User Manual

Table Of Contents
User’s Manual of IGS-10080MFT
0 - 7: The range of Priorities ptp can use in the tagged frames
PTP ClockDelete
Description:
Delete a PTP clock instance.
Syntax:
PTP ClockDelete <clockinst> [<devtype>]
Parameters:
<clockinst>: clock instance number [0..3]
<devtype> : The devtype parameter takes the following values:
ord: Ordinary/Boundary clock
p2p: Peer-to-peer transparent clock
e2e: End-to-end transparent clock
mst: Master only clock
slv: Slave only clock
(default: Show actual init parameters)
PTP DefaultDS
Description:
Set or show PTP clock Default Data set priority1 and priority2 are used in the best master clock algorithm. Lower values
take precedence.
Syntax:
PTP DefaultDS <clockinst> [<priority1>] [<priority2>] [<domain>]
Parameters:
<clockinst>: clock instance number [0..3]
<priority1>: [0..255] Clock priority 1 for PTP BMC algorithm
<priority2>: [0..255] Clock Priority 2 for PTP BMC algorithm
<domain>: [0..127] PTP clock domain id (0 = default) for PTP
543