User's Manual

Table Of Contents
Users Manual of IGS-801M
76
Pkts158to255Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Pkts256to511Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Pkts512to1023Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Pkts1024to1518Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Sample Interval
Sample interval (12147483647)
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly (default).
Delta: Calculate the difference between samples.
Rising Threshold
Rising threshold value (0–2147483647)
Falling Threshold
Falling threshold value (0–2147483647)
Rising Event
Event to fire when the rising threshold is crossed
Falling Event
Event to fire when the falling threshold is crossed
Owner
Specify an owner for the alarm
Buttons
: Click to apply changes.
Figure 4-2-44: RMON Alarm Status Page Screenshot