Industrial 16-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Gigabit Ethernet Switch IGS-4215-16T2S Quick Installation Guide
Table of Contents 1. Package Contents........................................................................................ 3 2. Requirements.............................................................................................. 4 3. Wiring the Power Inputs............................................................................... 5 4. Terminal Setup............................................................................................ 6 4.1 Logging on to the Console......................
1. Package Contents Thank you for purchasing PLANET Industrial L2/L4 Managed Gigabit Ethernet Switch, IGS-4215-16T2S. “Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the IGS-4215-16T2S. Open the box of the Industrial Managed Switch and carefully unpack it.
2. Requirements The Industrial Managed Switch provides local and remote login interface for management purposes. The following equipment is necessary for further management: zz Workstations running Windows XP/2003/Vista/7/8/10/2008/10, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols. zz Serial Port Connection (Terminal) The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch consists of one terminal block connector within 6 contacts for two redundant power inputs and fault alarm. Please follow the steps below to insert the power wire. 1. Insert positive/negative DC power wires into contacts 1 and 2 for Power 1 or 5 and 6 for Power 2. Max. fault loading: 24V, 1A 1 2 3 4 5 6 V1+ PWR1 V2+ Fault PWR2 DC Input: 12- 48V , 1.5A max. AC Input: 24V , 1A max.
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to the RJ45 type serial (console) port of the Industrial Managed Switch. PC / Workstation with Terminal Emulation Software Managed Switch RS232 to RJ45 Cable Serial Port RJ45 Console Port Figure 4-1: Industrial Managed Switch Console Connectivity A terminal program is required to make the software connection to the Industrial Managed Switch. 1. Run terminal program on the OS. 2.
4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. Then, the following message asks to login user name and password. The factory default user name and password are shown as follows, and the login screen in Figure 4-1 appears.
4.2 Configuring IP Address via the Console The Industrial Managed Switch is shipped with default IP address as follows: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Industrial Managed Switch, please use the procedures as follows: Display of current IP address 1. At the “IGS-4215-16T2S#” prompt, enter “show ip”. 2. The screen displays the current IP address, subnet mask and gateway as shown in Figure 4-2.
Figure 4-3: Configuring IP Address Screen 3. Repeat Step 1 to check if the IP address has changed. If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed Switch through the new IP address. 4.3 Storing Current Switch Configuration At the “IGS-4215-16T2S#” prompt, enter “copy running-config startup-config” as shown in Figure 4-4.
5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
5.1 Logging in to the Industrial Managed Switch 1. Use Internet Explorer 8.0 or above Web browser and enter IP address https://192.168.0.100 to access the Web interface. 2. When the following dialog box appears, please enter the default user name and password “admin”. The login screen in Figure 5-2 appears. Default IP Address: 192.168.0.100 Default Username: admin Default Password: admin Figure 5-2: Web Login Screen 3. After entering the username and password, the main screen appears as Figure 5-3 shows.
The Switch Menu on the left of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. Figure 5-4: Switch Menu Now, you can use the Web management interface to continue the Switch management. Please refer to the user’s manual for more.
5.2 Saving Configuration via the Web To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot. 1. Click “Save > Save Configurations to FLASH” to log in to the “Configuration Manager” page. 2. Press the “Apply” button to save running configuration to start up configuration.
6. Recovering Back to Default Configuration IP Address has been changed or admin password has been forgotten – To reset the IP address to the default IP Address “192.168.0.100” or reset the login password to default value, press the hardware reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx.
7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: https://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw IGS-4215 Series User’s Manual: https://www.planet.com.tw/en/support/download.