10/100/1000BASE-T Copper, RJ45 twisted-pair: Up to 100 meters.
Reset Button
On the bottom of the IGS-801M, the reset button is designed to reboot the Industrial Managed Switch without turning off
and on the power. The following is the summary table of the reset button functions:
RESET
Figure 2-2 Bottom Panel of IGS-801M
Reset Button Pressed and Released Function
< 5 sec: System Reboot Reboot the Industrial Managed Switch.
> 5 sec: Factory Default
Reset the Industrial Managed Switch to Factory Default
configuration. Industrial Managed Switch will then reboot and
load the default settings shown below:
Default username: admin
Default password: admin
Default IP address: 192.168.0.100
Subnet mask: 255.255.255.0
Default gateway: 192.168.0.254
2.1.2 LED Indications
The front panel LEDs indicate instant status of port links, data activity and system power; it helps monitor and troubleshoot when
needed.
System/Alert
LED Color Function
Lights
Power 1 is active
P1 Green
Off
Power 1 is inactive
Lights
Power 2 is active
P2 Green
Off
Power 2 is inactive
Lights
Indicates neither Power 1 nor Power 2 has power
FAULT Green
OFF
No failure