1. Package Contents
Thank you for purchasing PLANET IPOE-171 Single-port 802.3bt PoE++
Injector series. In the following section, the term “IPOE-171 Series”
means the IPOE-171-60W or IPOE-171-95W.
Model LAN Port Speed PoE Standard PoE Budget
IPOE-171-60W
10M/100M/
1G/2.5G/5Gbps
IEEE 802.3at/bt 60 watts
IPOE-171-95W
10M/100M/
1G/2.5G/5Gbps
IEEE 802.3at/bt 95 watts
Please unpack the box of the device carefully, and the box should
contain the following items:
802.3bt PoE injector x 1
User’s manual x 1
Dust cap x 2
Wall-mount kit x 1
If any item is found missing or damaged, please contact your local
reseller for replacement.
Unit Output Voltage DC 45~53V DC 54V
Power Consumption 75 watts max. 120 watts max.
No. of devices that can
be powered
1
Installation DIN-rail kit or wall-mount ear
Alarm
Provides one relay output for power failure
Alarm Relay current carry ability: 1A @ DC
24V
Enclosure IP30 slim type metal case
Power over Ethernet
PoE Standard
IEEE 802.3bt Type
3 PSE
IEEE 802.3bt Type
4 PSE
PoE Power Output
Budget
DC 50~53V
/
60-watt
PoE via 4-pair
DC 45~53V
/
30-watt
PoE via 2-pair
DC 54V
/
95-watt PoE
via 4-pair
DC 54V
/
30-watt PoE
via 2-pair
PoE Power Output
Max. 60W@1m cable
Max. 51W@100m
cable
-DC 24V~48V input:
Max. 89.5W@1m
cable
Max. 75W@100m
cable
-DC 12V input:
Max. 60W@1m cable
Max. 52W@100m
cable
PoE Power Supply Type End-span + Mid-span
IPOE-171-95W LED Indicators:
LED Color Function
P1 Green Lights to indicate power 1 has power.
P2 Green Lights to indicate power 2 has power.
FAULT Red
Lights to indicate either power 1 or power 2 has no
power.
PoE-in-
Use
Amber Lights to indicate the device is providing PoE power.
PoE
Usage
Amber
30W:
1. OtoindicatethePoEusageislessthan14W.
2. Blinks to indicate that the PoE usage is around
15W to 29W.
3. Lights to indicate the PoE usage is more than
30W.
60W:
1. Blinks to indicate that the PoE usage is around
45W to 59W.
2. Lights to indicate the PoE usage is more than
60W.
90W+:
1. Blinks to indicate that the PoE usage is around
75W to 89W.
2. Lights to indicate the PoE usage is at the
maximum.
PoE Mode of IPOE-171 series:
PoE Mode Description
Standard
(Default)
The standard mode is chosen to provide power to the PD
devices that follow the IEEE 802.3at/bt standard.
Legacy
The legacy mode supports PoH and Ultra PoE. It is chosen
to provide power to the PD devices that do not fully follow
the IEEE 802.3at/bt standard.
3. Product Outlook
3.1 Product Outlook
20W 40W 60W+
PoE Power Usage
PoE
in-Use
Standard Legacy
10/100/1G/2.5G/5G
Ethernet
10/100/1G/2.5G/5G
Ethernet+DC
P1 P2 Fault
IPOE-171-60W
802.3bt PoE
++
30W 60W 90W+
PoE Power Usage
PoE
in-Use
Standard Legacy
10/100/1G/2.5G/5G
Ethernet
10/100/1G/2.5G/5G
Ethernet+DC
P1 P2 Fault
IPOE-171-95W
802.3bt PoE
++
Figure 1: IPOE-171-60W outlook Figure 2: IPOE-171-95W outlook
2.ProductSpecications
Product IPOE-171-60W IPOE-171-95W
HardwareSpecications
Interface
Input Port
1 x RJ45 STP
Data In
Output Port
1 x RJ45 STP
PoE (Data + Power) Out
Input Power
Terminal
Block
1
Network Cable*
Twisted-pair cable up to 100 meters (328ft)
10BASE-T: 4-pair UTP Cat. 3, 4, 5, 5e, 6, 6A
100BASE-TX: 4-pair UTP Cat. 5, 5e, 6, 6A
1G/2.5G: 4-pair UTP Cat. 5e, 6, 6A
5G: 4-pair UTP Cat. 6, 6A
LED Indicators
System: Power 1 (Green),
Power 2 (Green), Fault (Red)
PoE Port: PoE-in-Use x 1 (Amber)
PoE Usage: PoE Usage x 3 (Amber)
Data Rate 10M/100M/1G/2.5G/5Gbps
Dimensions
(W x D x H)
135 x 87.8 x 32 mm
ESD Protection 6KV DC
Enclosure Metal case
Weight 430g 470g
Power Requirements DC 48~56V, 2A max. DC 12~48V, 5A max.
Power Pin Assignment
Pair 1 End-span: 1/2 (-), 3/6 (+)
Pair 2 Mid-span: 4/5 (+), 7/8 (-)
PoE Mode
Standard mode
Legacy and Force mode
Standards Conformance
Standards Compliance
IEEE 802.3 10BASE-T Ethernet
IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3ab 1000BASE-T Gigabit Ethernet
IEEE 802.3bz 2.5G/5GBASE-T
IEEE 802.3bt 4-pair Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
Regulatory Compliance FCC Part 15 Class A, CE
Environment
Operating Temperature -40 ~ 75 degrees C
Storage Temperature -40 ~ 85 degrees C
Operating Humidity 5 ~ 90%, relative humidity, non-condensing
Storage Humidity 5 ~ 90%, relative humidity, non-condensing
Caution
1. As IEEE 802.3bt device provides high power, please use
high-quality network cable and RJ45 connector.
2. The maximum PoE output power depends on the cable
length, the quality of cable, and DC input voltage.
IPOE-171-60W LED Indicators:
LED Color Function
P1 Green Lights to indicate power 1 has power.
P2 Green Lights to indicate power 2 has power.
FAULT Red
Lights to indicate either power 1 or power 2 has no
power.
PoE-in-
Use
Amber Lights to indicate the device is providing PoE power.
PoE
Usage
Amber
Monitor DC input voltage:
When user powers on POE-171-60W, the injector will
detect the DC input voltage and then PoE Usage LED
willashthreetimes.
20W: Flashing three times means the DC input
voltage is 48~50.9V.
40W: Flashing three times means the DC input
voltage is 51~52.9V.
60W+: Flashing three times means the DC input
voltage is 53~56V.
Monitor power usage:
20W:
1. OtoindicatethePoEusageislessthan9W.
2. Blinks to indicate that the PoE usage is around
10W to 19W.
3. Lights to indicate the PoE usage is more than
20W.
40W:
1. Blinks to indicate that the PoE usage is around
30W to 39W.
2. Lights to indicate the PoE usage is more than 40W
60W+:
1. Blinks to indicate that the PoE usage is around
50W to 59W.
2. Lights to indicate the PoE usage is at the
maximum.
Force
If the output power of injector is less than 1 watt when in
the Legacy mode, after 20 seconds, the Force mode will be
enabled. When the Force mode is enabled, it will provide
PD with a maximum of 60 watts. If the output power of
injector is less than 1 watt when in the Force mode, after 2
seconds, the Legacy mode will be enabled.
Note
After changing the PoE mode, please power off and then
on the PoE injector to make the change effective.
3.2 Industrial PoE++ Injector Upper Panel
The upper panel of the IPOE-171 series has one terminal block
connector where there are two DC power inputs.
DC Input:
48-56V , 2A max.
Max. fault loading: 24V, 1A
V1+
V2+
PWR1
PWR2Fault
1 2 3 4 5 6
Figure 3: IPOE-171-60W upper panel.
Max. fault loading: 24V, 1A
V1+
V2+
PWR1
PWR2Fault
DC Input:
12-48V , 5A max.
1 2 3 4 5 6
Figure 4: IPOE-171-95W upper panel.