User's Manual

Table Of Contents
User’s Manual of IGS-604HPT-M12
36
2.2.4 Recovering Back to Default Configuration
IP address has been changed or admin password has been forgotten
1. Power off the Industrial Managed Switch and remove all the existing connections.
2. Use the M12 cable to connect to port 1 and port 2 in the loop topology as shown below:
3. Power on the Industrial Managed Switch and 6 LNK/ACT LEDs will be lit.
4. Resetting Industrial Managed Switch to the factory default is done when 6 LNK/ACT LEDs are lit again.
5. Remove the M12 cable from port 1 and port 2.
6. Reset the Industrial Managed Switch to Factory Default configuration. The Industrial Managed Switch will then reboot and
load the default settings as shown below:
Default Username: admin
Default Password: admin
Default IP Address: 192.168.0.100
Default Subnet Mask: 255.255.255.0
Default Gateway: 192.168.0.254