User's Manual
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
Note
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. The DC power input range is 12V ~ 48V DC and
supports 24V AC
3. Use one power input when using 24V AC
3.4 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. When inserting the wires,
the Industrial Gigabit Media Converter will detect the fault status
of the power failure and then forms an open circuit. The following
illustration shows an application example for wiring the fault alarm
contacts.
Fault Alarm Contacts
Alarm
1 2 3 4 5 6
The Fault Alarm Contacts are energized
(CLOSE) for normal operation and will
OPEN when failure occurs
Note
1. The wire gauge for the terminal block should be in
the range of 12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A
currents.
4.1 DIN-rail Mounting Installation
1
2
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting
Caution
You must use the screws supplied with the wall-
mounting brackets. Damage caused to the parts by
using incorrect screws would invalidate your warranty.
3.5 Grounding the Device
Users MUST complete grounding wired with the device; otherwise,
a sudden lightning could cause fatal damage to the device. EMD
(Lightning) DAMAGE IS NOT CONVERED UNDER WARRANTY.
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V
, 1A max.
AC Input: 24V
, 0.6A max.
V1+ V2+
PWR1
PWR2Alarm
1 2 3 4 5 6
Earth Ground
4. Installation
This section describes the functionalities of the Industrial Gigabit
Media Converter’s components and guides how to install it on
the DIN-rail and wall. Basic knowledge of networking is assumed.
Please read this chapter completely before continuing.
Note
This following pictures show the user how to install
the device, and the device is not IGT-805AT.
5. Link Fault Passthrough
The LFP function includes Link Loss Carry Forward (LLCF), Link Loss
Return (LLR) and turned on by chipset default. LLCF and LLR can
immediately alarm administrators the issue of the link media and
provide ecient solution to monitor the net.
IP Camera
LFP
Enabled
LFP
Enabled
Copper Cable Copper Cable
Monitoring Center
IP Camera
Fiber Cable
LFP
Enabled
LFP
Enabled
Copper Cable
Copper Cable
Monitoring Center
Copper Link Broken
1
Copper
Link Down
5
LFP disconnects
Fiber Link
2
LFP disconnects
Copper Link
4
Fiber Link Down
3
1000
1000
Fiber Cable
Remote Link
Broken
Remote Link
Normal
1000BASE-SX/LX Fiber-optic
1000
1000BASE-T UTP
Note
LFP function is turned on by chipset default and this
feature cannot be turned off. Please assure both TP
and Fiber port connections have established to enable
both TP and Fiber connections to link up.
Customer Support
Thank you for purchasing PLANET products. You can browse our
online FAQ resource on PLANET web site rst to check if it could
solve your issue. If you need more support information, please
contact PLANET switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2021.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.