Connection to the Managed Switch requires UTP Category 5e network cabling with RJ45 tips. For more
information, please see the Cabling Specification in Appendix A.
Step 5: Supply power to the Industrial Managed Switch.
Connect one end of the power cable to the Industrial Managed Switch.
Connect the power plug of the power cable to a standard wall outlet.
When the Industrial Managed Switch receives power, the Power LED should remain solid Green.
2.2.2 Rack Mounting
To install the Industrial Managed Switch in a 19-inch standard rack, please follow the instructions described below.
Step 1: Place the Industrial Managed Switch on a hard flat surface, with the front panel positioned towards the front side.
Step 2: Attach the rack-mount bracket to each side of the Industrial Managed Switch with supplied screws attached to the
package.
Figure 2-2-2 shows how to attach brackets to one side of the Industrial Managed Switch.
Figure 2-2-2 Attach Brackets to the Industrial Managed Switch.
You must use the screws supplied with the mounting brackets. Damage caused to the parts by
using incorrect screws would invalidate the warranty.
Step 3: Secure the brackets tightly.
Step 4: Follow the same steps to attach the second bracket to the opposite side.
Step 5: After the brackets are attached to the Industrial Managed Switch, use suitable screws to securely attach the brackets to
the rack, as shown in Figure 2-2-3.