4.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires,
the Industrial PoE+ Injector will detect the fault status of the
power failure and then forms an open circuit. The following
illustration shows an application example for wiring the fault
alarm contacts.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Figure 4-6: Fault Alarm Contact
Note
The wire gauge for the terminal block should be in
the range of 12 to 24 AWG.
Alarm relay circuit accepts up to a maximum of
30V, 3A currents.
Step 2: The lower DIN-rail bracket is then placed into the
track.
Figure 5-2: Complete DIN-rail mounting
5.2 Removal of Device
Step 1: Please refer to following procedure to remove the
device from the track.
1
2
Figure 5-3: Removal of Device from Track
5. Mounting Installation
This section describes how to install the Industrial Equipment
and make connections to it. Please read the following topics
and perform the procedures in the order being presented.
Note
This following picture tells the user how to install
the device, and the device is not IPOE-162.
5.1 DIN-rail Mounting
The DIN-rail bracket is already screwed on the industrial
device. Please refer to the following gures for hanging the
device:
Step 1: Place the upper DIN-rail bracket into the track rst.
1
2
Figure 5-1: DIN-rail mounting
Step 2: Reverse the mounting steps to remove the device
from the track.
5.3 Wall-mount Plate Mounting
To install the industrial device on the wall, please follow the
instructions described below:
Step 1: Remove the DIN-rail bracket from the industrial
device by using a screwdriver.
Step 2: Then screw the wall-mount plate on the rear panel of
the industrial device.
Figure 5-4: Placing Wall-mount Plate on Industrial Device
Step 3: Use the holes in the corners of the wall-mount plate
to hang the industrial device on the wall.
Step 4: To remove the wall-mount plate, reverse the steps
above.
6. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at PLANET Web site rst to check if it
could solve you issue. If you need more support information,
please contact PLANET switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq.php?type=2
Switch support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2019.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
PLANET TECHNOLOGY CORPORATION
e-mail: sales@planet.com.tw http://www.planet.com.tw
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528
EC Declaration of Conformity
For the following equipment:
*Type of Product : Industrial IEEE 802.3at High Power over Ethernet Injector
*Model Number : IPOE-162
* Produced by:
Manufacturer‘s Name : Planet Technology Corp.
Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist.,
New Taipei City 231, Taiwan R.O.C.
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility
Directive on (2014/30/EU).
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 (2015 + AC:2016)
EN 55024 (2010 + A1: 2015)
EN 55035 (2017)
Responsible for marking this declaration if the:
Manufacturer Authorized representative established within the EU
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
R.O.C.
Person responsible for making this declaration
Name, Surname Kent Kang
Position / Title : Director
Taiwan
Jan. 31, 2019
Place
Date
Legal Signature