Figure 4-2-20 Digital Input Control Configuration page Screenshot
The page includes the following fields:
Object Description
Enable
Check the Enable checkbox to enable Digital Input function.
Uncheck the Enable checkbox to disable Digital Input function.
DI Condition
As Digital Input:
Allows user to select High to Low or Low to High. This means a signal received
by system is from High to Low or From Low to High. It will trigger an action that
logs a customize message or issue the message from the switch.
Event Description
Allows user to set a customized message for Digital Input function alarming.
Action
As Digital Input:
Allows user to record alarm message to System log, syslog or issues out via
SNMP Trap or SMTP.
As default SNMP Trap and SMTP are disabled, please enable them first if you
want to issue alarm message via them.
Figure 4-2-20 Digital Output Control Configuration page Screenshot
The page includes the following fields:
Object Description
Enable
Check the Enable checkbox to enable Digital Output function.
Uncheck the Enable checkbox to disable Output function.
Event
As Digital Output: