10 and 100 Mbps ports will be linked down while running cable diagnostic. Therefore, running cable diagnostic on a 10 or 100
Mbps management port will cause the switch to stop responding until VeriPHY is complete. The VeriPHY Cable Diagnostics
screen in Figure 4-8-2-4 appears.
Figure 4-8-2-4 VeriPHY Cable Diagnostics Page Screenshot
The page includes the following fields:
Object Description
Port
The port where you are requesting Cable Diagnostics.
Description
Display per port description.
Cable Status
Port:
Port number.
Pair:
The status of the cable pair.
OK - Correctly terminated pair
Open - Open pair
Short - Shorted pair
Short A - Cross-pair short to pair A
Short B - Cross-pair short to pair B
Short C - Cross-pair short to pair C
Short D - Cross-pair short to pair D
Cross A - Abnormal cross-pair coupling with pair A