Quick Guide
5
3. Wiring DC Power Inputs
The 6-contact terminal block connector on the panel of Industrial Managed Switch
isused for two DCredundant power inputs. Pleasefollowthe steps below to insert
the power wires.
1.Insert positive and negative DC power wires into contacts 1 and 2 for DC
POWER1,or5and6forDCPOWER2.
DI/DO
FaultR.O.
Ring
AC
DC 2
DC 1
DC POWER
ON
Fault DC 2DC 1
OFF
DC Input Range:
24-60V , 1.7A max.
GNDGNDDO 1DO 0DI 1DI 0
Max. fault loading: 24V, 1A
Figure 3-1: 6-contact terminal block connector of IGS-6325-20T4C4X and IGS-6325-20S4C4X
+
FaultDC 1 DC 2
+
DC Input: 48-56V , 11A
Figure 3-2: 6-contact terminal block connector of IGS-6325-24P4X and IGS-6325-24P4S
2.Tightenthewire-clampscrewsforpreventingthewiresfromloosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
Figure 3-3: The pins of 6-contact terminal block connector
Note
The wire gauge for the terminal block should be in the range
between12and24AWG.