Industrial L2+ 8-Port Gigabit 802.
Table of Contents 1. Package Contents........................................................................................ 3 2. Requirements.............................................................................................. 4 3. Wiring the Power Inputs............................................................................... 5 4. Terminal Setup............................................................................................ 7 4.1 Logging on to the Console......................
1. Package Contents Thank you for purchasing PLANET L2+ Industrial Managed Gigabit PoE Switch, such as IGS-10020PT and IGS-10020HPT. The descriptions of these models are as follows: IGS-10020PT/ IGS-10020HPT: Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch “Industrial Managed PoE+ Switch” mentioned in this Quick Installation Guide refers to the above models. Open the box of the Industrial Managed PoE+ Switch and carefully unpack it.
2. Requirements zz Workstations running Windows XP/2003/Vista/7/8/10/2008, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols. zz Workstations are installed with Ethernet NIC (Network Interface Card) zz Serial Port Connection (Terminal) The above Workstations come with COM Port (DB9) or USB-to-RS232 converter. The above Workstations have been installed with terminal emulator, such as Hyper Terminal included in Windows XP/2003.
3. Wiring the Power Inputs The Upper Panel of the Industrial Managed PoE+ Switch indicates a DC inlet power socket and consists of one terminal block connector within 6 contacts. Please follow the steps below to insert the power wire. 1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2.
2. Tighten the wire-clamp screws for preventing the wires from loosening. 1 2 V1+ V1Power 1 IGS-10020PT/IGS-10020HPT Note 6 3 4 5 6 V2+ V2Power 2 Positive (+) Pin Negative (-) Pin Pin 1 / 5 Pin 2 / 6 The wire gauge for the terminal block should be in the range from 12 to 24 AWG.
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed PoE+ Switch. The console port of the Industrial Managed PoE+ Switch is DCE already, so that you can connect the console port directly through PC without the need of null modem. IGS Industrial Managed Switch PC/Workstation with Terminal emulation software IP Address: 192.168.0.
4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed PoE+ Switch and the terminal will display “running testing procedures”. Note The following console screen is based on the IGS-10020HPT. The display of the IGS-10020PT is the same as that of the IGS10020HPT. When the following dialog box shown in Figure 4-3 appears, please enter the factory default user name “admin” and password “admin”.
4.2 Configuring IP Address The Industrial Managed PoE+ Switch is shipped with default IP address shown below: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Industrial Managed PoE+ Switch, please use the procedure as follows: Display of the current IP Address 1. At the “#” prompt, enter “show ip interface brief”. 2. The screen displays the current IP address shown in Figure 4-4.
Configuration of the IP Address 3. At the “#” prompt, enter the following command and press as shown in Figure 4-5. The previous command would apply the following settings for the Industrial Managed PoE+ Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Figure 4-5: Configuring IP Address Screen 4. Repeat step 1 to check if the IP address has changed.
Store the current switch configuration 5. At the “#” prompt, enter the following command and press . # copy running-config startup-config Figure 4-6: Saving Current Configuration Command Screen If the IP is successfully configured, the Industrial Managed PoE+ Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed PoE+ Switch through the new IP address.
5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed PoE+ Switch. Note the Industrial Managed PoE+ Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed PoE+ Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.
Note The following web screen based on IGS-10020HPT will be the same as that of IGS-10020PT. 3. After entering the password, the main screen appears as shown in Figure 5-3. Figure 5-3: Web Main Screen of Industrial Managed PoE+ Switch The Switch Menu on the top of the Web page lets you access all the commands and statistics the Industrial Managed PoE+ Switch provides.
Figure 5-6: Switch Menu – Switching Figure 5-7: Switch Menu -- QoS Figure 5-8: Switch Menu -- Maintenance 14
Figure 5-9: Switch Menu -- Security Figure 5-10: Switch Menu -- PoE Figure 5-11: Switch Menu – Ring 15
Figure 5-12: Switch Menu – ONVIF Note If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description. Now, you can use the Web management interface to continue the Switch management or manage the Switch by console interface. Please refer to the user’s manual for more. 5.2.
3. Or the other way to save the setting is to Click Maintenance, Save Startup Config.
6. Recovering Back to Default Configuration To reset the IP address to the default IP address “192.168.0.100” and the user password to factory default mode (default password is admin), press the hardware-based reset button on the front panel for about 10 seconds. After the device is rebooted, you can login the management Web interface within the same subnet of 192.168.0.xx and default password. Be noted that all the previous setups will be disappeared after the factory default reset is made.
7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: http://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw IGS-10020PT/IGS-10020HPT User’s Manual: https://www.planet.com.