recommended to check your network environment. If there is any IEEE 802.3bt device that needs to be powered on and works normally, the IPOE-171 series is the solution that supplies power to this Ethernet device conveniently and easily.
4. The IPOE-171-60W/IPOE-171-95W can directly connect with any IEEE 802.3at/bt end-nodes, such as PTZ (pan, tilt & zoom) IP cameras, PTZ speed dome cameras, color touch screens, Voice over IP (VoIP) telephones and multi-channel wireless LAN access points which support IEEE 802.3at/bt In-line Power over Ethernet port.
6. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource at the PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET support team. PLANET online FAQs: https://www.planet.com.tw/en/support/faq Support team mail address: support@planet.com.tw Copyright © PLANET Technology Corp. 2022. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp.
FCC Statement NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.