Datasheet

2
IGS-6329-8UP2S2X
Per port PoE function enable/disable
PoE admin-mode control
PoE port power feeding priority
Per PoE port power limit
PD classication detection
PoE extend mode control to support power feeding up to a
distance of up to 160 meters
Intelligent PoE features
Temperature threshold control
PoE usage threshold control
PD alive check
PoE schedule
Layer 3 IP Routing Features
IP dynamic routing protocol supports RIPv2, OSPFv2 and
OSPFv3
IPv4/IPv6 hardware static routing
Routing interface provides per VLAN routing mode
Layer 2 Features
High performance of Store-and-Forward architecture, and runt/
CRC ltering eliminates erroneous packets to optimize the
network bandwidth
Storm Control support
Broadcast/Multicast/Unicast
Supports VLAN
IEEE 802.1Q tagged VLAN
Supports provider bridging (IEEE 802.1ad VLAN Q-in-Q)
Private VLAN Edge (PVE)
Protocol-based VLAN
MAC-based VLAN
Voice VLAN
GVRP (GARP VLAN Registration Protocol)
Supports Spanning Tree Protocol
IEEE 802.1D Spanning Tree Protocol (STP)
IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
IEEE 802.1s Multiple Spanning Tree Protocol (MSTP),
spanning tree by VLAN
BPDU Guard
Supports Link Aggregation
802.3ad Link Aggregation Control Protocol (LACP)
Cisco ether-channel (static trunk)
Maximum 4 trunk groups with 4 ports per trunk group
Up to 40Gbps bandwidth (duplex mode)
Provides port mirror (many-to-1)
802.3bt PoE++ and Advanced PoE Power Output Mode Management
To meet the demand of various powered devices consuming stable PoE power, the
IGS-6329 PoE++ Switch series provides ve different PoE power output modes for
selection.
90W 802.3bt PoE++ Power Output Mode
95W UPOE/PoH Power Output Mode
60W Force Power Output Mode
30W End-span PoE Power Output Mode
30W Mid-span PoE Power Output Mode
Convenient and Smart ONVIF Devices with Detection Feature
PLANET has newly developed an awesome feature -- ONVIF Support -- which is
specifically designed for co-operating with video IP surveillances. From the IGS-
6329 PoE++ Switch series GUI, clients just need one click to search and show all
of the ONVIF devices via network application.
In addition, clients can upload floor plans to the switch, allowing to locate
surveillance devices for easier inspection and planning. Moreover, clients can
get real-time surveillance’s information and online/offline status, and also allows
cameras PoE reboot control from GUI.
Intelligent Alive Check for Powered Device
The IGS-6329 PoE++ Series can be configured to monitor connected PD’s status
in real time via ping action. Once the PD stops working and responding, the IGS-
6329 PoE++ Series will recycle the PoE port power and bring the PD back to work.
It also greatly enhances the reliability in that the PoE port will reset the PD power,
thus reducing administrator’s management burden.
60W 90W
802.3bt
Type 3
802.3bt
Type 4
802.3at
30W
Speed Dome
Thin Client
90-95W
PoE Lighting
IGS-6329-8U P2S2X
PoE PD Alive Check
Restart PoE Device
Step 3
Checking alive status for 3 times
Step 2
No Response!
Ping Request
PoE Device Status Good!!
Step 1
Ping Request
Ping Echo