Industrial L3 Multi-Gigabit/10Gigabit Managed Ethernet Switch IGS-6325-4T2X/IGS-6325-5X1T Quick Installation Guide
Table of Contents 1. Package Contents.................................................................................. 3 2. Requirements........................................................................................ 4 3. Wiring the Power Inputs........................................................................ 5 3.1 Grounding the Device...................................................................... 6 4. Terminal Setup....................................................................
1. Package Contents Thank you for purchasing PLANET L3 Multi-Gigabit/10Gigabit Industrial Managed Switch, IGS-6325-4T2X/IGS-6325-5X1T. “Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the above models. The descriptions of these models are shown below: IGS-6325-4T2X Industrial L3 4-Port 2.
2. Requirements The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management: Workstations running Windows XP/2003/2008/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP Protocols. Workstations are installed with Ethernet NIC (Network Interface Card). Serial Port Connection (Terminal) The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch indicates an inlet power socket and consists of one green terminal block connector with 6 contacts. Please follow the steps below to insert the power wire. 1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2. DC 9-48V, AC 24V DI0 DI1 DO0 DO1 GND GND 1 2 3 4 5 6 Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 DC Input: 9-48V AC Input: 24V , 4A max. V1+ , 2A max.
2. Tighten the wire-clamp screws for preventing the wires from loosening. 1 2 V1+ V1Power 1 3 4 5 6 V2+ V2Power 2 Figure 3-2: Power 1 & 2 Pins of Terminal Block Connector 1. The wire gauge for the terminal block should be in the range from 12 to 24 AWG. 2. Please check the AWG Ampere specification before connecting PLANET Industrial Managed Switch. 3.1 Grounding the Device Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device.
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch. IGS Industrial Managed Switch PC/Workstation with Terminal Emulation Software RJ45 to DB9 RS232 Cable Console 115200,N,8,1 Console Port 115200,N,8,1 Serial Port A terminal program is required to make the software connected to the Industrial Managed Switch. 1. Run terminal program on the OS. 2.
4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. Then, the following message asks to log in user name and password. The factory default user name and password are shown as follows as the login screen in Figure 4-1 appears. IGS-6325-5X1T is used as a representative in all the following console screens.
4.2 Configuring IP Address via Console The Industrial Managed Switch is shipped with default IP address shown below: IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 To check the current IP address or assign a new IP address to the Switch, please use the procedure as follows: Display of the Current IP Address 1. At the “#” prompt, enter “show ip interface brief”. IGS-6325-Series # show ip interface brief 2. The screen displays the current IP address shown in Figure 4-2.
Figure 4-3: Configuring IP Address Screen 4. Enter “exit” command twice to return to the global configuration mode. 5. Repeat step 1 to check if the IP address has changed. 4.3 Storing the current switch 1. At the “#” prompt, enter the following command and press . # copy running-config startup-config Figure 4-4: Saving Current Configuration If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately.
5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
2. When the following dialog box appears, please enter the default user name “admin” and password “admin” (or the password you have changed before) as shown in Figure 5-2. Default IP Address: 192.168.0.100 Default Username: admin Default Password: admin Figure 5-2: Login Screen 3. After entering the password, the main screen appears as shown in Figure 5-3.
The Switch Menu on the top of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. The Switch Menu always contains one or more buttons, such as “System”, “Switching”, “Routing”, “QoS”, “Security”, “Ring” and “Maintenance”. Figure 5-4: Switch Menu Figure 5-5: Switch Sub-menu Figure 5-6: Switch Sub-menu Now, you can use the Web management interface to continue the Switch management.
If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description. 5.2 Saving Configuration via Web To save all applied and set the current configuration as a startup configuration, click the “Save” icon, then the startup configuration file will be loaded automatically across a system reboot. 1. Click the Save icon on the top Switch Menu bar. 2. Press the “Save Configuration” button. 3.
6. Restoring Default Configuration IP address has been changed or admin password has been forgotten – To reset the IP address to the default IP address “192.168.0.100” and user password to factory default (default password is admin), press recessed reset button on the front panel for about 10 seconds. After device is rebooted, you can log in the management Web interface within same subnet of 192.168.0.xx with default password.
7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: https://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw Industrial User’s Manual: https://www.planet.com.