Quick Guide

6
Tightenthewire-clampscrewsforpreventingthewiresfromloosening.
1 2 3 4 5 6
V+ V- V+ V-
Power 1 Power 2
Figure 3-2: The pin of 6-contact terminal block connector
Note
1. The wire gauge for the terminal block should be in the range
from 12 to 24 AWG.
2.Please check the wire AWG Ampere specification before
connectingPLANETIndustrialManagedSwitch.
3.1 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden
lightning could cause fatal damage to the device.
DO0DO1 DI0GNDGND
PWR1
PWR2
Alarm
DC Input:
48-54V , 8A max.
Max. Fault Alarm Loading: 24V, 1A
Dual power input is required
for maximum PoE loading.
Refer to user’s manual for
more details.
DI1
1 2 3 4 5 6
1 2 3 4 5 6
Earth Ground