387
4.6.1.5 Ethernet Ring Protocol Switch
This page allows the user to configure the ERPS by wizard; screen in Figure 4-6-1-5 appears.
Figure 4-6-1-5: Ring Wizard page screenshot
The page includes the following fields:
Object Description
All Switch Numbers Set all the switch numbers for the ring group. The default number is 3 and
maximum number is 30.
Number ID The switch where you are requesting ERPS.
Port Configures the port number for the MEP.
VLAN Set the ERPS VLAN.
Buttons
: Click to configure ERPS.
: Click to save changes.