User’s Manual of IGSW-24040T
loop is detected (and the port action shuts down the port). Valid values are 0 to
604800 seconds (7 days). A value of zero will keep a port disabled (until next
device restart).
Port Configuration
Object Description
The s
witch port number of the port.
Port
Controls
whether loop protection is enabled on this switch port.
Enable
Configures th
e action performed when a loop is detected on a port. Valid values
are Shutdown Port, Shutdown Port and Log or Log Only.
Action
Controls
whether the port is actively generating loop protection PDU's, or
whether it is just passively looking for looped PDU's.
Tx Mode
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
4.16.2 Loop Protection Status
This page displays the loop protection port status of the switch; screen in Figure 4-16-2 appears.
Figure 4-16-2: Loop Protection Status Screenshot
The page includes the following fields:
Object Description
The Industrial Mana
ged Switch port number of the logical port.
Port
The currentl
y configured port action.
Action
The currentl
y configured port transmit mode.
Transmit
The number of loop
s detected on this port.
Loops
The current loo
p protection status of the port.
Status
Whether a lo
op is currently detected on the port.
Loop
Time of Last Loop
The time of the last loop event detected.
321