IGS-6325-Series User Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web page
- 4.2 System
- 4.2.1 Management
- 4.2.1.1 System Information
- 4.2.1.2 IP Configuration
- 4.2.1.3 IP Status
- 4.2.1.4 Users Configuration
- 4.2.1.5 Privilege Levels
- 4.2.1.6 NTP Configuration
- 4.2.1.6.1 System Time Correction Manually
- 4.2.1.7 Time Configuration
- 4.2.1.8 UPnP
- 4.2.1.9 DHCP Relay
- 4.2.1.10 DHCP Relay Statistics
- 4.2.1.11 CPU Load
- 4.2.1.12 System Log
- 4.2.1.13 Detailed Log
- 4.2.1.14 Remote Syslog
- 4.2.1.15 SMTP Configuration
- 4.2.1.16 Fault Alarm
- 4.2.1.17 Digital Input/Output
- 4.2.2 Simple Network Management Protocol
- 4.2.3 RMON
- 4.2.4 DHCP server
- 4.2.5 Industrial Protocol
- 4.2.1 Management
- 4.3 Switching
- 4.3.1 Port Management
- 4.3.2 Link Aggregation
- 4.3.3 VLAN
- 4.3.3.1 VLAN Overview
- 4.3.3.2 IEEE 802.1Q VLAN
- 4.3.3.3 VLAN Port Configuration
- 4.3.3.4 VLAN Membership Status
- 4.3.3.5 VLAN Port Status
- 4.3.3.6 Private VLAN
- 4.3.3.6 Port Isolation
- 4.3.3.7 VLAN setting example:
- 4.3.3.7.1 Two Separate 802.1Q VLANs
- 4.3.3.7.2 VLAN Trunking between two 802.1Q aware switches
- 4.3.3.7.3 Port Isolate
- 4.3.3.8 MAC-based VLAN
- 4.3.3.9 IP Subnet-based VLAN Membership Configuration
- 4.3.3.10 Protocol-based VLAN
- 4.3.3.11 Protocol-based VLAN Membership
- 4.3.4 Spanning Tree Protocol
- 4.3.5 Multicast
- 4.3.6 MLD Snooping
- 4.3.7 MVR (Multicast VLAN Registration)
- 4.3.8 LLDP
- 4.3.9 MAC Address Table
- 4.3.10 Loop Protection
- 4.3.11 UDLD
- 4.3.12 GVRP
- 4.3.13 PTP
- 4.4 Quality of Service
- 4.5 Security
- 4.6 Ring
- 4.7 Maintenance
- 5. SWITCH OPERATION
- 6. TROUBLESHOOTING
- APPENDIX A: Networking Connection
- APPENDIX B : GLOSSARY
User’s Manual of IGS-6325 series
17
1.4 Product Features
Physical Port
24-port 10/100/1000BASE-T RJ45 copper
4 100/1000BASE-X mini-GBIC/SFP slots, shared with Port-21 to Port-24 compatible with 100BASE-FX SFP
4 10GBASE-SR/LR SFP+ slots, compatible with 1000BASE-SX/LX/BX SFP
RJ45 to RS232 DB9 console interface for basic management and setup
Hardware Conformance
One 100 to 240V AC or dual 36 to 60V DC power input, redundant power with polarity reverse protect function
Active-active redundant power failure protection
Backup of catastrophic power failure on one supply
Fault tolerance and resilience
19-inch rack-mountable design
IP30 metal case protection
Supports EFT protection for 6000V DC power and 6000V DC Ethernet ESD protection
-40 to 75 degrees C operating temperature
Industrial Protocol
Modbus TCP for real-time monitoring in the SCADA system
Digital Input and Digital Output
2 Digital Input (DI)
2 Digital Output (DO)
Integrates sensors into auto alarm system
Transfers alarm to IP network via email and SNMP trap
Layer 3 IP Routing Features
Supports maximum 128 static routes and route summarization
IP dynamic routing protocol supports OSPFv2
Routing interface provides per VLAN routing mode
Layer 2 Features
High performance of Store-and-Forward architecture, and runt/CRC filtering eliminates erroneous packets to optimize
the network bandwidth
Storm control support
Broadcast/Multicast/Unknown unicast
Supports VLAN
IEEE 802.1Q tagged VLAN
Up to 256 VLANs groups, out of 4096 VLAN IDs
Provides Bridging (VLAN Q-in-Q) support (IEEE 802.1ad)