Quick Guide

5
3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates an inlet power
socket and consists of one green terminal block connector within 6 contacts. Please
follow the steps below to insert the power wire.
1.Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or
Contacts 5 and 6 for Power 2.
IGS-6325-16P4S:DC48-56V
DI
0 DI
1 DO
0 DO
1
GND
GND
Fault
V1+ V2+1A@24V
DC2DC1
Dual power input is required
for maximum PoE loading.
Refer to user’s manual for
more details.
Input: 48-56V , 7.5A max.
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-1: IGS-6325-16P4S Upper Panel
IGS-6325-8T4X/IGS-6325-8T8S/IGS-6325-8T8S4X:DC12~48V,AC24V
DI1 DO0 DO1DI0 GNDGND
Max. fault loading: 24V, 1A
V1+
V2+
PWR1
PWR2Fault
DC Input: 12-48V , 4A max.
AC Input: 24V
, 2A max.
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-2: IGS-6325-8T4X/IGS-6325-8T8S/IGS-6325-8T8S4X Upper Panell