2.1.6 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial Gigabit Ethernet Switch will detect the fault status of the
power failure, or port link failure and then forms an open circuit. The
following illustration shows an application example for wiring the fault
alarm contacts.
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 30V, max. 3A
currents.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
2.2 Mounting Installation
This section describes how to install the Industrial Gigabit Ethernet
Switch and make connections to it. Please read the following topics and
perform the procedures in the order being presented.