User's Manual
8
2.4 Switch Upper Panel
The upper panel of the Industrial PoE+ Switch consists of one terminal block
connector within two DC power inputs.
Figure 2-2 shows the upper panel of the Industrial PoE+ Switch.
PWR1
PWR2
Fault
DC Input:
48-56V , 5.5A max.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
Figure 2-2: Industrial PoE+ Switch Upper Panel
2.5 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial PoE+ Switch
is used for two DC redundant power inputs. Please follow the steps below to insert
the power wire.
When performing any of the procedures like inserting the wires or
tightening the wire-clamp screws, make sure the power is OFF to
prevent from getting an electric shock.
1. Insert positive and negative DC power wires into Contacts 1 and 2 for Power 1,
or Contacts 5 and 6 for Power 2.
PWR1
PWR2
Fault
DC Input:
48-56V , 5.5A max.
Max. fault loading: 24V, 1A
1 2 3 4 5 6