Datasheet
ICS-120
2
Remote Management
As the ICS-120 provides easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed
efciently via its Web, telnet, and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection,
which saves the administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices. Multiple connection
options are available for a large networking environment as well.
ICS-120
Serial Device Server
TCP/IP
Remote Management
Web Browser
VCOM Utility
Telnet
RJ45
LNK/ACT 100
Reset
5V , 2A max.
UserName: admin
Password: ******
*Corporation : PLANET
*Model :
*MAC Address : A8:F7:E0:22:00:01
*Firmware Version : v.1.181227_620
*Ethernet IP Address : 192.168.0.100
Main Menu
[1] Basic
[2] Accessible IP
[3] Network
[4] Serial
[5] SNMP
[6] Change password
[7] Load factory default
[s] Save and Restart
[q] Quit
Enter your choice
Access Control System – Traditional System Application
Most of the enterprises and government use access control plate and Mifare or RFID to authorize entrance identity. Traditionally, the access control machines
use RS232 or RS485 serial interface with their cables connecting to login server. By applying the ICS-120 Serial Device Server, the access control machine
is able to extend the network over longer distances via Ethernet interfaces. In addition, the ICS-120 can be linked to an xDSL router to get the internet
access capability so that the access control can be set and monitored over the internet.
Applications
11F
B1F
Administration Department
Account
Authentication Server
Ethernet Switch
Access
Control
ICS-115A
ICS-120
100BASE-TX UTP
Serial Line (RS-XXX)
|O|O|
I/O
Access
Control
100BASE-FX Fiber Optic
100
100
I/O
Access
Control
I/O
Process Control
To monitor, configure and manage the robotic conveyer including other production machines, PLC (programmable logical control) is required to drive the
above manufacturing process. The ICS-120 can be set to the TCP server mode and connected to the PLC. Thus, the administrator can congure and set
command settings through Fast Ethernet intranet to remotely control the PLC, without having to stand by the I/O machine.