User Manual

Table Of Contents
User’s Manual of IGS-10080MFT
PTP Servo
Description:
Set or show PTP clock servo data.
Syntax:
PTP Servo <clockinst> [<displaystates>] [<ap_enable>] [<ai_enable>] [<ad_enable>] [<ap>] [<ai>] [<ad>]
Parameters:
<clockinst>: clock instance number [0..3]
<displaystates>: The displaystates parameter takes the following values:
true: Display clock state and measurements
false: don't display
<ap_enable>:
true: Enable the 'P' component in regulator
false: Disable the 'P' component in regulator
<ai_enable>:
true: Enable the 'I' component in regulator
false: Disable the 'I' component in regulator
<ad_enable>:
true: Enable the 'D' component in regulator
false: Disable the 'D' component in regulator
<ap>: [1..1000] 'P' component in regulator
<ai>: [1..10000] 'I' component in regulator.
<ad>: [1..10000] 'D' component in regulator.
PTP SlaveTableUnicast
Description:
Show the Unicast slave table of the requested unicast masters.
Syntax:
PTP SlaveTableUnicast <clockinst>
Parameters:
<clockinst>: clock instance number [0..3]
547