User's Manual

Table Of Contents
Users Manual of IGS-6325 series
44
2.1.5 Wiring the DC Power Input
The 6-contact terminal block connector on the front panel of Industrial Managed Switch is used for two DC redundant power
inputs. Please follow the steps below to insert the power wire.
IGS-6325-20T4C4X and IGS-6325-20S4C4X
1. Insert positive/negative DC power wires into Contacts 1 and 2 for DC POWER 1, or 5 and 6 for DC POWER 2.
Figure 2-1-16: IGS-6325-20T4C4X DC power input
2. Tighten the wire-clamp screws for preventing the wires from loosening.
3.
1 2 3 4 5 6
DC 1 DC 2
+ - + -
Figure 2-1-17 6-pin Terminal Block Power Wiring Input for IGS-6325-20T4C4X and IGS-325-20S4C4X
IGS-6325-24P4X and IGS-6325-24P4S
1. Insert positive/negative DC power wires into Contacts 1 and 2 for DC POWER 1, or 5 and 6 for DC POWER 2.
Figure 2-1-18: IGS-6325-24P4X and IGS-6325-24P4S DC power input
2. Tighten the wire-clamp screws for preventing the wires from loosening.