2.2.5 Removing the SFP Transceiver
1. Make sure there is no network activity by consulting or checking with the network administrator, or through the
management interface of the switch/converter (if available) to disable the port in advance.
2. Remove the fiber optic cable gently.
3. Turn the lever of the MGB / MFB module to a horizontal position.
4. Pull out the module gently through the lever.
Figure 2-2-5: Pulling out the SFP Transceiver Module
Never pull out the module without pulling the lever or the push bolts on the module. Directly pulling
out the module with force could damage the module and SFP module slot of the device.