Quick Guide

– 1 – – 2 –
– 3 – – 4 –
1. Package Contents
Thank you for choosing PLANET IP-based Switched Power Manager. The
Switched IPM provides the useful function of managing power for any
combination to connect with itself.
Open the box of the Switched IPM and carefully unpack it. The box
should contain the following items:
Switched IP Power Manager x 1 Quick Guide x 1
Power Cord x 1 Rack-mounting Kit (Only for IPM-8220) x 1
Note
If there is any item missing or damaged, please contact
the seller immediately.
2. Installation Precautions
Please set the maximum power-off protection allowed by power circuit
as per the rated current information indicated on the device with
reference to the local state rules, safety procedures and disconnector
deviation.
The unit can only be connected to a grounded power outlet or system.
Make sure the total current output of all the connected systems within
the rated current indicated on the device.
The test results of this device may be inaccurate giving unstable
power supply.
Avoid using this device in places near water or moisture environments.
Use the attachments/accessories specied by the manufacturer only.
Please avoid any items or liquids entering the device because their
contact with dangerous voltage points or short-circuit parts may cause
a re or electric shock.
3 Physical Introduction
IPM-4220
Rear Panel :
1
3
4
5 6 7 8 9
2
Front Panel :
15
10 11 12 13 14
16
17
1
System Indicating Light
Slow ashing: Normal operating
Rapid ashing: Normal updating
2
Reset and Warning Indicating Light
3
Temperature/Humidity Port for IPM-ESB Connection
4
Reset Button
5
RJ45 Ethernet Port
6
USB Connected Port (Future Feature)
7
COM2/1
2 Com Ports provided to enable terminal control, API control and
2 mutual cascading
8
Circuit Breaker Protection
9
Power Inlet
10
Power On/Off Switch
11
Power Outlet
Note: The maximum output current is 16 amps.
12
LCD Panel
To display total current, voltage and IP
13
Switch/Set button
Provide LCD panel in order to switch the total current and IP; set
alarm current
14
IP Indicating Light
Lights remaining lit: IP displaying
Slow ashing: Max. current of alarm occurrence
15
Alarm Indicating Light
Lights remaining lit: Alarm has occurred
Slow ashing: There was current overloading
16
Buzzering
17
Power Outlet Indicating Light
Panel Operation
The rst mode of LCD is total current, switching with the Switch/Set
button to show the regular sequence of total current, max. current and
IP shown below:
0.0
0.0
192
168
010
001
Total Current
IP Display
IP Display Max. Current
IP Display IP Display
Alarm and IP indicating light
will not flash.
IP indicating light is flashing
because of overload.
■ IP indicating light remaining lit.
■ IP indicating light remaining lit.
IP indicating light remaining lit.
■ IP indicating light remaining lit.
IP indicating light is flashing.
1
33
33
2
1
LCD menu shows the total current. è Hold the Switch/Set button
for 3 seconds with a long beep to enter alarm current setting. è
Press the Switch/Set button to increase the alarm current by 0.5A
in each press. è Hold the Switch/Set button for 3 seconds with a
“beep” to save the setting.
2
Press the Switch/Set button and shows the maximum current.
è Hold the Switch/Set button for 3 seconds with a long beep to
adjust to a zero point.
3
Press the Switch/Set button to switch the display of each IP
address.
IPM-8220
Rear Panel :
1
3
4
5 6 7 8 9
2
Front Panel :
14
10 11 12 13
1516
1
System Indicating Light
Slow ashing: Normal operating
Rapid ashing: Normal updating
2
Reset and Warning Indicating Light
3
Temperature/Humidity Port for IPM-ESB Connection
IPM-4220/IPM-8220
Quick Installation Guide
IP-based 4-/8-port Switched