User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web page
- 4.2 System
- 4.2.1 Management
- 4.2.1.1 System Information
- 4.2.1.2 IP Configuration
- 4.2.1.3 IP Status
- 4.2.1.4 Users Configuration
- 4.2.1.5 Privilege Levels
- 4.2.1.6 NTP Configuration
- 4.2.1.6.1 System Time Correction Manually
- 4.2.1.7 Time Configuration
- 4.2.1.8 UPnP
- 4.2.1.9 DHCP Relay
- 4.2.1.10 DHCP Relay Statistics
- 4.2.1.11 CPU Load
- 4.2.1.12 System Log
- 4.2.1.13 Detailed Log
- 4.2.1.14 Remote Syslog
- 4.2.1.15 SMTP Configuration
- 4.2.1.16 Fault Alarm
- 4.2.1.17 Digital Input/Output
- 4.2.2 Simple Network Management Protocol
- 4.2.3 RMON
- 4.2.4 DHCP server
- 4.2.5 Industrial Protocol
- 4.2.1 Management
- 4.3 Switching
- 4.3.1 Port Management
- 4.3.2 Link Aggregation
- 4.3.3 VLAN
- 4.3.3.1 VLAN Overview
- 4.3.3.2 IEEE 802.1Q VLAN
- 4.3.3.3 VLAN Port Configuration
- 4.3.3.4 VLAN Membership Status
- 4.3.3.5 VLAN Port Status
- 4.3.3.6 Private VLAN
- 4.3.3.7 Port Isolation
- 4.3.3.8 VLAN setting example:
- 4.3.3.8.1 Two Separate 802.1Q VLANs
- 4.3.3.8.2 VLAN Trunking between two 802.1Q aware switches
- 4.3.3.8.3 Port Isolate
- 4.3.3.9 MAC-based VLAN
- 4.3.3.10 IP Subnet-based VLAN Membership Configuration
- 4.3.3.11 Protocol-based VLAN
- 4.3.3.12 Protocol-based VLAN Membership
- 4.3.4 Spanning Tree Protocol
- 4.3.5 Multicast
- 4.3.6 MLD Snooping
- 4.3.7 MVR (Multicast VLAN Registration)
- 4.3.8 LLDP
- 4.3.9 MAC Address Table
- 4.3.10 Loop Protection
- 4.3.11 UDLD
- 4.3.12 GVRP
- 4.3.13 PTP
- 4.3.14 Link OAM
- 4.4 Quality of Service
- 4.5 Security
- 4.6 Ring
- 4.7 Maintenance
- 4.8 Power over Ethernet
- 4.9 ONVIF
- 4.10 Routing
- 4.10.1 IP Configuration
- 4.10.2 IP Status
- 4.10.3 Routing Information Base
- 4.10.4 OSPF
- 4.10.4.1 Global Configuration
- 4.10.4.2 Network Area
- 4.10.4.3 Passive Interface
- 4.10.4.4 Stub Area
- 4.10.4.5 Area Authentication
- 4.10.4.6 Area Range
- 4.10.4.7 Interface Configuration
- 4.10.4.8 Virtual Link
- 4.10.4.9 Global Status
- 4.10.4.10 Area Status
- 4.10.4.11 Neighbor Status
- 4.10.4.12 Interface Status
- 4.10.4.13 Configuration Example of OSPFv4
- 5. SWITCH OPERATION
- 6. TROUBLESHOOTING
- APPENDIX A: Networking Connection
- APPENDIX B : GLOSSARY
User’s Manual of IGS-6325 series
393
• Value
The transmitted value in the OS TLV Value field.
TLV Status:
Display of the last received TLV. Currently only TLV in the CCM is supported.
Object Description
• OUI First
The last received first value in the OUI field.
• OUI Second
The last received second value in the OS TLV OUI field.
• OUI Third
The last received third value in the OS TLV OUI field.
• Sub-Type
The last received value in the OS TLV Sub-Type field.
• Value
The last received value in the OS TLV Value field.
• Last RX
OS TLV was received in the last received CCM PDU.
• CC Port Status - Value
The last received value in the PS TLV Value field.
• CC Port Status - Last
RX
PS TLV was received in the last received CCM PDU.
• CC Interface Status -
Value
The last received value in the IS TLV Value field.
• CC Interface Status -
Last RX
IS TLV was received in the last received CCM PDU.
• Link State Tracking
• Enable
When LST is enabled in an instance, Local SF or received 'isDown' in CCM
Interface Status TLV, will bring down the residence port.
Only valid in Up-MEP. The CCM rate must be 1 f/s or faster.
: Click to refresh the page immediatel y.
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.