Users Manual of IGS-4215 Series
32
setting.
Users can use the attached DB9 to RJ45 console cable in the package and connect to the console port on the device.
After the connection, users can run any terminal emulation program (Hyper Terminal, ProComm Plus, Telix, Winterm
and so on) to enter the startup screen of the device.
Reset Button
On the left of the front panel, the reset button is designed to reboot the Industrial Managed Switch without turning off and on
the power. The following is the summary table of reset button functions:
Reset Button Function
Press the reset button for < 5 seconds
for system reboot.
Reboot the Industrial Managed Switch.
Press the reset button for > 5 seconds
for factory default.
Reset the Industrial Managed Switch to Factory Default
configuration. The Industrial Managed Switch
will then reboot
and load the default settings shown below:
Default username: admin
Default password: admin
Default IP address: 192.168.0.100
Subnet mask: 255.255.255.0
Default gateway: 192.168.0.254