(V3) User Manual

Table Of Contents
User’s Manual of IGSW-24040T
protocol.
InNUcastPkts: The number of broad-cast and multi-cast packets delivered
to a higher-layer protocol.
InDiscards: The number of inbound packets that are discarded even the
packets are normal.
InErrors: The number of inbound packets that contains errors preventing
them from being deliverable to a higher-layer protocol.
InUnknownProtos: the number of the inbound packets that is discarded
because of the unknown or un-support protocol.
OutOctets: The number of octets transmitted out of the interface , including
framing characters.
OutUcastPkts: The number of uni-cast packets that request to transmit.
OutNUcastPkts: The number of broad-cast and multi-cast packets that
requests to transmit.
OutDiscards: The number of outbound packets that is discarded event the
packets are normal.
OutErrors: The number of outbound packets that could not be transmitted
because of errors.
OutQLen: The length of the output packet queue (in packets).
The method of sampli
ng the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly.
Delta: Calculate the difference between samples (default).
Sample Ty
pe
The value of the st
atistic during the last sampling period.
Value
The method of sampli
ng the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
RisingTrigger alarm when the first value is larger than the rising threshold.
FallingTrigger alarm when the first value is less than the falling threshold.
RisingOrFallingTrigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
S
tartup Alarm
Rising thresh
old value (-2147483648-2147483647).
Rising Threshold
Rising eve
nt index (1-65535).
Rising Index
Falling thresh
old value (-2147483648-2147483647)
Falling Threshold
Falling eve
nt index (1-65535).
Falling Index
Buttons
: Click to add a new community entry.
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
324