User Manual

Table Of Contents
Users Manual of IGS-5225 series
42
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4 5 6
DC 1 DC 2
Figure 2-6 6-Pin Terminal Block Power Wiring Input
Model Name Positive (+) Pin Negative (-) Pin Input Voltage
IGS-5225-4UP1T2S Pin 1/5 Pin 2/6 DC 48~56V
IGS-5225-8P2T2S Pin 1/5 Pin 2/6 DC 48~56V
IGS-5225-4P2S Pin 1/5 Pin 2/6 DC 48~56V
1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG@25 degrees C.
2. When performing any of the procedures like inserting the wires or tightening the wire-clamp screws,
make sure the power is OFF to prevent from getting an electric shock.