Datasheet

IGS-4215-4P4T
3
• MAC Security
Static MAC
MACltering
• PortsecurityforsourceMACaddressentriesltering
• DHCPsnoopingtolterdistrustedDHCPmessages
• Dynamic ARP inspection discards ARP packets with invalid
MAC address to IP address binding
• IPsourceguardpreventsIPspoongattacks
• DoS attack prevention
Management
• IPv4 and IPv6 dual stack management
• Switch Management Interface
Web switch management
Console/Telnet Command Line Interface
SNMP v1 and v2c switch management
SSHv2, TLSv1.2 and SNMP v3 secure access
• SNMP Management
SNMPtrapforinterfaceLinkUpandLinkDownnotication
Four RMON groups (history, statistics, alarms and events)
• User privilege levels control
• Built-in Trivial File Transfer Protocol (TFTP) client
• Static and DHCP for IP address assignment
• System Maintenance
Firmware upload/download via HTTP/TFTP
Congurationupload/downloadthroughHTTP/TFTP
Dual images
Hardware reset button for system reboot or reset to factory
default
• SNTP Network Time Protocol
• Network Diagnostic
Cable diagnostics
ICMPv6/ICMPv4 Remote Ping
SFP-DDM (Digital Diagnostic Monitor)
• Link Layer Discovery Protocol (LLDP) Protocol and LLDP-
MED
• Event message logging to remote syslog server
• PLANET Smart Discovery Utility for deployment management
• PLANET NMS system and CloudViewer for deployment
management
Scheduled Power Recycling
The IGS-4215-4P4T allows each of the connected PoE IP cameras or PoE wireless
access points to reboot at a specific time each week. Therefore, it will reduce the
chanceofIPcameraorAPcrashresultingfrombufferoverow.
PD Alive Check
Restart PoE device if without response
Step
3
Checking alive status for 3 times
Step
2
No Response!
Ping Request
PoE
ON OFF
Restart PoE Device
Step
4
PoE Device Status Good!!
Step
1
Ping Request
Ping Echo
Alarm Notification
IP Camera
S M T W T F S
AP Router IP Phone
PoE lighting
Door Phone
Automatically Reboot
PoE Schedule for Energy Saving
Under the trend of energy saving worldwide and contributing to environmental protection,
the IGS-4215-4P4T can effectively control the power supply besides its capability of
giving high watts power. The “PoE schedule” function helps you to enable or disable
PoEpowerfeedingforeachPoEportduringspeciedtimeintervalsanditisapowerful
function to help SMBs or enterprises save power and budget. It also increases security
by powering off PDs that should not be in use during non-business hours.
Total Consumption of 36 watts/hr Save 24 watts/hr during off-business hours
Total Saved = 10800watts/month
6 Watts 6 Watts 12 Watts 12 Watts
PoE Schedule
08:00~17:00 17:00~08:00
6 Watts 6 Watts 12 Watts 12 Watts
OFF OFF OFF
ON ON ON ON ON