37
2.1.5 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial Managed Switch is used for two DC redundant power input.
Please follow the steps below to insert the power wire.
IGS-4215-4P4T/IGS-4215-4P4T2S
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or 5 and 6 for power.
V1- V1 + V2 - V2 +
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
- + - +
Negative (-) Pin Positive (+) Pin
IGS-4215-4P4T/
IGS-4215-4P4T2S
Pin 1/5 Pin 2/6
The wire gauge for the terminal block should be in the range between 12 and 24 AWG.