Datasheet
2
IGS-6329-8UP2S2X
– Per port PoE function enable/disable
– PoE admin-mode control
– PoE port power feeding priority
– Per PoE port power limit
– PD classication detection
– PoE extend mode control to support power feeding up to a
distance of up to 160 meters
• Intelligent PoE features
– Temperature threshold control
– PoE usage threshold control
– PD alive check
– PoE schedule
Layer 3 IP Routing Features
• IP dynamic routing protocol supports RIPv2, OSPFv2 and
OSPFv3
• IPv4/IPv6 hardware static routing
• Routing interface provides per VLAN routing mode
Layer 2 Features
• High performance of Store-and-Forward architecture, and runt/
CRC ltering eliminates erroneous packets to optimize the
network bandwidth
• Storm Control support
– Broadcast/Multicast/Unicast
• Supports VLAN
– IEEE 802.1Q tagged VLAN
– Supports provider bridging (IEEE 802.1ad VLAN Q-in-Q)
– Private VLAN Edge (PVE)
– Protocol-based VLAN
– MAC-based VLAN
– Voice VLAN
– GVRP (GARP VLAN Registration Protocol)
• Supports Spanning Tree Protocol
– IEEE 802.1D Spanning Tree Protocol (STP)
– IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
– IEEE 802.1s Multiple Spanning Tree Protocol (MSTP),
spanning tree by VLAN
– BPDU Guard
• Supports Link Aggregation
– 802.3ad Link Aggregation Control Protocol (LACP)
– Cisco ether-channel (static trunk)
– Maximum 4 trunk groups with 4 ports per trunk group
– Up to 40Gbps bandwidth (duplex mode)
• Provides port mirror (many-to-1)
802.3bt PoE++ and Advanced PoE Power Output Mode Management
To meet the demand of various powered devices consuming stable PoE power, the
IGS-6329 PoE++ Switch series provides ve different PoE power output modes for
selection.
■ 90W 802.3bt PoE++ Power Output Mode
■ 95W UPOE/PoH Power Output Mode
■ 60W Force Power Output Mode
■ 30W End-span PoE Power Output Mode
■ 30W Mid-span PoE Power Output Mode
Convenient and Smart ONVIF Devices with Detection Feature
PLANET has newly developed an awesome feature -- ONVIF Support -- which is
specifically designed for co-operating with video IP surveillances. From the IGS-
6329 PoE++ Switch series GUI, clients just need one click to search and show all
of the ONVIF devices via network application.
In addition, clients can upload floor plans to the switch, allowing to locate
surveillance devices for easier inspection and planning. Moreover, clients can
get real-time surveillance’s information and online/offline status, and also allows
cameras PoE reboot control from GUI.
Intelligent Alive Check for Powered Device
The IGS-6329 PoE++ Series can be configured to monitor connected PD’s status
in real time via ping action. Once the PD stops working and responding, the IGS-
6329 PoE++ Series will recycle the PoE port power and bring the PD back to work.
It also greatly enhances the reliability in that the PoE port will reset the PD power,
thus reducing administrator’s management burden.
60W 90W
802.3bt
Type 3
802.3bt
Type 4
802.3at
30W
Speed Dome
Thin Client
90-95W
PoE Lighting
IGS-6329-8U P2S2X
PoE PD Alive Check
Restart PoE Device
Step 3
Checking alive status for 3 times
Step 2
No Response!
Ping Request
PoE Device Status Good!!
Step 1
Ping Request
Ping Echo