1. Package Contents
Thank you for purchasing PLANET Industrial Multi-port
10/100/1000T Gigabit Ethernet Switch, IGS-1600T/IGS-1820TF.
In the following sections, the term “Industrial Ethernet
Switch” means the IGS-1600T or IGS-1820TF.
Open the box of the Industrial Ethernet Switch and carefully
unpack it. The box should contain the following items:
Industrial Ethernet
Switch x 1
User’s Manual x 1 RJ45 Dust Cap x 16
DIN-rail Kit Wall-mount Kit SFP Dust Cap x 2
(IGS-1820TF only)
If any of these are missing or damaged, please contact your
dealer immediately; if possible, retain the carton including the
original packing material, and use them again to repack the
product in case there is a need to return it to us for repair.
2.2 LEDDenition:
System
LED Color Function
P1 Green Lights
Lights to indicate power input 1
has power.
P2 Green Lights
Lights to indicate power input 2
has power.
Fault Red Lights
Lights to indicate that AC or DC
power has failed.
Per 10/100/1000BASE-T Port
LED Color Function
1000
LNK/ACT
Green
Lights
To indicate the link through that
port is successfully established at
1000Mbps.
Blinks
To indicate that the switch is
actively sending or receiving data
over that port.
10/100
LNK/ACT
Amber
Lights
To indicate the port is successfully
established at 10/100Mbps.
Blinks
To indicate that the Switch is
actively sending or receiving data
over that port.
2.5 WiringtheFaultAlarmContact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial Ethernet Switch will detect the fault status of the
power failure, and then forms an open circuit. The following
illustration shows an application example for wiring the fault
alarm contacts.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be
in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A
currents.
2.4 WiringthePowerInputs
The 6-contact terminal block connector on the top panel of
Industrial Ethernet Switch is used for two redundant power
inputs. Please follow the steps below to insert the power wire.
Caution
When performing any of the procedures like
inserting the wires or tightening the wire-clamp
screws, make sure the power is OFF to prevent
from getting an electric shock.
Insert positive and negative DC power wires into contacts 1
and 2 for POWER 1, or contacts 5 and 6 for POWER 2.
Fault
V1+ V2+
PWR2PWR1
Max. fault loading: 24V, 1A
DC Input: 12-48V , 1.5A max.
AC
Input: 24V , 1A max.
1 2 3 4 5 6
2.HardwareIntroduction
2.1 SwitchFrontPanel
The front panel of the Industrial Ethernet Switch consists of
Ethernet interfaces and LED indicators.
Front View
IGS-1600T
FaultP2P1
1
3
5
7
2
4
6
8
9
11
13
15
10
12
14
16
ACT
1000 LNK
ACT
10/100 LNK
IGS-1820TF
FaultP2P1
1
3
5
7
2
4
6
8
9
11
13
15
10
17
12
14
16
ACT
1000 LNK
ACT
10/100 LNK
1000 LNK/ACT
18
Figure1:
IGS-1600T Front View
Figure2:
IGS-1820TF Front View
Per1000BASE-XSFPPort
(Port-17andPort-18ofIGS-1820TF)
LED Color Function
LNK/ACT Green
Lights
To indicate the port is successfully
established at 1000Mbps.
Blinks
To indicate that the Switch is
actively sending or receiving data
over that port.
2.3 SwitchUpperPanel
The upper panel of the Industrial Ethernet Switch consists of
one terminal block connector within two power input and one
relay output.
Fault
V1+ V2+
PWR2PWR1
Max. fault loading: 24V, 1A
DC Input: 12-48V , 1.5A max.
AC
Input: 24V , 1A max.
1 2 3 4 5 6
Figure3:IGS-1600T and IGS-1820TF Top View
Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
Note
1. The wire gauge for the terminal block should be
in the range between 12 and 24 AWG.
2. The power input range is DC 12V ~ 48V and
supports AC 24V.
3. Use one power input when using AC 24V.
2.6 GroundingtheDevice
Users MUST complete grounding wired with the device;
otherwise, a sudden lightning could cause fatal damage to the
device.
Fault
V1+ V2+
PWR2PWR1
Max. fault loading: 24V, 1A
DC Input: 12-48V , 1.5A max.
AC
Input: 24V , 1A max.
1 2 3 4 5 6
Earth Ground
Note
EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
WARRANTY.