ICS-Series User Manual

Users Manual of ICS-11x Serial Device Server Series
45
4.5.1 Serial setup
The serial setup screen is shown in Figure 4-5-2.
Figure 4-5-2: Serial Setup Page Screenshot
Object Description
Description
Used to distinguish the name of each serial port. It allows 1 to 15 characters (e.g. A-Z,
a-z, 0-9)
Baud Rate
The rate of data transmission to and from the attached serial device. It allows 50 bps to
921600 bps. The default is 921600 bps.
Stop Bits
The stop bit follows the data and parity bits in serial communication. It indicates the end
of transmission. The default is 1.
Data Bits
Indicates the number of the bits in a transmitted data package. The allowed value is
5,6,7,8 and default value is 8.
Parity
This parameter controls the error checking mode. It support five modes and default
value is none.
Even
Odd
None
Space
Mark
Interface
The device server supports three interfaces. The default value is RS-232.
RS-232
RS-422
RS-485 2-Wire
RS-485 4-Wire
Flow Control
The method is used to suspend and resume data transmission to ensure that data is not
lost. It supports four methods and default value is none.
None
RTS/CTS
Xon/Xoff
DTR/DSR