Industrial L3 Multi-Port Gigabit Managed Ethernet Switch IGS-6325 DIN-rail Series Quick Installation Guide
Table of Contents 1. Package Contents........................................................................................ 3 2. Requirements.............................................................................................. 5 3. Wiring the Power Inputs............................................................................... 6 3.1 Grounding the Device........................................................................... 8 4. Terminal Setup............................................
1. Package Contents Thank you for purchasing PLANET L3 Industrial Managed Switch, IGS-6325 DIN-rail series. The descriptions of these models are as follows: IGS-6325-16P4S Industrial L3 16-Port 10/100/1000T 802.3at PoE + 4-Port 1G/2.5G SFP Managed Ethernet Switch IGS-6325-16T4S Industrial L3 16-Port 10/100/1000T + 4-Port 1G/2.
Open the box of the Industrial Managed Switch and carefully unpack it.
2. Requirements The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management: zz Workstations running Windows XP/2003/2008/Vista/7/8/10, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP Protocols. zz Workstations are installed with Ethernet NIC (Network Interface Card). zz Serial Port Connection (Terminal) The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch indicates an inlet power socket and consists of one green terminal block connector within 6 contacts. Please follow the steps below to insert the power wire. 1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2. IGS-6325-16P4S: DC 48-56V DI 0 DI 1 DO 0 DO 1 GND GND 1 2 3 4 5 6 1 2 3 4 5 6 V1+ 1A@24V V2+ DC1 Fault Input: 48-56V DC2 , 7.5A max.
IGS-6325-8T4X/IGS-6325-8T8S/IGS-6325-8T8S4X: DC 12~48V, AC 24V DI0 DI1 DO0 DO1 GND GND 1 2 3 4 5 6 Max. fault loading: 24V, 1A 1 2 3 4 5 6 V2+ V1+ PWR1 Fault PWR2 DC Input: 12-48V , 4A max. AC Input: 24V , 2A max. Figure 3-3: IGS-6325-8T4X/IGS-6325-8T8S/IGS-6325-8T8S4X Upper Panel IGS-6325-8UP2S/IGS-6325-8UP2S2X: DC 48~56V Dual power input is required for maximum PoE loading. Refer to user’s manual for more details. DI0 DI1 DO0 DO1 GND GND 1 2 3 4 5 6 Max.
2. Tighten the wire-clamp screws for preventing the wires from loosening. 1 2 V+ VPower 1 3 4 5 6 V+ VPower 2 Figure 3-5: The pin of 6-contact terminal block connector 1. The wire gauge for the terminal block should be in the range from 12 to 24 AWG. Note 2. Please check the wire AWG Ampere specification connecting PLANET Industrial Managed Switch. before 3.
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch. IGS Industrial Managed Switch PC/Workstation with Terminal Emulation Software Console 115200,N,8,1 RJ45 to DB9 RS232 Cable Console Port 115200,N,8,1 Serial Port A terminal program is required to make the software connected to the Industrial Managed Switch. 1. Run terminal program on the OS. 2.
4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. Note The following console screen is based on the IGS-6325-16P4S. The display of the IGS-6325 series is the same as that of the IGS6325-16P4S. Then, the following message asks to log in user name and password.
4.2 Configuring IP Address via Console The Industrial Managed Switch is shipped with default IP address shown below: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedure as follows: Display of the Current IP Address 1. At the “#” prompt, enter “show ip interface brief”. IGS-6325-Series # show ip interface brief 2. The screen displays the current IP address shown in Figure 4-2.
The previous command would apply the following settings for the Industrial Managed Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Figure 4-3: Configuring IP Address Screen 4. Repeat step 1 to check if the IP address has changed. 4.3 Storing Current Switch Configuration 1. At the “#” prompt, enter the following command and press .
5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
3. After entering the password, the main screen appears as shown in Figure 5-3. Switch Menu Sub-menu Figure 5-3: Web Main Screen of Industrial Managed Switch The Switch Menu on the top of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. The Switch Menu always contains one or more buttons, such as “System”, “Switching”, “Routing”, “QoS”, “Security”, “PoE”, “Ring”, “ONVIF” and “Maintenance”.
Figure 5-6: Switch Sub-menu Now, you can use the Web management interface to continue the Switch management. Please refer to the user manual for more. Note If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description. 5.2 Saving Configuration via Web To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot. 1.
2. Press the “Save Configuration” button. 3. Or the other way to save the setting is to Click Maintenance, Save Startup Config.
6. Recovering Back to Default Configuration IP address has been changed or admin password has been forgotten – To reset the IP address to the default IP address “192.168.0.100” and the user password to factory default mode (default password is admin), press the hardware-based reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx and default password.
14 5 6 3 4 1 2 13 12 1000 LNK 10/100 LNK ACT ACT 11 20 19 20 10 19 18 17 18 9 17 1G/2.5G LNK 10G LNK Reset Button Reset ACT ACT IGS-6325-8T8S4X Figure 6-3: IGS-6325-8T4X/IGS-6325-8T8S/IGS-6325-8T8S4X Reset Button PoE Usage 320W 3 4 1 2 240W 160W Reset Button 80W 802.
7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: http://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw IGS-6325-DIN-rail Series User’s Manual: https://www.planet.com.