User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web page
- 4.2 System
- 4.2.1 Management
- 4.2.1.1 System Information
- 4.2.1.2 IP Configuration
- 4.2.1.3 IP Status
- 4.2.1.4 Users Configuration
- 4.2.1.5 Privilege Levels
- 4.2.1.6 NTP Configuration
- 4.2.1.6.1 System Time Correction Manually
- 4.2.1.7 Time Configuration
- 4.2.1.8 UPnP
- 4.2.1.9 DHCP Relay
- 4.2.1.10 DHCP Relay Statistics
- 4.2.1.11 CPU Load
- 4.2.1.12 System Log
- 4.2.1.13 Detailed Log
- 4.2.1.14 Remote Syslog
- 4.2.1.15 SMTP Configuration
- 4.2.1.16 Fault Alarm
- 4.2.1.17 Digital Input/Output
- 4.2.2 Simple Network Management Protocol
- 4.2.3 RMON
- 4.2.4 DHCP server
- 4.2.5 Industrial Protocol
- 4.2.1 Management
- 4.3 Switching
- 4.3.1 Port Management
- 4.3.2 Link Aggregation
- 4.3.3 VLAN
- 4.3.3.1 VLAN Overview
- 4.3.3.2 IEEE 802.1Q VLAN
- 4.3.3.3 VLAN Port Configuration
- 4.3.3.4 VLAN Membership Status
- 4.3.3.5 VLAN Port Status
- 4.3.3.6 Private VLAN
- 4.3.3.7 Port Isolation
- 4.3.3.8 VLAN setting example:
- 4.3.3.8.1 Two Separate 802.1Q VLANs
- 4.3.3.8.2 VLAN Trunking between two 802.1Q aware switches
- 4.3.3.8.3 Port Isolate
- 4.3.3.9 MAC-based VLAN
- 4.3.3.10 IP Subnet-based VLAN Membership Configuration
- 4.3.3.11 Protocol-based VLAN
- 4.3.3.12 Protocol-based VLAN Membership
- 4.3.4 Spanning Tree Protocol
- 4.3.5 Multicast
- 4.3.6 MLD Snooping
- 4.3.7 MVR (Multicast VLAN Registration)
- 4.3.8 LLDP
- 4.3.9 MAC Address Table
- 4.3.10 Loop Protection
- 4.3.11 UDLD
- 4.3.12 GVRP
- 4.3.13 PTP
- 4.4 Quality of Service
- 4.5 Security
- 4.6 Ring
- 4.7 ONVIF
- 4.8 Maintenance
- 5. SWITCH OPERATION
- 6. TROUBLESHOOTING
- APPENDIX A: Networking Connection
- APPENDIX B : GLOSSARY
User’s Manual of IGS series
50
MGB-TLA10(V2)
MGB-
TLB10(V2)
YES
1000 WDM(LC) Single Mode 10km 1310nm 1550nm
-40 ~ 75 ℃
1000 WDM(LC) Single Mode 10km 1550nm 1310nm
-40 ~ 75 ℃
MGB-TLA20
MGB-TLB20
YES
1000 WDM(LC) Single Mode 20km 1310nm 1550nm
-40 ~ 75 ℃
1000 WDM(LC) Single Mode 20km 1550nm 1310nm
-40 ~ 75 ℃
MGB-TLA40
MGB-TLB40
YES
1000 WDM(LC) Single Mode 40km 1310nm 1550nm
-40 ~ 75 ℃
1000 WDM(LC) Single Mode 40km 1550nm 1310nm
-40 ~ 75 ℃
MGB-TLA80
MGB-TLB80
YES
1000 WDM(LC) Single Mode 80km 1490nm 1550nm
-40 ~ 75 ℃
1000 WDM(LC) Single Mode 80km 1550nm 1490nm
-40 ~ 75 ℃
1. It is recommended to use PLANET SFP on the Industrial L2+ Managed Switch
. If you
insert an SFP/SFP+ transceiver that is not supported, the Industrial L2+ Managed Switch
will not recognize it.
2. Please choose the SFP/SFP+ transceiver which can be operated under -40~75
degrees C
temperature if the switch device is working in a 0~50 degrees C temperature environment.
Connect the fiber cable
1. Attach the duplex LC connector on the network cable to the SFP transceiver.
2. Connect the other end of the cable to a device – switches with SFP installed, fiber NIC on a workstation or a media
converter.
3. Check the LNK/ACT LED of the SFP slot on the front of the Industrial L2+ Managed Switch. Ensure that the SFP
transceiver is operating correctly.