User Manual

Table Of Contents
User’s Manual of IGS-10080MFT
<leap61>: The leap61 parameter takes the following values:
false: no leap61 in current day
true: last minute of current day contains 61 sec.
<timetrac>: The timetraceable parameter takes the following values:
false: timing is not traceable
true: timing is traceable.
<freqtrac>: The freqtraceable parameter takes the following values:
False: frequency is not traceable
true: frequency is traceable.
<ptptimescale>: The timescale parameter takes the following values:
false: timing is not a PTP time scale
true: timing is a PTP time scale.
<timesource>: [0..255] Time source.
16 (0x10) ATOMIC_CLOCK
32 (0x20) GPS
48 (0x30) TERRESTRIAL_RADIO
64 (0x40) PTP
80 (0x50) NTP
96 (0x60) HAND_SET
144 (0x90) OTHER
160 (0xA0) INTERNAL_OSCILLATOR
PTP PortDataSet
Description:
Set or show PTP port data set.
Syntax:
PTP PortDataSet <clockinst> [<port_list>] [<announceintv>] [<announceto>] [<syncintv>] [<delaymech>] [<minpdelayreqintv>]
[<delayasymmetry>] [<ingressLatency>] [<egressLatency>]
Parameters:
<clockinst>: clock instance number [0..3]
<port_list>: Port list or 'all', default: All ports
<announceintv>: [-3..4] Log2 of mean announce interval in sec.
<announceto>: [-1..10] Log2 of announce receipt timeout in sec.
<syncintv>: [-7..4] Log2 of sync interval in sec.
<delaymech>: The delaymech parameter takes the following values:
e2e: The port is configured to use the delay request-response mechanism
p2p: The port is configured to use the peer delay mechanism
545