DC
Power Line (DC)
1000BASE-SX/LX Fiber-optic
1000
PoE
1000BASE-T UTP with PoE
100m
550m / 120km550m / 120km
IGUP-1205AT
Power
Data
Power
Data
Data
PoE
IP Speed Dome 
Wi-Fi AP
Monitoring 
Center
IGUP-2205AT
1000
Fiber Switch
PoE
PoE
PoE
DC 12~56V
Power
DC
DC 12~56V
Power
DC
1000
Digital Signage
Customer Support
Thank you for purchasing PLANET products. You can browse our 
online  FAQ  resource  on  PLANET  web  site  rst  to  check  if  it  could 
solve your issue. If you need more support information, please 
contact PLANET support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq.php
Support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2019.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
■GigabitFiberInterface
LED Color Function
Fiber
LNK/ACT
Green
Lights to indicate that the ber optic port 
is successfully connecting to the network at 
1000Mbps.
Blinks to indicate the ber optic port is 
receiving or sending data.
Amber
Lights to indicate that the ber optic port 
is successfully connecting to the network at 
100Mbps.
Blinks to indicate the ber optic port is 
receiving or sending data.
3.3  Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of 
Industrial PoE++ Media Converter is used for two 12-56V DC 
redundant power inputs. Please follow the steps below to insert the 
power wire.
Caution
When performing any of the procedures like inserting 
the wires or tightening the wire-clamp screws, make 
sure the power is OFF to prevent from getting an 
electric shock.
3.4  Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block 
connector as the picture shows below. Inserting the wires, the 
Industrial Ethernet Extender will detect the fault status of the 
power failure and then forms an open circuit. The following 
illustration shows an application example for wiring the fault alarm 
contacts.
1 2 3 4 5 6
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be in 
the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V DC, 1A.
3.5 GroundingtheDevice
Users  MUST complete grounding wired with the device; otherwise, 
a sudden lightning could cause fatal damage to the device. EMD 
(Lightning) DAMAGE IS NOT CONVERED UNDER WARRANTY.
1. Insert positive and negative DC power wires into contacts 1 and 
2 for POWER 1, or 5 and 6 for Power 2.
Max. fault loading: 24V, 1A
V1+
V2+
PWR1
PWR2Fault
DC Input:
12-56V , 6A max.
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from 
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
Note
1. The wire gauge for the terminal block should be in 
the range between 12 and 24 AWG
2. The DC power input range is 12-56V DC.
4. Hardware Installation
This section describes the functionalities of the Industrial PoE++ 
Media Converter’s components and guides you to installing it on 
the DIN rail and wall. Please read this chapter completely before 
continuing.
Note
This following picture tells the user how to install the 
device, and the device is not IGUP-1205AT or IGUP-
2205AT.
4.1  DIN-rail Mounting Installation
1
2
4.2  Wall-mount Plate Mounting
4.3  Side Wall-mount Plate Mounting
Caution
You must use the screws supplied with the wall-
mounting brackets. Damage caused to the parts by 
using incorrect screws would invalidate your warranty.
5.FiberandPoEInstallation
The  IGUP-1205AT/IGPT-2205AT  is  exible  enough  to  extend  the 
distance from 550m to 120km. It depends on the 1000BASE-X 
or 100BASE-FX SFP transceivers. The SFP transceivers are 
hot-pluggable and hot-swappable. You can plug in and out the 
transceiver to/from any SFP port without having to power down the 
Industrial 802.3bt PoE++ Media Converter.
If there is any IEEE 802.3af/IEEE 802.3at/IEEE 802.3bt devices 
needed to power on, the IGUP-1205AT/IGUP-2205AT can provide 
you a way to supply power for this Ethernet device conveniently 
and easily.
The IGUP-1205AT/IGUP-2205AT needs 12-56V DC input and it 
injects the DC power into the pin of the twisted pair cable (Pins 1, 
2, 3 and 6).