User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web Page
- 4.2 System
- 4.2.1 Management
- 4.2.1.1 System Information
- 4.2.1.2 IP Configuration
- 4.2.1.3 IP Status
- 4.2.1.4 Users Configuration
- 4.2.1.5 Privilege Levels
- 4.2.1.6 NTP Configuration
- 4.2.1.6.1 System Time Correction Manually
- 4.2.1.7 Time Configuration
- 4.2.1.8 UPnP
- 4.2.1.9 DHCP Relay
- 4.2.1.10 DHCP Relay Statistics
- 4.2.1.11 CPU Load
- 4.2.1.12 System Log
- 4.2.1.13 Detailed Log
- 4.2.1.14 Remote Syslog
- 4.2.1.15 SMTP Configuration
- 4.2.1.16 Fault Alarm
- 4.2.1.17 Digital Input/Output
- 4.2.2 Simple Network Management Protocol
- 4.2.3 RMON
- 4.2.4 DHCP server
- 4.2.5 Industrial Protocol
- 4.2.1 Management
- 4.3 Switching
- 4.3.1 Port Management
- 4.3.2 Link Aggregation
- 4.3.3 VLAN
- 4.3.3.1 VLAN Overview
- 4.3.3.2 IEEE 802.1Q VLAN
- 4.3.3.3 VLAN Port Configuration
- 4.3.3.4 VLAN Membership Status
- 4.3.3.5 VLAN Port Status
- 4.3.3.6 Private VLAN
- 4.3.3.7 Port Isolation
- 4.3.3.8 VLAN setting example:
- 4.3.3.8.1 Two Separate 802.1Q VLANs
- 4.3.3.8.2 VLAN Trunking between two 802.1Q aware switches
- 4.3.3.8.3 Port Isolate
- 4.3.3.9 MAC-based VLAN
- 4.3.3.10 IP Subnet-based VLAN Membership Configuration
- 4.3.3.11 Protocol-based VLAN
- 4.3.3.12 Protocol-based VLAN Membership
- 4.3.4 Spanning Tree Protocol
- 4.3.5 Multicast
- 4.3.6 MLD Snooping
- 4.3.7 MVR (Multicast VLAN Registration)
- 4.3.8 LLDP
- 4.3.9 MAC Address Table
- 4.3.10 Loop Protection
- 4.3.11 UDLD
- 4.3.12 GVRP
- 4.3.13 PTP
- 4.4 Quality of Service
- 4.5 Security
- 4.6 Power over Ethernet (IGS-5225-8P2S2X)
- 4.7 Ring
- 4.8 ONVIF
- 4.9 Maintenance
- 5. SWITCH OPERATION
- 6. TROUBLESHOOTING
- APPENDIX A: Networking Connection
- APPENDIX B : GLOSSARY
User’s Manual of IGS-5225-8T2S2X & 8P2S2X series
350
Please be noticed that if you want to PoE schedule and PoE reboot schedule work
at the same time, please use this function, and don’t use Reboot Only function.
This function offers administrator to reboot PoE device at indicate time if
administrator has this kind of requirement.
• Reboot Only
Allows user to reboot PoE function by PoE reboot schedule. Please be noticed that if
administrator enable this function, PoE schedule will not to set time to profile. This
function is just for PoE port reset at an indicated time.
• Reboot Hour
Allows user to set what hour PoE reboots. This function only for PoE reboot
schedule.
• Reboot Min
Allows user to set what minute PoE reboots. This function only for PoE reboot
schedule.
Buttons
: click to add new rule.
: Click to apply changes
: Check to delete the entry.
4.6.1.8 PoE Alive Check Configuration
The IGS-5225-8P2S2X PoE Switch can be configured to monitor connected PD’s status in real-time via ping action. Once the
PD stops working and without response, IGS-5225-8P2S2X PoE Switch is going to restart PoE port port power, and bring the
PD back to work. It will greatly enhance the reliability and reduces administrator management burden.
This page provides you how to configure PD Alive Check.The screen in Figure 4-6-1-7 appears.
Figure 4-6-1-7: PD Alive Check Configuration Screenshot
The page includes the following fields:
Object Description
• Mode
Allows user to enable or disable per port PD Alive Check function. As default value